Evaluation of the cooling effectiveness of air-cooled data centers by energy diagram

被引:0
|
作者
机构
[1] Li, Nan
[2] Li, Haowei
[3] Duan, Kaiwen
[4] Tao, Wen-Quan
关键词
D O I
10.1016/j.apenergy.2024.125215
中图分类号
学科分类号
摘要
Data centers are one of the world's largest energy consumers, and their cooling systems contribute to the majority of the total energy consumption. Although some studies have suggested evaluation metrics, the cooling capacity utilization in the computer room of air-cooled data centers is still not able to be directly quantified. In this paper, the dimensionless index Effective Cooling Ratio (ECR) is proposed for the first time to evaluate the energy efficiency of the cooling process in air-cooled data centers. By decoupling the cooling process of the computer room, the energy diagram is developed to analyze the thermal energy changes of each phase. Moreover, the proving of this approach is carried out with computational fluid dynamics simulation; three data center models are investigated, and the results demonstrate the good performance of the enclosed aisle. This metric not only provides a valuable tool for quantifying the cooling and energy performance within data centers but also suggests ways to improve the energy efficiency of data centers. © 2024
引用
收藏
相关论文
共 50 条
  • [1] ENERGY MODELING OF AIR-COOLED DATA CENTERS: PART II THE EFFECT OF RECIRCULATION ON THE ENERGY OPTIMIZATION OF OPEN-AISLE, AIR-COOLED DATA CENTERS
    Demetriou, Dustin W.
    Khalifa, H. Ezzat
    PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 395 - 404
  • [2] Cooling architecture selection for air-cooled Data Centers by minimizing exergy destruction
    Gupta, Rohit
    Asgari, Sahar
    Moazamigoodarzi, Hosein
    Pal, Souvik
    Puri, Ishwar K.
    ENERGY, 2020, 201
  • [3] COOLING EFFECTIVENESS OF MIST PRECOOLER FOR IMPROVING ENERGY PERFORMANCE OF AIR-COOLED CHILLER
    Yu, Fu Wing
    Chan, Kwok Tai
    Yang, Jia
    Sit, Rachel Kam Yung
    THERMAL SCIENCE, 2018, 22 (01): : 193 - 204
  • [4] Development of an Outdoor Air Cooling-Type Air-Cooled Package Air Conditioner for Data Centers
    Udagawa, Yosuke
    Sekiguchi, Keisuke
    Yanagi, Masahide
    Uekusa, Tsuneo
    Naito, Yasuhiro
    ASHRAE TRANSACTIONS 2013, VOL 119, PT 1, 2013, 119 : 167 - 175
  • [5] Workload management for air-cooled data centers: An energy and exergy based approach
    Gupta, Rohit
    Moazamigoodarzi, Hosein
    MirhoseiniNejad, SeyedMorteza
    Down, Douglas G.
    Puri, Ishwar K.
    ENERGY, 2020, 209
  • [6] Evaluation of air-cooled solar absorption cooling systems
    Kim, DS
    Machielsen, CHM
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 117 - 123
  • [7] Field test of cooling systems in two air-cooled data centers: Various regions, air distributions and evaporative cooling technologies
    Jing, Yang
    Xie, Linfeng
    Li, Fangling
    Zhan, Ziyang
    Wang, Zhenghua
    Yang, Fan
    Fan, Jiale
    Zhu, Zihan
    Zhang, Hao
    Zhao, Ce
    Shi, Zhuofan
    Jiang, Haihua
    Xie, Xiaoyun
    Jiang, Yi
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [8] Comprehensive energy and economic assessment of CRAH bypass method in air-cooled data centers
    Erden, Hamza Salih
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [9] Influence of cooling air jets on the aerodynamic and aerothermal losses and cooling effectiveness of air-cooled radial flameholder
    Chen, Yuqian
    Fan, Yuxin
    Han, Qixiang
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 172
  • [10] Retrofitting of an air-cooled data center for energy efficiency
    Kuzay, Mustafa
    Dogan, Aras
    Yilmaz, Sibel
    Herkiloglu, Oguzhan
    Atalay, Ali Serdar
    Cemberci, Atilla
    Yilmaz, Cagatay
    Demirel, Ender
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 36