Seismic performance of pre-stressed high-strength concrete pile reinforced with steel fibre

被引:3
|
作者
Wang, T.C. [1 ,2 ]
Wang, W.J. [1 ]
Zhao, H.L. [1 ,2 ]
Yang, Z.J. [1 ]
机构
[1] School of Civil Engineering, Tianjin University, Tianjin,300072, China
[2] Key Laboratory of Coast Civil Structure (Tianjin University), Ministry of Education, Tianjin,300072, China
关键词
Energy dissipation;
D O I
10.1179/1432891715Z.0000000001638
中图分类号
学科分类号
摘要
In this paper, steel fibre is applied to reinforce pre-stressed high-strength concrete pile in order to improve its seismic performance. The pre-stressed high-strength concrete piles reinforced with shearing J-end steel fibre and steel-wire J-end steel fibre, respectively, are selected here for low-reversed cyclic loading test to analyse the ductility, rigidity degeneration and energy dissipating capacity of such components. The results show that the ductility of pre-stressed high-strength concrete pile reinforced with steel fibre is not improved significantly while the horizontal bearing capacity is enhanced. © W. S. Maney & Son Ltd 2015.
引用
收藏
页码:125 / 131
相关论文
共 50 条
  • [31] Mechanical behaviour of thermally damaged high-strength steel fibre reinforced concrete
    G. M. Giaccio
    R. L. Zerbino
    Materials and Structures, 2005, 38 (3) : 335 - 342
  • [32] Seismic Performance of Steel tube-reinforced Steel Fiber high-strength Concrete Columns with ultra-high Strength Steel Bars
    Zhang, Jianwei
    Liu, Xiao
    Kan, Wenliang
    Zhang, Man
    Liu, Juan
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (08) : 2088 - 2118
  • [33] Effect of Vanadium on Delayed Fracture Resistance of High Strength Pre-Stressed Concrete Steel Bar
    Xiao, Guizhi
    Wang, Qingjuan
    Pang, Yuhua
    ADVANCES IN CHEMICAL, MATERIAL AND METALLURGICAL ENGINEERING, PTS 1-5, 2013, 634-638 : 1708 - 1711
  • [34] Experimental Research on Seismic Performance of High-Strength Concrete Short Column Reinforced with High-Strength Rebar
    Yan Shi
    Sun Shuang-xi
    Chen Xin
    Wu Yu-mo
    2014 INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING, ENERGY AND ENVIRONMENT (CEEE2014), 2015, 5 : 54 - 59
  • [35] A STUDY ABOUT THE INFLUENCE OF FIBRE TYPE AND CONTENT ON PROPERTIES OF STEEL BAR REINFORCED HIGH-STRENGTH STEEL FIBRE REINFORCED CONCRETE
    Mueller, T.
    Kieslich, H.
    Kaeseberg, S.
    Holschemacher, K.
    FIBRE CONCRETE 2009: TECHNOLOGY, DESIGN, APPLICATION, 2009, : 197 - 204
  • [36] Fatigue of high-strength fibre-reinforced concrete
    Badr, Atef
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2007, 14 (05) : 352 - 357
  • [37] Field study of residual forces developed in pre-stressed high-strength concrete (PHC) pipe piles
    Kou, Hai-lei
    Chu, Jian
    Guo, Wei
    Zhang, Ming-yi
    CANADIAN GEOTECHNICAL JOURNAL, 2016, 53 (04) : 696 - 707
  • [38] Pre-Stressed Rope Reinforced Anti-Sliding Pile
    XU Jun 1
    2. Graduate University of Chinese Academy of Sciences
    Wuhan University Journal of Natural Sciences, 2006, (04) : 887 - 891
  • [39] STUDY ON THE FACTORS AFFECTING THE ANTI-SEISMIC PERFORMANCE OF STEEL REINFORCED HIGH-STRENGTH CONCRETE COLUMNS
    Yang, Baosheng
    Song, Shihua
    ADVANCED ENGINEERING MATERIALS II, PTS 1-3, 2012, 535-537 : 1842 - 1846
  • [40] Seismic Performance of Pile-Cap Connections of Prestressed High-Strength Concrete Pile with Different Details
    Guo, Zhaosheng
    He, Wubin
    Bai, Xiaohong
    Chen, Y. Frank
    STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (04) : 546 - 557