Laser doppler anemometer measurements of the flow in the impeller blade channels of a centrifugal blood pump

被引:0
|
作者
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore [1 ]
机构
来源
Hong Kong Inst Eng Trans | 2008年 / 4卷 / 11-16期
关键词
Centrifugal blood pump - Experimental rigs - Flow similarities - Impeller passage - Incomplete similarity - Laser Doppler anemometers - Numerical simulation studies - Rotary blood pumps;
D O I
暂无
中图分类号
学科分类号
摘要
Hemodynamics in the rotary blood pumps is of great importance for it is highly related to the blood hemolysis and thrombus generation in the blood pumps. In the present study, the flow in the impeller passages of Kyoto-NTN centrifugal blood pump with 16 forward-bending blades was measured using Laser Doppler Anemometer (LDA) ona 1:1 size pump model. The measurement results were compared with those of the numerical simulation study and the measurement results on a 5:1 enlarged pump model. The comparison indicated a reasonable agreement between the results of the present measurement and the numerical simulation. The comparison between the measurement results on the 1:1 and 5:1 enlarged pump models revealed, however, significant differences in the flow patterns. The main cause of the differences between the 1:1 and 5:1 pump model should be due to the incomplete similarity of the later, which has produced 31 % higher dimensionless flow rate than the prototype. Therefore, it is important to require more elaborate arrangements of experimental rig to enhance the flow similarity of the enlarged pump model or, considering the difficulties in achieving the complete similarity of the enlarged pump, the measurements can be suggested to be carried on the pump model that has the same size as the prototype.
引用
收藏
相关论文
共 50 条
  • [41] LASER-DOPPLER INVESTIGATION OF THE FLOW INSIDE A BACKSWEPT, CLOSED, CENTRIFUGAL IMPELLER
    ADLER, D
    LEVY, Y
    JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1979, 21 (01): : 1 - 6
  • [42] OPEN-CHANNEL FLOW MEASUREMENTS WITH A LASER DOPPLER ANEMOMETER - DISCUSSION
    BATHURST, JC
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1987, 113 (12): : 1570 - 1572
  • [43] LASER DOPPLER ANEMOMETER MEASUREMENTS OF PULSATILE FLOW IN A MODEL CAROTID BIFURCATION
    KU, DN
    GIDDENS, DP
    JOURNAL OF BIOMECHANICS, 1987, 20 (04) : 407 - 421
  • [44] Large eddy simulation of the flow energy dissipation in the blade channels of a stalled pump impeller
    Zhu, Di
    Tao, Ran
    Xiao, Ruofu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (06) : 1227 - 1235
  • [45] Improvement of washout flow in a centrifugal blood pump by a semi-open impeller
    Tsukiya, T.
    Taenaka, Y.
    Tatsumi, E.
    Takano, H.
    ASAIO Journal, 2000, 46 (02)
  • [46] Improvement of washout flow in a centrifugal blood pump by a semi-open impeller
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2002, 48 (01) : 76 - 82
  • [47] Measurements of rotating stall inside a centrifugal pump impeller
    Johnson, D. A.
    Pedersen, N.
    Jacobsen, C. B.
    Proceedings of the ASME Fluids Engineering Division Summer Conference - 2005, Vol 1, Pts A and B, 2005, : 1281 - 1288
  • [48] TURBULENCE MEASUREMENTS IN A CENTRIFUGAL PUMP WITH A SYNCHRONOUSLY ORBITING IMPELLER
    FLACK, RD
    MINER, SM
    BEAUDOIN, RJ
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1992, 114 (02): : 350 - 359
  • [49] Flow in a centrifugal pump impeller at design and off-design conditions - Part I: Particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) measurements
    Pedersen, N
    Larsen, PS
    Jacobsen, CB
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (01): : 61 - 72
  • [50] CFD Simulation of Centrifugal Pump with Different Impeller Blade Trailing Edges
    Li, Hui
    Chen, Yongjun
    Yang, Yang
    Wang, Shixin
    Bai, Ling
    Zhou, Ling
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2023, 11 (02)