Biomechanical assessment of anterior plate system, bilateral pedicle screw and transdiscal screw system for high-grade spondylolisthesis: a finite element study

被引:0
|
作者
Dhar, Utpal K. [1 ]
Sultan, Hadi [2 ]
Aghayev, Kamran [3 ]
Tsai, Chi-Tay [1 ]
Vrionis, Frank D. [4 ]
机构
[1] Florida Atlantic Univ, Dept Ocean & Mech Engn, Boca Raton, FL USA
[2] Florida Atlantic Univ, Charles E Schmidt Coll Med, Boca Raton, FL USA
[3] BHT Clin, Istanbul, Turkiye
[4] Boca Raton Reg Hosp, Marcus Neurosci Inst, Dept Neurosurg, Boca Raton, FL 33486 USA
关键词
spondylolisthesis; finite element study; internal fixation technique; range of motion; interbody cage; LUMBAR SPINE; SURGICAL-TREATMENT; MECHANICAL-BEHAVIOR; LUMBOSACRAL SPINE; LOAD; DIRECTIONS; FIXATION;
D O I
10.3389/fbioe.2024.1491420
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction Limited information regarding the biomechanical evaluation of various internal fixation techniques for high-grade L5-S1 spondylolisthesis is available. The stiffness of the operated segment and stress on the hardware can profoundly influence clinical outcomes and patient satisfaction. The objective of this study was to quantitatively investigate biomechanical profiles of various fusion methods used for high-grade spondylolisthesis by using finite element (FE) analysis.Methods An FE lumbar spine model of healthy spine was developed based on a patient's CT scan. High-grade (III-IV) spondylolisthesis (SP model) was created by sliding L5 anteriorly and modifying L5-S1 facet joints. Three treatment scenarios were created by adding various implants to the model. These scenarios included L5-S1 interbody cage in combination with three different fixation methods-the anterior plate system (APS), bilateral pedicle screw system (BPSS), and transdiscal screw system (TSS). Range of motion (ROM), von Mises stress on cage, internal fixation as well as on the adjacent annuli were obtained and compared. The resistance to slippage was investigated by applying shear force on L5 vertebra and measuring its displacement regarding to S1.Results Under different loading conditions all treatment scenarios showed substantial reduction of ROM in comparison with SP model. No notable differences in ROM were observed between treatment models. There was no notable difference in cage stress among models. The von Mises stress on the internal fixation in the TSS model was less than in APS and BPSS. The TSS model demonstrated superior resistance to shear load compared to APS and BPSS. No discernible difference was observed between the SP, APS, BPSS, and TSS models when compared the ROM for adjacent level L4-L5. TSS's von Mises stress of the adjacent annulus was higher than in APS and BPSS.Conclusions The TSS model exhibited biomechanical superiority over the APS and BPSS models.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Transdiscal screw versus pedicle screw fixation for high-grade L5-S1 isthmic spondylolisthesis in patients younger than 60 years: a case–control study
    Isabel Collados-Maestre
    Alejandro Lizaur-Utrilla
    Teresa Bas-Hermida
    Esther Pastor-Fernandez
    Vicente Gil-Guillen
    European Spine Journal, 2016, 25 : 1806 - 1812
  • [2] Transvertebral interbody cage and pedicle screw fixation for high-grade spondylolisthesis - Case report
    Bozkus, H
    Dickman, CA
    JOURNAL OF NEUROSURGERY, 2004, 100 (01) : 62 - 65
  • [3] Transdiscal screw versus pedicle screw fixation for high-grade L5-S1 isthmic spondylolisthesis in patients younger than 60 years: a case-control study
    Collados-Maestre, Isabel
    Lizaur-Utrilla, Alejandro
    Bas-Hermida, Teresa
    Pastor-Fernandez, Esther
    Gil-Guillen, Vicente
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1806 - 1812
  • [4] Biomechanical Stability Before and After Graft Fusion with Unilateral and Bilateral Pedicle Screw Fixation: Finite Element Study
    Li, Jie
    Wang, Wenkai
    Zuo, Rui
    Zhou, Yue
    WORLD NEUROSURGERY, 2019, 123 : E228 - E234
  • [5] Biomechanical evaluation of a novel anterior transpedicular screw-plate system for anterior cervical corpectomy and fusion (ACCF): a finite element analysis
    Huang, Shengbin
    Ling, Qinjie
    Lin, Xinxin
    Qin, Hao
    Luo, Xiang
    Huang, Wenhua
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [6] Sacral osteotomy and single-stage posterior reduction with pedicle screw fixation in high-grade spondylolisthesis
    Min, Kan
    Liebscherr, Thomas
    Rothenfluh, Dominique
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 12S - 12S
  • [7] Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study
    Ambati, Divya V.
    Wright, Edward K., Jr.
    Lehman, Ronald A., Jr.
    Kang, Daniel G.
    Wagner, Scott C.
    Dmitriev, Anton E.
    SPINE JOURNAL, 2015, 15 (08): : 1812 - 1822
  • [8] Biomechanical analysis of a new bilateral pedicle screw fixator system based on topological optimization
    Li-Xin Guo
    Qing-Dong Wang
    International Journal of Precision Engineering and Manufacturing, 2020, 21 : 1363 - 1374
  • [9] Biomechanical analysis of a new bilateral pedicle screw fixator system based on topological optimization
    Guo, Li-Xin
    Wang, Qing-Dong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2020, 21 (07) : 1363 - 1374
  • [10] Biomechanical Evaluation of a Spinal Screw Fixation System by the Finite Element Method
    Paula Macedo, Ana
    Mardegan Issa, Joao Paulo
    Aparecido Defino, Helton Luiz
    Carlos Shimano, Antonio
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2015, 33 (01): : 318 - 326