Design and Control of a Cable-Driven Exoskeleton System for Upper-Extremity Rehabilitation

被引:1
|
作者
Chen, Zhiquan [1 ]
Wu, Jiyuan [1 ]
Ju, Chunqi [1 ]
Wang, Xingsong [1 ]
Tian, Mengqian [1 ]
Liu, Bin [2 ]
机构
[1] Southeast Univ, Sch Mech Engn, Nanjing 211189, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
来源
IEEE ACCESS | 2024年 / 12卷
基金
中国国家自然科学基金;
关键词
Exoskeletons; Cables; Kinematics; Actuators; Stroke (medical condition); Robots; Elbow; Cable shielding; Shoulder; Mechanical cables; Upper-extremity exoskeleton; cable actuation; motion control strategy; human-robot interaction; rehabilitation training; STROKE; ARM; THERAPY;
D O I
10.1109/ACCESS.2024.3515141
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Stroke rehabilitation with the assistance of exoskeleton robots has the potential to facilitate the recovery of motor skills by guiding, supporting, and encouraging movement in the affected limbs. In this work, an upper-extremity exoskeleton actuated by the cable transmission mechanism, was developed for rehabilitation training of stroke patients. The exoskeleton is designed with three DOFs, including shoulder abduction/adduction, shoulder flexion/extension, and elbow flexion/extension. The main body of exoskeleton is comprised of three links and two cuffs, with a total weight of approximately 1.7 kg. Based on the mechanical design and cable arrangement, the kinematics and dynamics of the actuation cables were analyzed. In addition, a PID-based position control strategy and an impedance control strategy were designed based on the cable kinematics and dynamics. To investigate the application performance in passive motion assistance, a prototype of the cable-driven exoskeleton system was established, and the corresponding experiments were conducted with five subjects. In position control experiments, the measured joint trajectories exhibit similar variation trends and close peek angles to the demonstration trajectory, which is the main emphasis in rehabilitation scenarios. Meanwhile, it can be inferred that the time lag is the primary reason for the tracking error between the expected and measured trajectories. As to the impedance control experiments, the statistical results indicate that the employment of lower impedance parameters tends to protect the human-robot interaction safety by sacrificing the tracking accuracy of joint position.
引用
收藏
页码:187964 / 187975
页数:12
相关论文
共 50 条
  • [21] Cable driven exoskeleton for upper-limb rehabilitation: A design review
    Sanjuan, J. D.
    Castillo, A. D.
    Padilla, M. A.
    Quintero, M. C.
    Gutierrez, E. E.
    Sampayo, I. P.
    Hernandez, J. R.
    Rahman, M. H.
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2020, 126
  • [22] Cable-Driven Flexible Exoskeleton Robot for Abnormal Gait Rehabilitation
    Xu Z.
    Xie L.
    Journal of Shanghai Jiaotong University (Science), 2022, 27 (02) : 231 - 239
  • [23] Velocity Control of an Upper-Limb Cable-Driven Rehabilitation Robot
    Li, Xianming
    Yang, Qianqian
    Song, Rong
    2018 IEEE INTERNATIONAL CONFERENCE ON CYBORG AND BIONIC SYSTEMS (CBS), 2018, : 559 - 563
  • [24] Robust control of a cable-driven rehabilitation robot for lower and upper limbs
    Seyfi, Niloufar Sadat
    Khalaji, Ali Keymasi
    ISA TRANSACTIONS, 2022, 125 : 268 - 289
  • [25] A Resistance Compensation Control Algorithm for a Cable-Driven Hand Exoskeleton for Motor Function Rehabilitation
    Wang, Shuang
    Li, Jiting
    Zheng, Ruoyin
    INTELLIGENT ROBOTICS AND APPLICATIONS, PT II, 2010, 6425 : 398 - 404
  • [26] Design of a Rotational Hydro-Elastic Actuator for an Active Upper-Extremity Rehabilitation Exoskeleton.
    Stienen, Arno H. A.
    Hekman, Edsko E. G.
    ter Braak, Huub
    Aalsma, Arthur M. M.
    van der Helm, Frans C. T.
    van der Kooij, Herman
    2008 2ND IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB 2008), VOLS 1 AND 2, 2008, : 969 - +
  • [27] A cable-driven exosuit for upper limbs: design, control, and evaluation
    Shi, Yongjun
    Gao, Yongzhuo
    Lin, Weiqi
    He, Long
    Mao, Xiwang
    Long, Yi
    Dong, Wei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (20) : 9810 - 9824
  • [28] Dynamics and Control of a 4-dof Wearable Cable-driven Upper Arm Exoskeleton
    Brackbill, Elizabeth A.
    Mao, Ying
    Agrawal, Sunil K.
    Annapragada, Madhu
    Dubey, Venkatesh N.
    ICRA: 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-7, 2009, : 2308 - +
  • [29] Modelling and control of an upper extremity exoskeleton for rehabilitation
    Taha, Zahari
    Majeed, Anwar P. P. Abdul
    Tze, Mohd Yashim Wong Paul
    Hashem, Mohammed Abdo
    Khairuddin, Ismail Mohd
    Razman, Mohd Azraai Mohd
    2ND INTERNATIONAL MANUFACTURING ENGINEERING CONFERENCE AND 3RD ASIA-PACIFIC CONFERENCE ON MANUFACTURING SYSTEMS (IMEC-APCOMS 2015), 2016, 114
  • [30] Development of Upper-extremity Exoskeleton driven by Pneumatic Cylinder toward Robotic Rehabilitation Platform for Shoulder Elevation
    Noda, Tomoyuki
    Morimoto, Jun
    PROCEEDINGS OF THE IEEE/RAS-EMBS INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR 2015), 2015, : 496 - 501