A prediction method of strength deterioration in aging of circular steel tube corroded in marine environment

被引:0
|
作者
Fujii K.
Hashimoto K.
Watanabe E.
Itoh Y.
Sugiura K.
Nogami I.
Nagata K.
Nakamura H.
机构
关键词
Axial compressive strength; Corrosion; Cylindrical steel column; Strength deterioration;
D O I
10.2208/jsceja.66.92
中图分类号
学科分类号
摘要
This paper presents a future prediction method of strength deterioration of circular steel column corroded along with aging in marine environment. Corroded surfaces along with aging are made by the two models. One model makes surface unevenness caused by corrosion progress and the other expresses deterioration of paint to prevent rust. And based on the corroded surface made by the models, the remaining strength after a passing period can be predicted by FEM analyses or other formulae evaluating the strength. It is concluded from results that the prediction method proposed herein is persuasive enough to express the actual phenomena of corrosion and can predict the compressive strength of circular steel tube along with aging.
引用
收藏
页码:92 / 105
页数:13
相关论文
共 50 条
  • [31] Compressive strength of circular hollow reinforced concrete confined by an internal steel tube
    Han, Taek Hee
    Yoon, Ki Yong
    Kang, Young Jong
    CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (09) : 1690 - 1699
  • [32] Composite response of high-strength concrete confined by circular steel tube
    McAteer, P
    Bonacci, JF
    Lachemi, M
    ACI STRUCTURAL JOURNAL, 2004, 101 (04) : 466 - 474
  • [33] Time-dependent reliability of corroded circular steel tube structures: Characterization of statistical models for material properties
    Jiang, Yanju
    Song, Biao
    Hu, Jiyue
    Liang, Hongjun
    Rao, Shu
    STRUCTURES, 2021, 33 : 792 - 803
  • [34] Enhanced Analytical Method of Predicting Residual Strength Capacities of Corroded Steel Bridge Plates
    Appuhamy, J. M. R. S.
    Ohga, M.
    Chun, P.
    Furukawa, S.
    Dissanayake, P. B. R.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2713 - 2720
  • [35] Evaluation of Fracture Strength of Corroded Steel Bolted Joints Using Acoustic Emission Method
    Matsuo, Takuma
    Tokuhara, Koya
    Zairyo to Kankyo/ Corrosion Engineering, 2022, 71 (07): : 213 - 217
  • [36] Flexural behavior of high strength concrete filled square steel tube with inner CFRP circular tube
    Zhijian Yang
    Guochang Li
    Yan Lang
    Chen Fang
    KSCE Journal of Civil Engineering, 2017, 21 : 2728 - 2737
  • [37] Flexural behavior of high strength concrete filled square steel tube with inner CFRP circular tube
    Yang, Zhijian
    Li, Guochang
    Lang, Yan
    Fang, Chen
    KSCE JOURNAL OF CIVIL ENGINEERING, 2017, 21 (07) : 2728 - 2737
  • [38] Eccentric compression behavior of concrete-encased-and-filled steel tube columns with high-strength circular steel tube
    Lee, Ho-Jun
    Park, Hong-Gun
    Choi, In-Rak
    THIN-WALLED STRUCTURES, 2019, 144
  • [39] Prediction of ductility factor of corroded reinforced concrete beams exposed to long term aging in chloride environment
    Vu Hiep Dang
    Francois, Raoul
    CEMENT & CONCRETE COMPOSITES, 2014, 53 : 136 - 147
  • [40] Numerical studies on CFRP strengthened steel circular members under marine environment
    Kabir, M. H.
    Fawzia, S.
    Chan, T. H. T.
    Badawi, M.
    MATERIALS AND STRUCTURES, 2016, 49 (10) : 4201 - 4216