A study on the electrical fire risk assessment methods of LED lightings for outdoor

被引:0
|
作者
Kim H.-K.
Kim D.-O.
Choi H.-S.
机构
关键词
Abnormal voltage; Dielectric breakdown; Electric fire; Led lighting; Poor contact; Short circuit;
D O I
10.5370/kiee.2011.60.3.674
中图分类号
学科分类号
摘要
In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts (connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.
引用
收藏
页码:620 / 624
页数:4
相关论文
共 50 条
  • [21] Uncertainties in Fire Risk Assessment
    Teng Jinping
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 158 - 162
  • [22] Rapid fire risk assessment
    Gillett, JE
    HAZARDS XVI: ANALYSING THE PAST, PLANNING THE FUTURE, 2001, (148): : 337 - 349
  • [23] Fire risk assessment of cleanrooms
    Yun, Yeo-Song
    Song, Yun-Suk
    Lee, Young-soon
    Kim, Sung-Min
    Hyun, Seong-Ho
    Yoon, Myong-O
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 889 - 895
  • [24] Risk assessment methods: Chloroform as a case study
    Andersen, ME
    Robinson, DE
    MICROBIAL PATHOGENS AND DISINFECTION BY-PRODUCTS IN DRINKING WATER: HEALTH EFFECTS AND MANAGEMENT OF RISKS, 2000, : 351 - 364
  • [25] A study of shadowing on indoor visible-light wireless communication utilizing plural white LED lightings
    Komine, T
    Nakagawa, M
    1ST INTERNATIONAL SYMPOSIUM ON WIRELESS COMMUNICATION SYSTEMS 2004, PROCEEDINGS, 2004, : 36 - 40
  • [26] Case Study: Conducting a Risk Assessment for an Electrical Utility
    Covert, Edwin
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON CYBER WARFARE AND SECURITY ICCWS, 2023, : 49 - 56
  • [27] A Study of Shadowing on Indoor Visible-Light Wireless Communication Utilizing Plural White LED Lightings
    Toshihiko Komine
    Shinichiro Haruyama
    Masao Nakagawa
    Wireless Personal Communications, 2005, 34 : 211 - 225
  • [28] ADVANCES IN ASSESSMENT METHODS FOR FIRE SAFETY
    WILLIAMSON, RB
    DEMBSEY, NA
    FIRE SAFETY JOURNAL, 1993, 20 (01) : 15 - 38
  • [29] A Survey of Electrical Fire Causes Assessment Technology
    Thai, Hong-Danh
    Le, Ngoc-Bao-Van
    Lee, Daesung
    Huh, Jun-Ho
    IEEE ACCESS, 2024, 12 : 145378 - 145392
  • [30] FIRE PERFORMANCE STANDARDS AND THE PROBLEM OF FIRE RISK ASSESSMENT
    HARMATHY, TZ
    FIRE AND MATERIALS, 1980, 4 (04) : 173 - 176