3D brain anomaly tissues detection simulation based on magnetic resonance electrical impedance tomography

被引:0
|
作者
Yan, Dandan [1 ]
Shen, Shengyuan [1 ]
Chen, Hui [1 ]
机构
[1] College of Information Engineering, China Jiliang University, Hangzhou,310018, China
来源
基金
中国国家自然科学基金;
关键词
Image reconstruction - Electric impedance - Tissue - Optimization - Evolutionary algorithms - Three dimensional computer graphics - Electric impedance tomography - Magnetic resonance imaging - Electric impedance measurement - Magnetic flux;
D O I
10.13336/j.1003-6520.hve.2015.04.040
中图分类号
学科分类号
摘要
In order to overcome the difficulty of rotating imaging objects in the operation of magnetic resonance imaging (MRI) system, we proposed an algorithm for three-dimensional magnetic resonance electrical impedance tomography (MREIT) by the differential evolution theory. This algorithm was verified by using a three-dimensional realistic-geometry head model and single-direction magnetic-flux-density measured data. The results show that the proposed algorithm can reconstruct the impedance image of diseased realistic-geometry head model. The error between the calculated value and theoretical value is less than 5%; this indicates high imaging precision and high spatial resolution of the proposed algorithm. By improving factors in real time that fits the algorithm better, it is able to shorten the reconstruction time and accelerate the algorithm convergence. It is concluded that the improved algorithm has good convergence and high imaging quality, and it has potential in clinical applications. ©, 2015, Science Press. All right reserved.
引用
收藏
页码:1372 / 1376
相关论文
共 50 条
  • [21] Low-parametric Induced Current - Magnetic Resonance Electrical Impedance Tomography for Quantitative Conductivity Estimation of Brain Tissues using A Priori Information: A Simulation Study
    De Geeter, Nele
    Crevecoeur, Guillaume
    Dupre, Luc
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5669 - 5672
  • [22] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [23] On Denoising Technology in Magnetic Resonance Electrical Impedance Tomography
    Xie, Jiaye
    Liu, Jijun
    PROCEEDINGS OF FIRST INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION, VOL III: MODELLING AND SIMULATION IN ELECTRONICS, COMPUTING, AND BIO-MEDICINE, 2008, : 346 - 351
  • [24] Coregistration of electrical impedance tomography and magnetic resonance imaging
    Halter, R. J.
    Manwaring, P.
    Hartov, A.
    Paulsen, K. D.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 416 - 419
  • [25] Magnetic resonance electrical impedance tomography of the breast: A simulation study on basic imaging setup
    Lee, B. I.
    Oh, S. H.
    Kim, T. -S.
    Woo, E. J.
    Lee, S. Y.
    Kwon, O.
    Seo, J. K.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 4377 - 4380
  • [26] A DSP based multi-frequency 3D electrical impedance tomography system
    Goharian, Mehran
    Soleimani, Manuchehr
    Jegatheesan, Aravinthan
    Chin, Kenrick
    Moran, Gerald R.
    ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (09) : 1594 - 1603
  • [27] Biosensor Based on Electrical Impedance Tomography for 3D Cancer Cell Culture Imaging
    Claudel, Julien
    Mazerbourg, Sabine
    Lacroix, Victorine
    Bettenfeld, Remi
    Schlauder, Cyril
    Kourtiche, Djilali
    Flament, Stephane
    2023 IEEE SENSORS, 2023,
  • [28] A DSP Based Multi-Frequency 3D Electrical Impedance Tomography System
    Mehran Goharian
    Manuchehr Soleimani
    Aravinthan Jegatheesan
    Kenrick Chin
    Gerald R. Moran
    Annals of Biomedical Engineering, 2008, 36 : 1594 - 1603
  • [29] Neural network based approach for anomaly detection in the lungs region by electrical impedance tomography
    Minhas, AS
    Reddy, MR
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) : 489 - 502
  • [30] Image Reconstruction Based on the Anatomical Information for Magnetic Resonance Electrical Impedance Tomography
    Hao, Liling
    Xu, Lisheng
    Yang, Benqiang
    Li, Gang
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2016, 31 (06): : 700 - 705