Analysis and improvement on mal-operation of transformer backup protection

被引:0
|
作者
Yao, Chuang [1 ]
Li, Yongli [1 ]
Zhang, Weizheng [1 ]
Li, Zhongqing [2 ]
Du, Dingxiang [2 ]
Zhou, Zexin [2 ]
机构
[1] Key Laboratory of Smart Grid (Tianjin University), Ministry of Education, Nankai District, Tianjin 300072, China
[2] China Electric Power Research Institute, Haidian District, Beijing 100192, China
来源
关键词
D O I
10.13335/j.1000-3673.pst.2014.01.039
中图分类号
学科分类号
摘要
引用
收藏
页码:248 / 254
相关论文
共 50 条
  • [1] The association of a transformer differential protection mal-operation
    Shi, Jian-Zeng
    Liu, Jian-Min
    Liu, Chang-Li
    Gao, Yun-Fei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (07): : 132 - 135
  • [2] Analysis of mal-operation of transformer's differential protection in a 110 kV substation
    Pan, Shu-Yan
    Huang, Biao
    Chen, Yong-Hua
    Li, Yong-Guo
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2005, 29 (19): : 87 - 89
  • [3] Research on a Mal-operation Case of Differential Protection in UHV Transformer
    Zheng, Tao
    Chen, Peilu
    Lu, Ting
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [4] Countermeasures on preventing backup protection mal-operation during load flow transferring
    Lin, Xiangning
    Yu, Kun
    Tong, Ning
    Li, Zhengtian
    Khalid, Muhammad Shoaib
    Huang, Jingguang
    Li, Zhongqing
    Zhang, Rui
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 79 : 27 - 33
  • [5] Mal-operation analysis on magnetic inrush current of power transformer
    Wang, Li-Da
    Duan, Zhou-Chao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (10): : 138 - 140
  • [6] Analysis of a sort of unusual mal-operation of transformer differential protection due to removal of external fault
    Lin, Xiangning
    Weng, Hanli
    Liu, Pei
    Wang, Bin
    Bo, Zhiqian
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) : 1374 - 1379
  • [7] A novel explanation to the mal-operation of differential protection during the loaded transformer energization
    Electrical Engineering Department, Huazhong University of Science and Technology, Wuhan 430074, China
    Zhongguo Dianji Gongcheng Xuebao, 2006, 20 (27-32):
  • [8] Analysis on mal-operation of differential protection caused by sympathetic inrush
    State Key Lab. of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    不详
    不详
    Dianli Xitong Zidonghue, 2007, 22 (36-40):
  • [9] New algorithm based on the mathematical morphology for avoiding mal-operation of transformer differential protection
    Zheng, Tao
    Liu, Wan-Shun
    Liu, Jian-Fei
    Xiao, Shi-Wu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2005, 25 (20): : 6 - 11
  • [10] A New Algorithm Based on the Morphological Gradient for Avoiding Mal-operation of Transformer Differential Protection
    Gu, J.
    Zheng, T.
    Huang, S. F.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,