Lightning Impulse Pollution Flashover Characteristics and Model of 10 kV Composite Arrester Combined Insulator

被引:0
|
作者
Xinhan, Qiao [1 ]
Zhijin, Zhang [2 ]
Zhenglong, Jiang [3 ]
Xingliang, Jiang [2 ]
Guohui, Pang [2 ]
机构
[1] School of Electrical Engineering China University of Mining and Technology, Xuzhou,221008, China
[2] State Key Laboratory of Power Transmission Equipment Technology Chongqing University, Chongqing,400044, China
[3] Disaster Prevention & Reduction Center of State Grid Hunan Electric Power Co. Ltd Changsha, 410007, China
关键词
Bioremediation - Flashover - Groundwater pollution - Insulating materials - Insulation - Insulator contamination - Lightning arresters - Seebeck effect - Wavelet transforms;
D O I
10.19595/j.cnki.1000-6753.tces.230899
中图分类号
学科分类号
摘要
引用
收藏
页码:6932 / 6940
相关论文
共 50 条
  • [41] Space Electric Field Characteristics of Silicone Rubber Insulator Pollution Flashover and Its Application in Flashover Prewarning
    Zhang, Dongdong
    Xu, Hong
    Huang, Xiaoning
    Zhang, Zhijin
    Jiang, Xingliang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (01) : 439 - 448
  • [42] A Study on Flashover Characteristics of Supporting Insulators in SF6 under Lightning Impulse
    Qin, Yifan
    Wen, Tao
    Zhao, Junping
    Ma, Jingtan
    Li, Yuan
    Wang, Tonglei
    Li, Jinzhong
    Zhang, Qiaogen
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 604 - 607
  • [43] Equivalence of pollution simulation methods for AC flashover performance of iced composite insulator
    Jiang, Xing-Liang
    Zhang, Zhi-Jin
    Hu, Jian-Lin
    Yang, Jian-Lan
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (13): : 115 - 120
  • [44] Flashover Characteristics of Spacers in SF6/N2-Filled under Composite Voltage of DC and Lightning Impulse
    Wang Y.
    Ma G.
    Zhou H.
    Lu S.
    Li C.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (14): : 3084 - 3092
  • [45] DC pollution flashover model and its validation of polluted insulator strings
    Zhang, Zhijin
    Jiang, Xingliang
    Sun, Caixin
    Hu, Jianlin
    Yuan, Jihe
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (04): : 36 - 41
  • [46] Pollution flashover performance of short sample for 750kV composite insulators
    Jiang, XL
    Hu, JL
    Liang, Y
    Shu, LC
    Xie, SJ
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 312 - 315
  • [47] Experimental Research on Residual Voltage Characteristics of 10kV Entire Arrester Under 8/20 μs Impulse Current
    Yu Wenbo
    Cai Li
    Wang Jianguo
    Fan Yadong
    Xiao Yutong
    Zou Xin
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [48] Oscillatory switching impulse flashover characteristics of insulator strings under normal weather conditions
    Jayaraju, M
    Nair, PSC
    Prabhakar, BR
    Reddy, BS
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2003, 31 (02) : 171 - 188
  • [49] Effect of inverted T arrangement on AC pollution flashover characteristics of insulator strings
    Jiang, Xingliang
    Ren, Xiaodong
    Wang, Han
    Han, Xingbo
    Bi, Conglai
    Li, Zhiyu
    Hou, Ledong
    HIGH VOLTAGE, 2019, 4 (02) : 97 - 104
  • [50] Pollution Flashover Characteristics of Insulator Strings with Inverted T-type Arrangement
    Jiang X.
    Wang H.
    Yang Z.
    Han X.
    Wu H.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (03): : 701 - 707