Design method of convex master gratings for replicating flat-field concave gratings

被引:0
|
作者
Zhou, Qian [1 ]
Li, Li-Feng [1 ]
机构
[1] State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, China
关键词
Diffraction efficiency - Refraction - Optical design - Substrates - Diffraction gratings - Image quality - Spectrometers - Spectroscopy;
D O I
10.3964/j.issn.1000-0593(2009)08-2281-04
中图分类号
学科分类号
摘要
Flat-field concave diffraction grating is the key device of a portable grating spectrometer with the advantage of integrating dispersion, focusing and flat-field in a single device. It directly determines the quality of a spectrometer. The most important two performances determining the quality of the spectrometer are spectral image quality and diffraction efficiency. The diffraction efficiency of a grating depends mainly on its groove shape. But it has long been a problem to get a uniform predetermined groove shape across the whole concave grating area, because the incident angle of the ion beam is restricted by the curvature of the concave substrate, and this severely limits the diffraction efficiency and restricts the application of concave gratings. the authors present a two-step method for designing convex gratings, which are made holographically with two exposure point sources placed behind a plano-convex transparent glass substrate, to solve this problem. The convex gratings are intended to be used as the master gratings for making aberration-corrected flat-field concave gratings. To achieve high spectral image quality for the replicated concave gratings, the refraction effect at the planar back surface and the extra optical path lengths through the substrate thickness experienced by the two divergent recording beams are considered during optimization. This two-step method combines the optical-path-length function method and the ZEMAX software to complete the optimization with a high success rate and high efficiency. In the first step, the optical-path-length function method is used without considering the refraction effect to get an approximate optimization result. In the second step, the approximate result of the first step is used as the initial value for ZEMAX to complete the optimization including the refraction effect. An example of design problem was considered. The simulation results of ZEMAX proved that the spectral image quality of a replicated concave grating is comparable with that of a directly recorded concave grating.
引用
收藏
页码:2281 / 2285
相关论文
共 50 条
  • [21] Errors Analysis of Flat-Field Gratings Fabricated by EBL-NFH and Errors Compensation
    Lin Dakui
    Chen Huoyao
    Liu Zhengkun
    Liu Ying
    ACTA OPTICA SINICA, 2018, 38 (05)
  • [22] DESIGN AND PERFORMANCE OF HOLOGRAPHIC CONCAVE GRATINGS
    NAMIOKA, T
    SEYA, M
    NODA, H
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1976, 15 (07) : 1181 - 1197
  • [23] Design of aberration-corrected flat-field holographic concave grating by parameter optimization
    Huang, Yuanshen
    Zhu, Dongyue
    Li, Baicheng
    Zhang, Dawei
    Ni, Zhengji
    Zhuang, Songlin
    OPTIK, 2012, 123 (19): : 1797 - 1800
  • [24] Design of planar waveguide concave diffraction gratings
    School of Optoelectronics Information and Communication Engineering, Beijing Information Science and Technology University, Beijing 100192, China
    不详
    Guangxue Jingmi Gongcheng, 2008, 6 (993-998):
  • [25] Generalized method for designing concave gratings for microspectrometer
    Wang, DY
    Yan, YB
    Jin, GF
    He, QS
    CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL SYSTEMS ENGINEERING, 2000, 4093 : 490 - 496
  • [26] Effect of curve groove on the spectral resolution for soft X-ray holographic flat-field gratings
    Chen Huo-Yao
    Liu Zheng-Kun
    Wang Qing-Bo
    Yi Tao
    Yang Guo-Hong
    Hong Yi-Lin
    Fu Shao-Jun
    ACTA PHYSICA SINICA, 2014, 63 (23)
  • [27] A portable flat-field concave grating spectrometer with high resolution
    Zhou Qian
    Pang Jinchao
    Ni Kai
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS VI, 2014, 9271
  • [28] Experimental evaluation of flat-field spectrograph with a holographic concave grating
    Shen, Weimin
    Bao, Ren
    Guangxue Jishu/Optical Technique, 1998, (01): : 20 - 22
  • [29] Design of a flat-field miniature spectrometer
    Wang, DY
    Jin, GF
    Yan, YB
    Wu, MX
    INSTRUMENTS FOR OPTICS AND OPTOELECTRONIC INSPECTION AND CONTROL, 2000, 4223 : 27 - 30
  • [30] Design of holographic gratings recorded with aspheric wave-front recording optics for soft X-ray flat-field spectrographs
    Koike, M
    Yamazaki, T
    Harada, Y