Evaluation of overhead transmission lines operation based on grey relation correlation

被引:0
|
作者
Han, Fu-Chun [1 ]
Zhou, Lin-Wei [1 ]
Jia, Lei-Liang [2 ]
Zhou, Guo-Hua [2 ]
机构
[1] School of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan 030024, China
[2] Shanxi Electric Power Company, Taiyuan 030001, China
来源
Gaodianya Jishu/High Voltage Engineering | 2009年 / 35卷 / 02期
关键词
Electric lines;
D O I
暂无
中图分类号
学科分类号
摘要
To achieve the scientific maintenances for overhead transmission lines and the security of operation state of overhead transmission lines, the grey relation method was used to analyze hierarchy process for overhead transmission lines, and an operation theory comprehensive evaluation model was established. According to the constitute components of overhead transmission lines, 5 kinds of characteristic relation evaluation object factor sets were defined , the typical grey relation evaluation object factor sets and the partner factor were chosen , and optimum grey relational constitute components were ascertained. Moreover, grey relational coefficients about all kinds of chosen components were comfirmed by the grey correlation theory, the facter weight was calculated by the analytic hierarchy process, and grey relational coefficients were calculated by the grey relational coefficients matrix multiplying facter weight matrix. Finally, the correlation was used to analyze and comprehensively evaluate. Good results can be achieved on the basis of the calculation and analysis of the actual overhead transmission lines. It is indicated that the grey relation method can examine and repair overhead transmission lines job according to actual overhead transmission lines operation state in progress, and may economize large amount of manpower and financial resources.
引用
收藏
页码:399 / 402
相关论文
共 50 条
  • [41] Overhead Quasi-Coaxial Transmission Lines
    Trainotti, Valentino
    Fano, Walter G.
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2009, 51 (06) : 93 - 101
  • [42] LATE DISCUSSION OF PROPAGATION ON OVERHEAD TRANSMISSION LINES
    PERZ, MC
    USHIROZA.M
    MCELROY, AJ
    BARTHOLD, LO
    HEDMAN, DE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (06): : 489 - &
  • [43] Contactless voltage sensor for overhead transmission lines
    Chen, Kun-Long
    Guo, Yi
    Ma, Xiaoyu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (04) : 957 - 966
  • [44] Analytical Description of Overhead Transmission Lines Loadability
    Lauria, Davide
    Mottola, Fabio
    Quaia, Stefano
    ENERGIES, 2019, 12 (16)
  • [45] Transient Fault Analysis in Overhead Transmission Lines
    Parsi, Mahmood
    Crossley, Peter A.
    2018 53RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2018,
  • [46] Icing Detector for Overhead Power Transmission Lines
    Moser, Michael J.
    George, Boby
    Zangl, Hubert
    Brasseur, Georg
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1078 - 1082
  • [47] Galloping of overhead transmission lines in gusty wind
    Ohkuma, T
    Marukawa, H
    WIND AND STRUCTURES, 2000, 3 (04) : 243 - 253
  • [48] Probabilistic Ampacity Forecasting for Overhead Transmission Lines
    Konstantinou, Theodoros
    Savvopoulos, Nikolaos
    Hatziargyriou, Nikos
    2019 2ND INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES (SEST 2019), 2019,
  • [49] Zero sequence impedance of overhead transmission lines
    Horak, John
    2006 59TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2006, : 182 - 192
  • [50] ROBOTIC MAINTENANCE OF OVERHEAD TRANSMISSION LINES.
    Dunlap, John H.
    Van Name, Joseph M.
    Henkener, Jerry A.
    IEEE Transactions on Power Delivery, 1986, PWRD-1 (03) : 280 - 284