Ring artifact correction for X-ray computed tomography

被引:1
|
作者
Ma, Jiming [1 ,2 ]
Song, Yan [2 ]
Wang, Qunshu [2 ]
Song, Guzhou [2 ]
Zhang, Jianqi [1 ]
Xia, Jingtao [2 ]
Han, Changcai [2 ]
Duan, Baojun [2 ]
Du, Jiye [2 ]
Zhou, Ming [2 ]
机构
[1] School of Physics and Optoelectronic Engineering, Xidian University, Xi'an, China
[2] State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China
关键词
Computerized tomography;
D O I
10.11884/HPLPB201426.124001
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Prior-Guided Metal Artifact Reduction for Iterative X-Ray Computed Tomography
    Chang, Zhiqian
    Ye, Dong Hye
    Srivastava, Somesh
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1532 - 1542
  • [22] Metal artifact reduction in x-ray computed tomography: inpainting versus missing value
    Heil, Ulrich
    Gross, Daniel
    Schulze, Ralf
    Schwanecke, Ulrich
    Schoemer, Elmar
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2675 - 2677
  • [23] Metal Artifact Reduction in X-Ray Computed Tomography Based On Local Anatomical Similarity
    Dong, X.
    Yang, X.
    Rosenfield, J.
    Elder, E.
    Dhabaan, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3326 - 3326
  • [24] A method for zinger artifact reduction in high-energy x-ray computed tomography
    Mertens, J. C. E.
    Williams, J. J.
    Chawla, Nikhilesh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 800 : 82 - 92
  • [25] High-kVp Assisted Metal Artifact Reduction for X-Ray Computed Tomography
    Xi, Yan
    Jin, Yannan
    De Man, Bruno
    Wang, Ge
    IEEE ACCESS, 2016, 4 : 4769 - 4776
  • [26] Sparsity Constrained Sinogram Inpainting for Metal Artifact Reduction in X-ray Computed Tomography
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3694 - 3699
  • [27] Theoretical Beam Hardening Correction for Industrial X-ray Computed Tomography
    Ahmed, Osama M. H.
    Song, YuShou
    Xie, Zhaoyang
    JOURNAL OF ENGINEERING AND TECHNOLOGICAL SCIENCES, 2019, 51 (06): : 869 - 880
  • [28] X-ray scatter correction method for dedicated breast computed tomography
    Sechopoulos, Ioannis
    MEDICAL PHYSICS, 2012, 39 (05) : 2896 - 2903
  • [29] A reference workpiece for voxel size correction in X-ray computed tomography
    Lifton, Joseph J.
    Cross, Kevin J.
    Malcolm, Andrew A.
    McBride, John W.
    INTERNATIONAL CONFERENCE ON OPTICS IN PRECISION ENGINEERING AND NANOTECHNOLOGY (ICOPEN2013), 2013, 8769
  • [30] X-ray fluorescence computed tomography with absorption correction for biomedical samples
    Yang, Qun
    Deng, Biao
    Du, Guohao
    Xie, Honglan
    Zhou, Guangzhao
    Xiao, Tiqiao
    Xu, Hongjie
    X-RAY SPECTROMETRY, 2014, 43 (05) : 278 - 285