Generation and adjustment of excitation pulse for calibration of high g accelerometer in hopkinson system

被引:0
|
作者
Fan, Jinbiao [1 ,2 ]
Xu, Peng [1 ,3 ]
Zu, Jing [1 ,2 ]
机构
[1] Science and Technology on Electronic Test & Measurement Laboratory, North University of China, Taiyuan,030051, China
[2] School of Computer and Control Engineering, North University of China, Taiyuan,030051, China
[3] School of Science, North University of China, Taiyuan,030051, China
关键词
Frequency response - Accelerometers - Bars (metal) - Calibration - Finite element method;
D O I
10.3901/JME.2015.06.093
中图分类号
学科分类号
摘要
In order to determine the duration of shock pulse exciting a high g accelerometer, a finite element method is used to simulate propagation of stress pulse and generation of acceleration pulse in a Hopkinson bar. The excitation pulse width is conformed for the calibration of shock sensitivity and frequency response characteristic of a high-g accelerometer. These excitation pulses are generated by using the corresponding collision component including projectile and adjusting pad. It is demonstrated that the excitation pulses with different duration can be generated in the same Hopkinson bar by changing the bullet shape of projectile and the material and thickness of adjusting pad to excite a high-g accelerometer for different calibration parameters. ©, 2015, Editorial Office of Chinese Journal of Mechanical Engineering. All right reserved.
引用
收藏
页码:93 / 97
相关论文
共 50 条
  • [1] Adjustment of the wave form of high g accelerometer using Hopkinson bar calibration system
    Fan, Jinbiao
    Xu, Peng
    Li, Qingfeng
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON SHOCK & IMPACT LOADS ON STRUCTURES, 2007, : 217 - +
  • [2] Numerical Simulation of Waveform Adjustment in high G Accelerometer Calibration System Using Hopkinson Bar
    Zhao Xing-liang
    Li Xin-liang
    Xu Peng
    Zhang Da-zhi
    PROCEEDINGS OF THE 2015 3RD INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND INFORMATION TECHNOLOGY APPLICATIONS, 2015, 35 : 182 - 190
  • [3] Measurement of exciting pulse for calibration of high-g accelerometer using lateral laser interferometer
    Fan, Jinbiao
    Li, Xi
    Xu, Peng
    Zu, Jing
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2015, 44 (02): : 497 - 502
  • [4] Characterization of triaxial piezoresistive high-g accelerometer by Hopkinson bar method
    Dong, Pei-Tao
    Li, Yuan
    Wu, Xue-Zhong
    Hou, Zhan-Qiang
    Xiao, Ding-Bang
    Qin, Jin-Gui
    Wang, Xiao-Feng
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (06): : 1473 - 1478
  • [5] Research of the experiment technique on the calibration for the high g accelerometer
    Li Yan
    Ma Tiehua
    Xu Peng
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 4119 - 4121
  • [6] Shock Calibration of the High-g Triaxial Accelerometer
    Wang, Yan
    Fan, Jinbiao
    Xu, Peng
    Zu, Jing
    Zhang, Zhijie
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 741 - 745
  • [7] Design, fabrication and calibration of a high-G MEMS accelerometer
    Shi, Yunbo
    Zhao, Yongqi
    Feng, Hengzhen
    Cao, Huiliang
    Tang, Jun
    Li, Jie
    Zhao, Rui
    Liu, Jun
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 : 733 - 742
  • [8] MEMS Accelerometer Calibration Denoising Method for Hopkinson Bar System Based on LMD-SE-TFPF
    Yan, Zeyu
    Hou, Boyang
    Zhang, Jingchun
    Shen, Chong
    Shi, Yunbo
    Tang, Jun
    Cao, Huiliang
    Liu, Jun
    IEEE ACCESS, 2019, 7 : 113901 - 113915
  • [9] Dynamic calibration method and system of ultra-high g accelerometer and piezoelectric force transducer
    Huang, J.
    Gu, J.
    Jiliang Xuebao/Acta Metrologica Sinica, 2001, 22 (04): : 300 - 304
  • [10] Quasi-Static Calibration Method of a High-g Accelerometer
    Wang, Yan
    Fan, Jinbiao
    Zu, Jing
    Xu, Peng
    SENSORS, 2017, 17 (02)