Seismic behavior of infill and nonstructural masonry walls strengthened with textile reinforced mortar

被引:0
|
作者
Zargaran, Mojdeh [1 ,2 ]
Attari, Nader K. A. [1 ,2 ]
Azadvar, Narges [1 ,2 ]
机构
[1] Rd Housing & Urban Dev Res Ctr BHRC, Dept Struct Engn, Composite Grp, Tehran, Iran
[2] Rd Housing & Urban Dev Res Ctr BHRC, Dept Struct Engn, Marvi St,Nargol St,Nextto ShahrakFarhangian,Sheikh, Tehran, Iran
关键词
Nonstructural elements; Nonstructural masonry wall; Textile reinforced mortar; Glass fabric connector; Out-of-plane behavior; Cyclic test; Seismic Behavior; Fabric connector; FRP REINFORCEMENT;
D O I
10.1016/j.conbuildmat.2024.139691
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents the results of cyclic tests conducted to evaluate the effects of textile reinforced mortar (TRM) on the behavior of infill and nonstructural masonry walls. The tests involved a combination of cyclic in-plane and out-of-plane loading to simulate conditions experienced during seismic events. Leca light cement blocks were used to construct all specimens. Two groups of walls-infill and non-structural-were assessed separately, with their cyclic behaviors, backbone curves, crack patterns, and failure modes compared. Glass fabric connectors were introduced to improve TRM performance by enhancing the bond between TRM and masonry wall. The findings indicate that reinforcing nonstructural walls just with angles is insufficient, as these walls failed under combined in-plane and out-of-plane forces. TRM strengthening, however, was effective in improving the cyclic behavior of the walls, increasing both in-plane and out-of-plane capacity and stiffness. The use of glass fabric connectors enhanced the in-plane lateral capacity and corresponding drift ratio by approximately 53 % and 36%, respectively, due to improved confinement and the connection between the TRM layers and masonry. These results underscore the potential of TRM with glass connectors as an effective strategy for enhancing the seismic performance of masonry walls. In addition, the results showed that non-structural walls do not affect the in-plane stiffness of the structure until a drift ratio of one percent, which is the separation amount between the wall and the structure. Comparison the results with codes reapproved that in-plane and out-of-plane capacities have interactional relationship.
引用
收藏
页数:24
相关论文
共 50 条
  • [11] Nonlinear analysis of masonry panels strengthened with textile reinforced mortar
    Basili, M.
    Marcari, G.
    Vestroni, F.
    ENGINEERING STRUCTURES, 2016, 113 : 245 - 258
  • [12] The Behavior of Masonry Walls with Reinforced Plaster Mortar
    Basaran, Hakan
    Demir, Ali
    Bagci, Muhiddin
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2013, 2013
  • [13] Shear-compression tests on stone masonry walls strengthened with basalt textile reinforced mortar (TRM)
    Meriggi, Pietro
    Caggegi, Carmelo
    Gabor, Aron
    de Felice, Gianmarco
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 316
  • [14] Cost-effective analysis of textile-reinforced mortar solutions used to reduce masonry infill walls collapse probability under seismic loads
    Furtado, Andre
    Rodrigues, Hugo
    Arede, Antonio
    Varum, Humberto
    STRUCTURES, 2020, 28 : 141 - 157
  • [15] Seismic behavior of hinged steel frames with masonry infill walls
    Yu, Qian-Qian
    Wu, Jie-Ying
    Gu, Xiang-Lin
    Wang, Lu
    JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [16] New formulation for predicting diagonal tension capacity of masonry brick walls strengthened with textile reinforced mortar (TRM)
    M. Shabdin
    M. Zargaran
    Nader K. A. Attari
    Materials and Structures, 2021, 54
  • [17] New formulation for predicting diagonal tension capacity of masonry brick walls strengthened with textile reinforced mortar (TRM)
    Shabdin, M.
    Zargaran, M.
    Attari, Nader K. A.
    MATERIALS AND STRUCTURES, 2021, 54 (02)
  • [18] Seismic evaluation of reinforced concrete structures infilled with masonry infill walls
    Abdelaziz M.M.
    Gomma M.S.
    El-Ghazaly H.
    Asian Journal of Civil Engineering, 2019, 20 (7) : 961 - 981
  • [19] Experimental diagonal tension (shear) test of Un-Reinforced Masonry (URM) walls strengthened with textile reinforced mortar (TRM)
    Shabdin, M.
    Zargaran, M.
    Attari, Nader K. A.
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 164 : 704 - 715
  • [20] Modelling the nonlinear behaviour of masonry walls strengthened with textile reinforced mortars
    Wang, X.
    Ghiassi, Bahman
    Oliveira, Daniel V.
    Lam, C. C.