Analysis and Design of Biplanar Coils Within Magnetic Shielding Room Considering Actual Ferromagnetic Boundaries

被引:0
|
作者
Xu, Xueping [1 ]
Liu, Yi [1 ]
Sun, Xin [1 ]
Zhou, Weiyong [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Coils; Magnetic shielding; Permeability; Mirrors; Magnetic resonance imaging; Magnetometers; Magnetic noise; Toroidal magnetic fields; Analytical models; Reflection; Biplane coil; magnetic shielding room (MSR); target field method (TFM); variable permeability and thickness image method (PT-IM); FIELD;
D O I
10.1109/JSEN.2024.3488002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The target field is often distorted by coupling effects of the active magnetic compensation coil and magnetic shielding material in the magnetic shielding room (MSR). The permeability and thickness of the magnetic shielding layer are assumed infinite in existing image methods (IMs), which will generate large errors considering actual ferromagnetic boundaries. A novel method for designing high-uniformity biplane coil within MSR is presented. First, the effects of all image points are considered. A variable permeability and thickness IM (PT-IM) is proposed and an analytical model of the coil inside the ferromagnetic boundary is established. Second, a linear decreasing weight particle swarm optimization (LDW-PSO) algorithm is applied to optimize the coil parameters. The simulation results indicate that the proposed PT-IM and target field method (TFM) (PT-IM&TFM) lowers the maximum field deviations of the ${B}_{\text {x}}$ , ${B}_{\text {y}}$ , and ${B}_{\text {z}}$ uniform field coils by 30.82%, 37.86%, and 35% in the target region, respectively, compared to IM&TFM. The experimental results indicate that the actual maximum magnetic field deviation decreases by 40.01% and 32.48% for the ${B}_{\text {x}}$ and $\textit {dB}_{\text {x}}/\textit {dz}$ coils, respectively. The results verify the effectiveness and practicality of this method in compensating for the residual magnetic field of MSR.
引用
收藏
页码:40623 / 40633
页数:11
相关论文
共 50 条
  • [21] Design and FEM analyses of solenoidal coils and magnetic shielding of 1-MJ SMES
    Zhang, GJ
    Wang, ZJ
    Cui, X
    IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (03) : 1273 - 1276
  • [22] Research on the Design Method of Gradient Magnetic Field Coil Based on the Magnetic Shielding Room
    Jin, Chongyu
    Pan, Donghua
    Chen, Yitao
    Lin, Shengxin
    Wang, Yiding
    Li, Liyi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [23] Design of highly uniform three-dimensional square magnetic field coils for external magnetic shielding of magnetometers
    Li, Yang
    Xu, Jun
    Kang, Xiangyu
    Fan, Zhengkun
    Dong, Xiangmei
    Gao, Xiumin
    Zhuang, Songlin
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 331
  • [24] Design of Biplanar Excitation Magnetic Field Coils With Small-Size and Large Uniform Area in Near-Zero Magnetic Cell Incubator
    Zhao, Xiuqi
    Zhang, Lu
    Zhang, Xu
    Dou, Shuai
    Yang, Jianzhi
    Zheng, Shiqiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [25] Design of Magnetic Shielding and Field Coils for a TES X-ray Microcalorimeter Test Platform
    Miniussi, Antoine R.
    Adams, Joseph S.
    Bandler, Simon R.
    Chervenak, James A.
    Datesman, Aaron M.
    Doriese, William B.
    Eckart, Megan E.
    Finkbeiner, Fred M.
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick S.
    Sadleir, John E.
    Sakai, Kazuhiro
    Smith, Stephen J.
    Wakeham, Nicholas A.
    Wassell, Edward J.
    van Weers, Henk J.
    Yoon, Wonsik
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2019, 194 (5-6) : 433 - 442
  • [26] Design of Magnetic Shielding and Field Coils for a TES X-ray Microcalorimeter Test Platform
    Antoine R. Miniussi
    Joseph S. Adams
    Simon R. Bandler
    James A. Chervenak
    Aaron M. Datesman
    William B. Doriese
    Megan E. Eckart
    Fred M. Finkbeiner
    Richard L. Kelley
    Caroline A. Kilbourne
    Frederick S. Porter
    John E. Sadleir
    Kazuhiro Sakai
    Stephen J. Smith
    Nicholas A. Wakeham
    Edward J. Wassell
    Henk J. van Weers
    Wonsik Yoon
    Journal of Low Temperature Physics, 2019, 194 : 433 - 442
  • [27] Multichannel Magnetic Stimulation System Design Considering Mutual Couplings among the Stimulation Coils
    Korean Electrotech. Res. Institute, Kyungki, Korea, Republic of
    不详
    1600, 812-817 (May 2004):
  • [28] Multichannel magnetic stimulation system design considering mutual couplings among the stimulation coils
    Han, BH
    Chun, IK
    Lee, SC
    Lee, SY
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (05) : 812 - 817
  • [29] FE Analysis of Magnetic Shielding Screens based on Mortars containing Ferromagnetic particles
    Laudani, Antonino
    Lozito, Gabriele Maria
    Coco, Salvatore
    Pollicino, Giuseppe
    2015 IEEE 1ST INTERNATIONAL FORUM ON RESEARCH AND TECHNOLOGIES FOR SOCIETY AND INDUSTRY (RTSI 2015) PROCEEDINGS, 2015,
  • [30] Ferromagnetic Design of Coils Considering Misalignment Effects for a SAE J2954-Compliant EV Wireless Charger
    Casaucao, Inmaculada
    Trivino, Alicia
    Delgado, Alberto
    IEEE ACCESS, 2024, 12 : 163978 - 163987