Characterization of an external electro-optic sampling probe: Influence of probe height on distortion of measured voltage pulses

被引:0
|
作者
Seitz, S. [1 ]
Bieler, M. [1 ]
Hein, G. [1 ]
Pierz, K. [1 ]
Siegner, U. [1 ]
Schmückle, F.J. [2 ]
Heinrich, W. [2 ]
机构
[1] Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Germany
[2] Ferdinand-Braun-Institut für Hochfrequenztechnik, Gustav-Kirchhoff-Strasse 4, D-12489 Berlin, Germany
来源
Journal of Applied Physics | 2006年 / 100卷 / 11期
关键词
We experimentally and theoretically investigate the distortion that an external electro-optic sampling tip imprints on a measured voltage pulse that propagates along a coplanar stripline. By using the electro-optic effect of the GaAs substrate on which the stripline is fabricated we obtain the undisturbed voltage pulse; which serves as a reference pulse. This allows us to quantitatively compare the voltage pulse measured with the external electro-optic sampling tip to the undisturbed voltage pulse. The sensitivity of the sampling measurement and the distortion of the voltage pulse are determined for different heights of the tip which is lifted off the stripline. The experimental data agree very well with numerical finite difference calculations. We find that small changes of the tip height already influence the measurements strongly. From the experiments we infer an optimum working height of the sampling tip of only 0.5 μm. Our investigations help to improve the accuracy of electro-optic sampling measurements. © 2006 American Institute of Physics;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [31] Details of electro-optic terahertz detection with a chirped probe pulse
    Yellampalle, B.
    Kim, K. Y.
    Rodriguez, G.
    Glownia, J. H.
    Taylor, A. J.
    OPTICS EXPRESS, 2007, 15 (03): : 1376 - 1383
  • [32] Sensitivity improvement of an electro-optic high-impedance probe
    Shinagawa, M
    Nagatsuma, T
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 865 - 869
  • [33] Electro-optic Bdot probe measurement of magnetic fluctuations in plasma
    Saitoh, H.
    Nishiura, M.
    Nakazawa, T.
    Morikawa, J.
    Yoshida, Z.
    Osawa, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (10):
  • [34] Sensitivity improvement of an electro-optic high-impedance probe
    Shinagawa, M
    Nagatsuma, T
    Miyazawa, S
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (01) : 235 - 239
  • [35] Failure diagnosis of organic photovoltaic using electro-optic probe
    Jun Katsuyama
    Kazuki Matsumoto
    Ryo Sugiyama
    Shinya Hasegawa
    Mitsuru Shinagawa
    Yoshiki Yanagisawa
    Optical Review, 2014, 21 : 621 - 627
  • [36] Failure Diagnosis of Organic Photovoltaic Using Electro-Optic Probe
    Katsuyama, Jun
    Matsumoto, Kazuki
    Sugiyama, Ryo
    Hasegawa, Shinya
    Shinagawa, Mitsuru
    Yanagisawa, Yoshiki
    OPTICAL REVIEW, 2014, 21 (05) : 621 - 627
  • [37] Fabry-Perot enhancement of external electro-optic sampling
    Univ of Essex, Colchester, United Kingdom
    Opt Quantum Electron, 6 (661-669):
  • [38] Fabry–Pe´rot enhancement of external electro-optic sampling
    A. J. VICKERS
    R. TESSER
    R. DUDLEY
    M. A. HASSAN
    Optical and Quantum Electronics, 1997, 29 : 661 - 669
  • [39] Proton-bombarded GaP external electro-optic sampling
    Zhang, Daming
    Tian, Xiaojian
    Sun, Wei
    Li, Dehui
    Yi, Maobin
    Pan Tao Ti Hsueh Pao/Chinese Journal of Semiconductors, 2000, 21 (09): : 918 - 921
  • [40] Fabry-Perot enhancement of external electro-optic sampling
    Vickers, AJ
    Tesser, R
    Dudley, R
    Hassan, MA
    OPTICAL AND QUANTUM ELECTRONICS, 1997, 29 (06) : 661 - 669