Polystyrene microsphere-based immunochromatographic assay for detection of aflatoxin b1 in maize

被引:0
|
作者
Wang J. [1 ]
Li X. [1 ]
Shen X. [1 ]
Zhang A. [2 ]
Liu J. [1 ]
Lei H. [1 ,3 ]
机构
[1] Guangdong Provincial Key Laboratory of Food Quality and Safety, South China Agricultural University, Guangzhou
[2] Technology Center of Qinhuangdao Customs, Qinhuangdao
[3] Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou
来源
Biosensors | 2021年 / 11卷 / 06期
基金
中国国家自然科学基金;
关键词
Aflatoxin B[!sub]1[!/sub; Immunochromatographic assay; Maize; Polystyrene microspheres;
D O I
10.3390/BIOS11060200
中图分类号
学科分类号
摘要
Aflatoxin B1 (AFB1 ), a mycotoxin, is hepatotoxic, carcinogenic, and nephrotoxic in humans and animals, and contaminate a wide range of maize. In this study, an immunochromatographic assay (ICA) based on polystyrene microspheres (PMs) was developed for sensitive and quantitative detection of AFB1 in maize. The amounts of PMs, the condition for activating carboxyl groups of PMs, the amount of monoclonal antibody (mAb), and the volume of the immune probe were optimized to enhance the performance PMs-ICA for point-of-care testing of AFB1 in maize. The PMs-ICA showed the cut-off value of 1 ng/mL in phosphate buffer (PB) and 6 µg/kg in maize samples, respectively. The quantitative limit of detection (qLOD) was 0.27 and 1.43 µg/kg in PB and maize samples, respectively. The accuracy and precision of the PMs-ICA were evaluated by analysis of spiked maize samples with recoveries of 96.0% to 107.6% with coefficients of variation below 10%. In addition, the reliability of PMs-ICA was confirmed by the liquid chromatography-tandem mass spectrometry method. The results indicated that the PMs-ICA could be used as a sensitive, simple, rapid point-of-care testing of AFB1 in maize. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
引用
收藏
相关论文
共 50 条
  • [31] An aptamer-based dipstick assay for the rapid and simple detection of aflatoxin B1
    Shim, Won-Bo
    Kim, Min Jin
    Mun, Hyoyoung
    Kim, Min-Gon
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 288 - 294
  • [32] Aflatoxin b1 in verification of maize contamination
    Vallone, Lisa
    Dragoni, Ivan
    Rodriguez, Paola
    CULTURA CIENTIFICA, 2010, (08): : 71 - 74
  • [33] Development of One-step Simultaneous Immunochromatographic Assay for Rapid Analysis of Aflatoxin B1 and Ochratoxin A
    Shim, Won-Bo
    Kim, Gyeongyeol
    Ryu, Hee-Jung
    Nam, Minji
    Chung, Duck-Hwa
    FOOD SCIENCE AND BIOTECHNOLOGY, 2009, 18 (03) : 641 - 648
  • [34] Development of novel monoclonal antibodies-based ultrasensitive enzyme-linked immunosorbent assay and rapid immunochromatographic strip for aflatoxin B1 detection
    Liu, Jiun-Wei
    Lu, Chuan-Chen
    Liu, Biing-Hui
    Yu, Feng-Yih
    FOOD CONTROL, 2016, 59 : 700 - 707
  • [35] Screening of Aptamers for Aflatoxin B1 and Establishment of a Method for Aflatoxin B1 Detection
    Zhang M.
    Zhang X.
    Li C.
    Gao H.
    Liu J.
    Tian Y.
    Ma W.
    Li Y.
    Tan J.
    Shipin Kexue/Food Science, 2020, 41 (24): : 295 - 303
  • [36] A novel microsphere-based fluorescence immunochromatographic assay for monitoring cefalexin residues in plasma, milk, muscle and liver
    Bian, Sumin
    Chu, Xiaogang
    Jin, Yong
    Xing, Shige
    Zhang, Yue
    Hu, Hongbo
    ANALYTICAL METHODS, 2013, 5 (22) : 6441 - 6448
  • [37] Development of a Microsphere-Based Fluorescence Immunochromatographic Assay for Monitoring Lincomycin in Milk, Honey, Beef, and Swine Urine
    Zhou, Jie
    Zhu, Kui
    Xu, Fei
    Wang, Wenjun
    Jiang, Haiyang
    Wang, Zhanhui
    Ding, Shuangyang
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (49) : 12061 - 12066
  • [38] Detection of aflatoxin B1 by ELISA
    Ghai, J. Kapur
    Sodhi, S.
    INDIAN VETERINARY JOURNAL, 2007, 84 (10): : 1104 - 1105
  • [39] Rapid detection of Escherichia coli O157:H7 by a fluorescent microsphere-based immunochromatographic assay and immunomagnetic separation
    Li, Qianru
    Yang, Yuexi
    Hu, Fei
    Cai, Yanxue
    Liu, Xiaoyun
    He, Xiaowei
    ANALYTICAL BIOCHEMISTRY, 2019, 564 : 32 - 39
  • [40] Microsphere-based immunoassay for the detection of azaspiracids
    Rodriguez, Laura P.
    Vilarino, Natalia
    Carmen Louzao, M.
    Dickerson, Tobin J.
    Nicolaou, K. C.
    Frederick, Michael O.
    Botana, Luis M.
    ANALYTICAL BIOCHEMISTRY, 2014, 447 : 58 - 63