Study on treatment performance of rural wastewater using the improved constructed rapid infiltration system-The influence of hydraulic loading cycle

被引:0
|
作者
Sun, Qi-Ya [1 ]
Wang, Lin [1 ]
Li, Yong-Mei [1 ]
机构
[1] College of Environmental Science and Engineering, Tongji University, Shanghai,200092, China
关键词
Ammonia - Denitrification - Effluent treatment - Municipal solid waste - Nitrification - Nitrogen removal - Wastewater treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Based on the conventional constructed rapid infiltration (CRI) system, the improved CRI system with non-saturated and saturated layers was constructed. The effects of three hydraulic loading cycles (3, 6 and 12h) on the treatment performance of rural domestic wastewater were investigated when corn cob was added as solid carbon source in the saturated layer, and the microbial mechanism was further elucidated. The results showed that the optimal hydraulic loading cycle of the improved CRI system was 6h. Under the optimal hydraulic loading cycle, the average effluent concentrations of chemical oxygen demand (COD), ammonia nitrogen, total nitrogen and total phosphorus were 5.40, 0.91, 5.59 and 0.47mg/L, respectively. The effluent water quality index meets the Discharge standard of pollutants for municipal wastewater treatment plant (GB 18918-2002) level A standard. The results of microbiological analyses implied that the removal of COD mainly occurred in the non-saturated layer of the system, and the Proteobacteria and Actinobacteria were the main functional microorganisms involved in the metabolism of organics. Nitrification also occurred in the non-saturated layer, and Nitrospirae was the main nitrifier. Functional microorganism Chloroflexi in the saturated layer could degrade corn cobs and provide sufficient carbon source for denitrification process, and carry high abundance of key functional genes for denitrification at the same time, facilitating the denitrification process in the saturated layer. This study can not only provide a basis for the resource utilization of agricultural wastes, but also provide technical support for the improved CRI system to strengthen the treatment of rural domestic wastewater. © 2024 Chinese Society for Environmental Sciences. All rights reserved.
引用
收藏
页码:2431 / 2439
相关论文
共 50 条
  • [31] Performance of an On-Site Wastewater Treatment System Using Reactive Filter Media and a Sequencing Batch Constructed Wetland
    Hamisi, Rajabu
    Renman, Agnieszka
    Renman, Gunno
    SUSTAINABILITY, 2019, 11 (11)
  • [32] Influence of inoculation ratio on the performance and microbial community of bacterial-algal symbiotic system for rural wastewater treatment
    Liyun, Cai
    WATER ENVIRONMENT RESEARCH, 2023, 95 (02)
  • [33] Performance of a small on-site wastewater treatment system using absorbent biofilter for Korean rural community
    Kwun, Soon Kuk
    Yoon, Chun G.
    Kimn, Batu
    1701, Marcel Dekker Inc, New York (35):
  • [34] Performance of a small on-site wastewater treatment system using absorbent biofilter for Korean rural community
    Kwun, SK
    Yoon, CG
    Kimn, B
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2000, 35 (09): : 1701 - 1717
  • [35] Influence of hydraulic retention time and plant species on performance of mesocosm subsurface constructed wetlands during municipal wastewater treatment in super-arid areas
    Vera, Ismael
    Verdejo, Nathaly
    Chavez, Wladimir
    Jorquera, Camila
    Olave, Jorge
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2016, 51 (02): : 105 - 113
  • [36] Performance of olive mill wastewater treatment using hybrid system combining sand filtration and vertical flow constructed wetlands
    Achak, Mounia
    Boumya, Wafaa
    Elamraoui, Sabah
    Asdiou, Nouhaila
    Taoufik, Nawal
    Barka, Noureddine
    Aboulkas, Adil
    Lamy, Edvina
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 53
  • [37] Performance of the first stage of the French system of vertical flow constructed wetlands with only two units in parallel: influence of pulse time and instantaneous hydraulic loading rate
    Garcia Zumalacarregui, Jorge A.
    von Sperling, Marcos
    WATER SCIENCE AND TECHNOLOGY, 2018, 78 (04) : 848 - 859
  • [38] Performance assessment of horizontal and vertical surface flow constructed wetland system in wastewater treatment using multivariate principal component analysis
    Verma, Rashmi
    Suthar, Surindra
    ECOLOGICAL ENGINEERING, 2018, 116 : 121 - 126
  • [39] Insight into using multi-omics analysis to elucidate nitrogen removal mechanisms in a novel improved constructed rapid infiltration system: Functional gene and metabolite signatures
    Sun, Qiya
    Zhang, Zhipeng
    Ping, Qian
    Wang, Lin
    Li, Yongmei
    WATER RESEARCH, 2024, 267
  • [40] Influence of organic loading rate on purified terephthalic acid wastewater treatment in a temperature staged anaerobic treatment (TSAT) system: Performance and metagenomic characteristics
    Ma, Kai-li
    Li, Xiang-kun
    Bao, Lin-lin
    CHEMOSPHERE, 2019, 220 : 1091 - 1099