Design and Control of a Cable-Driven Exoskeleton System for Upper-Extremity Rehabilitation

被引:1
|
作者
Chen, Zhiquan [1 ]
Wu, Jiyuan [1 ]
Ju, Chunqi [1 ]
Wang, Xingsong [1 ]
Tian, Mengqian [1 ]
Liu, Bin [2 ]
机构
[1] Southeast Univ, Sch Mech Engn, Nanjing 211189, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
来源
IEEE ACCESS | 2024年 / 12卷
基金
中国国家自然科学基金;
关键词
Exoskeletons; Cables; Kinematics; Actuators; Stroke (medical condition); Robots; Elbow; Cable shielding; Shoulder; Mechanical cables; Upper-extremity exoskeleton; cable actuation; motion control strategy; human-robot interaction; rehabilitation training; STROKE; ARM; THERAPY;
D O I
10.1109/ACCESS.2024.3515141
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Stroke rehabilitation with the assistance of exoskeleton robots has the potential to facilitate the recovery of motor skills by guiding, supporting, and encouraging movement in the affected limbs. In this work, an upper-extremity exoskeleton actuated by the cable transmission mechanism, was developed for rehabilitation training of stroke patients. The exoskeleton is designed with three DOFs, including shoulder abduction/adduction, shoulder flexion/extension, and elbow flexion/extension. The main body of exoskeleton is comprised of three links and two cuffs, with a total weight of approximately 1.7 kg. Based on the mechanical design and cable arrangement, the kinematics and dynamics of the actuation cables were analyzed. In addition, a PID-based position control strategy and an impedance control strategy were designed based on the cable kinematics and dynamics. To investigate the application performance in passive motion assistance, a prototype of the cable-driven exoskeleton system was established, and the corresponding experiments were conducted with five subjects. In position control experiments, the measured joint trajectories exhibit similar variation trends and close peek angles to the demonstration trajectory, which is the main emphasis in rehabilitation scenarios. Meanwhile, it can be inferred that the time lag is the primary reason for the tracking error between the expected and measured trajectories. As to the impedance control experiments, the statistical results indicate that the employment of lower impedance parameters tends to protect the human-robot interaction safety by sacrificing the tracking accuracy of joint position.
引用
收藏
页码:187964 / 187975
页数:12
相关论文
共 50 条
  • [1] Design and Control of a Cable-Driven Upper Limb Exoskeleton Robot for Rehabilitation
    Ju, Chunqi
    Chen, Zhiquan
    Qin, Hao
    Wang, Xingsong
    Tian, Mengqian
    2023 29TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE, M2VIP 2023, 2023,
  • [2] A Cable Driven Upper Arm Exoskeleton for Upper Extremity Rehabilitation
    Mao, Ying
    Agrawal, Sunil K.
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011,
  • [3] Modeling and Design of a Spring-loaded, Cable-driven, Wearable Exoskeleton for the Upper Extremity
    Zhou, Lelai
    Bai, Shaoping
    Andersen, Michal Skipper
    Rasmussen, John
    MODELING IDENTIFICATION AND CONTROL, 2015, 36 (03) : 167 - 177
  • [4] Mechatronics design and testing of a cable-driven upper limb rehabilitation exoskeleton with variable stiffness
    Li, Zhongyi
    Li, Wang
    Chen, Wei-Hai
    Zhang, Jianbin
    Wang, Jianhua
    Fang, Zaojun
    Yang, Guilin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (02):
  • [5] Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation
    Mao, Ying
    Agrawal, Sunil Kumar
    IEEE TRANSACTIONS ON ROBOTICS, 2012, 28 (04) : 922 - 931
  • [6] Design of a 6 DOF Cable-Driven Upper Limb Exoskeleton
    Ai, Letian
    Zhou, Tianlin
    Wu, Lei
    Qian, Wei
    Xiao, Xiaohui
    Guo, Zhao
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2021, PT I, 2021, 13013 : 728 - 736
  • [7] Design and control of a cable-driven rehabilitation robot for upper and lower limbs
    Oyman, Efe Levent
    Korkut, Muhammed Yusuf
    Ylmaz, Cuneyt
    Bayraktaroglu, Zeki Y.
    Arslan, M. Selcuk
    ROBOTICA, 2022, 40 (01) : 1 - 37
  • [8] Design on the Bowden Cable-Driven Upper Limb Soft Exoskeleton
    Wei, Wei
    Qu, Zhicheng
    Wang, Wei
    Zhang, Pengcheng
    Hao, Fuchun
    APPLIED BIONICS AND BIOMECHANICS, 2018, 2018
  • [9] CURER: A Lightweight Cable-Driven Compliant Upper Limb Rehabilitation Exoskeleton Robot
    Qian, Wei
    Liao, Junbei
    Lu, Linjun
    Ai, Letian
    Li, Miao
    Xiao, Xiaohui
    Guo, Zhao
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2023, 28 (03) : 1730 - 1741
  • [10] A cable-driven elbow exoskeleton with variable stiffness actuator for upper limb rehabilitation
    Yang, Lei
    Zhang, Fuhai
    Fu, Yili
    ROBOTICA, 2024,