The purpose of this study was to evaluate principal component analysis method to power spectral density acquired with autoregressive modeling (AR) of carotid artery Doppler signals. Carotid artery Doppler signals from patient with atherosclerosis and healthy subjects were recorded. Afterwards, power spectral densities of these signals were obtained using AR method. The basic differences between the healthy and patients were obtained with 1st principal component obviously. These results could be extrapolated to situations involving noninvasive measurement where PCA can be extremely time saving. As a result the patient and healthy groups are separated clearly from each other via an arbitrary power function y = ax with perfect accuracy resulting in a precision sensitivity and specificity of 100 percent and the use of PCA of physiological waveform is presented as a powerful method likely to be incorporated in future medical signal processing. © 2006 - IOS Press and the authors. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [41] Modeling and Simulation of Artery Occlusion for Early Detection of Carotid Atherosclerosis
    Wang, Weiduo
    Yang, Dan
    Lu, Yi
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 4948 - 4952
  • [43] Detection of Eye Blinking Using Doppler Sensor With Principal Component Analysis
    Kim, Youngwook
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2015, 14 : 123 - 126
  • [44] SCREENING FOR CAROTID JUNCTION DISEASE BY SPECTRAL ANALYSIS OF DOPPLER SIGNALS
    BASKETT, JJ
    BEASLEY, MG
    MURPHY, GJ
    HYAMS, DE
    GOSLING, RG
    CARDIOVASCULAR RESEARCH, 1977, 11 (02) : 147 - 155
  • [45] Threat Detection In GPR Data Using Autoregressive Modelling
    Sahin, Selim
    Demir, Cagri
    Erer, Isin
    2020 28TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2020,
  • [46] Temporal and Spectral Analysis of Internal Carotid Artery Doppler Signal for Normal and Abnormal Flow Detection
    Krishnamoorthy, P.
    Patil, Ravindra B.
    Ravi, Vidya
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6122 - 6125
  • [47] SELECTION OF THE ORDER OF AUTOREGRESSIVE MODELS FOR SPECTRAL-ANALYSIS OF DOPPLER ULTRASOUND SIGNALS
    SCHLINDWEIN, FS
    EVANS, DH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (01): : 81 - 91
  • [48] DETECTION OF OCCLUSIVE DISEASE OF THE CAROTID-ARTERY WITH CONTINUOUS WAVE DOPPLER SPECTRAL-ANALYSIS
    BROWN, PM
    JOHNSTON, KW
    DOUVILLE, Y
    SURGERY GYNECOLOGY & OBSTETRICS, 1982, 155 (02): : 183 - 186
  • [49] BAEPs averaging analysis using autoregressive modelling
    Vannier E.
    Naït-Ali A.
    Journal of Clinical Monitoring and Computing, 2004, 18 (3) : 147 - 155
  • [50] Analysis of application possibilities of autoregressive modelling to Doppler blood flow signal spectral analysis
    Kaluzynski, K.
    Medical and Biological Engineering and Computing, 1987, 25 (04): : 373 - 376