Thermal-hydraulic evaluation of passive containment cooling system of improved APR+ during LOCAs

被引:0
|
作者
Jeon, Byong Guk [1 ]
No, Hee Cheon [1 ]
机构
[1] Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Yuseong-gu, Daejeon 305-701, Korea, Republic of
基金
新加坡国家研究基金会;
关键词
Cooling systems - Heat resistance - Pressurized water reactors - Tubes (components) - Thermoelectric equipment - Tanks (containers) - Mixtures - Heat exchangers - Steam condensers - Cooling - Steam condensate;
D O I
暂无
中图分类号
学科分类号
摘要
Various reactor concepts and technologies have been devised and evaluated to ensure the integrity of the core and the containment under a prolonged station blackout. After the successful validation of the passive auxiliary feedwater system (PAFS) of Advanced Power Reactor Plus (APR+), Korea is considering an improved APR+ with a passive containment cooling system (PCCS). In a previous paper, we suggested a PCCS design based on APR+ and performed a scoping analysis. We performed a MARS simulation for the thermal hydraulic evaluation of the system behavior, including natural circulation through the Passive Condensation Cooling Tank (PCCT) water pool and inside PCCS tubes as well as steam-air mixture condensation inside the containment. Through a simulation using the MARS system code, we investigated the effect of air holdup tanks (AHTs) on reduction of the air fraction in the containment, the effects of several steam-air mixture condensation models, the role of heat structures, and the flow instability inside the PCCS tubes. We found that the presence of AHT reduced the number of required PCCS tubes by more than half and the heat resistance of the steam-air mixture side is dominant in terms of governing the overall performance of PCCS. The embedded MARS condensation model and Uchida's correlation gave lower heat transfer coefficients than Dehbi's correlation, and heat structures removed more decay heat than PCCS tubes. Finally, intense flow instability inside the PCCS tubes was observed and was mitigated by placing orifice plates at the inlet of the PCCS tubes, increasing the height of the return nozzle, or increasing the tube angle. © 2014 Elsevier B.V.
引用
收藏
页码:190 / 198
相关论文
共 50 条
  • [1] Thermal-hydraulic evaluation of passive containment cooling system of improved APR plus during LOCAs
    Jeon, Byong Guk
    No, Hee Cheon
    NUCLEAR ENGINEERING AND DESIGN, 2014, 278 : 190 - 198
  • [2] Thermal-hydraulic tests on passive containment cooling system of advanced PWR
    Tan, Shu-Shi
    Leng, Gui-Jun
    Cheng, Xu
    Ni, Yong-Jun
    Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (SUPPL.): : 30 - 33
  • [3] Thermal-hydraulic Analysis of Passive Containment Cooling System of HPR1000
    Qiu J.
    Wu J.
    Tian W.
    Wang Z.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (01): : 72 - 80
  • [4] THERMAL-HYDRAULIC R&DS FOR THE APR+ DEVELOPMENTS IN KOREA
    Song, Chul-Hwa
    Kwon, Tae-Soon
    Yun, Byong-Jo
    Choi, Ki-Yong
    Kim, Hwan-Yeol
    Jun, Hyung-Gil
    Kim, Han-Gon
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 4 PTS A AND B, 2011, : 823 - +
  • [5] Thermal-hydraulic investigation of a proposed concept for a passive containment cooling system and evaluation of heat exchanger performance
    Ilyas, Muhammad
    Hengra, Nasir H.
    Nauman, Muhammad D.
    Samee, Abdus
    Inayat, Mansoor H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (02) : 320 - 340
  • [6] Experimental study on transient thermal-hydraulic characteristics of an open natural circulation for the passive containment cooling system
    Hui, Kai
    Chen, Weixiong
    Li, Shaodan
    Zhao, Quanbin
    Yan, Junjie
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 179
  • [7] Influence of Passive Containment Cooling System on containment thermal hydraulic transients during a postulated severe accident
    Adinarayana, K. N., V
    Ali, Seik Mansoor
    PROGRESS IN NUCLEAR ENERGY, 2021, 142
  • [8] Thermal-hydraulic phenomena and heat removal performance of a passive containment cooling system according to exit loss coefficient
    Lim, Sun Taek
    Kim, Koung Moon
    Kang, Jun-young
    Kim, Taewan
    Jerng, Dong-Wook
    Ahn, Ho Seon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (10) : 4077 - 4086
  • [9] Conceptual design of passive containment cooling system with air holdup tanks in the concrete containment of improved APR
    Jeon, Byong Guk
    No, Hee Cheon
    NUCLEAR ENGINEERING AND DESIGN, 2014, 267 : 180 - 188
  • [10] Coupling characteristics of thermal-hydraulic power and passive a containment heat removal system in a containment vessel during the loss of coolant accident
    Chu W.
    Cong J.
    Li W.
    Zhang N.
    Meng Z.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (07): : 1104 - 1111