Diesel soot mass calculation in real-time with a differential mobility spectrometer

被引:0
|
作者
Symonds, Jonathan P.R. [1 ]
Reavell, Kingsley St.J. [1 ]
Olfert, Jason S. [2 ]
Campbell, Bruce W. [1 ]
Swift, Stuart J. [2 ]
机构
[1] Cambustion Ltd., J6 Paddocks, 347 Cherry Hinton Road, Cambridge, CB1 8DH, United Kingdom
[2] Cambridge University Engineering Department, Trumpington Street, Cambridge, CB2 1PZ, United Kingdom
来源
| 1600年 / Elsevier Ltd卷 / 38期
关键词
This paper presents a methodology to allow a real-time particle size spectrometer to produce a mass concentration output by calculation from its electrical mobility response. As part of this; a Bayesian statistical algorithm for parametrising spectral data from the Cambustion DMS500 in terms of a number of lognormal functions is outlined; allowing the nucleation and accumulation modes of a Diesel aerosol to be treated separately and also to reduce mass calculation noise and improve spectral resolution. Previous literature is combined with new experimental results to develop a size:mass power-law relationship for this instrument. The effective density as a function of size for this instrument is found to be closer to that for water droplets than equivalent relationships for DMA/SMPS measurements in the literature; therefore making DMS500 mass calculation less susceptible to error from liquid adsorbed on agglomerates. The technique is validated with two Diesel engines against the gravimetric methods of filter paper and Diesel particulate filter (DPF) weighings. Good agreement is achieved over a variety of engine conditions; with the mean and standard deviation of the percentage difference of the calculated mass concentration from DPF weighings being - 12.1 ± 11.4 % and from filter paper weighings being - 15.1 ± 18.0 %. The calculated mass concentrations are systematically below those of the gravimetric methods. © 2006 Elsevier Ltd. All rights reserved;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [41] Comparative measurements of toxic industrial compounds with a differential mobility spectrometer and a time of flight ion mobility spectrometer
    Ungethuem, Bert
    Walte, Andreas
    Muenchmeyer, Wolf
    Matz, Gerhard
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2009, 12 (04) : 131 - 137
  • [42] Real-time supervision of diesel injection pumps
    Leonhardt, S.
    Isermann, R.
    MTZ Motortechnische Zeitschrift, 1996, 57 (02):
  • [43] Real-time mass spectrometry
    Thorsten Hoffmann
    Analytical and Bioanalytical Chemistry, 2003, 375 : 36 - 37
  • [44] Real-time mass spectrometry
    Hoffmann, T
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (01) : 36 - 37
  • [45] Differential ion mobility/MS/MS: When you need separations in real-time
    Glish, Gary L.
    Isenberg, Samantha
    Spencer, Sandra
    Santiago, Brandon
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [46] Chemical Effects in the Separation Process of a Differential Mobility/Mass Spectrometer System
    Schneider, Bradley B.
    Covey, Thomas R.
    Coy, Stephen L.
    Krylov, Evgeny V.
    Nazarov, Erkinjon G.
    ANALYTICAL CHEMISTRY, 2010, 82 (05) : 1867 - 1880
  • [47] FOLLOWING ENZYME CATALYSIS IN REAL-TIME INSIDE A FAST ATOM BOMBARDMENT MASS-SPECTROMETER
    SMITH, LA
    CAPRIOLI, RM
    BIOMEDICAL MASS SPECTROMETRY, 1983, 10 (02): : 98 - 102
  • [48] REAL-TIME ANALYSIS OF BREATH USING AN ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETER
    LOVETT, AM
    REID, NM
    BUCKLEY, JA
    FRENCH, JB
    CAMERON, DM
    BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (03): : 91 - 97
  • [49] Real-time etching process monitoring and end-point detection with a time-of-flight mass spectrometer
    Gasc, Sebastien
    Binda, Federico
    Das Kanungo, Pratyush
    Hofer, Lukas
    Rothenberger, Maximilian
    2024 35TH ANNUAL SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE, ASMC, 2024,
  • [50] Real-time measurement of oligomeric species in secondary organic aerosol with the aerosol time-of-flight mass spectrometer
    Gross, DS
    Gälli, ME
    Kalberer, M
    Prevot, ASH
    Dommen, J
    Alfarra, MR
    Duplissy, J
    Gaeggeler, K
    Gascho, A
    Metzger, A
    Baltensperger, U
    ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2130 - 2137