Nonlinear analysis on 3-channel arterial pulse for fast heart rate algorithm

被引:0
|
作者
Medical Research Center, Seoul National University, Yongun-dong, Chono-gu, Seoul, Korea, Republic of [1 ]
不详 [2 ]
机构
来源
WSEAS Trans. Syst. | 2006年 / 8卷 / 1889-1894期
关键词
Algorithms - Computational methods - Spectrum analysis - Waveform analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Nonlinear analysis on arterial pulse is very useful method for finding fast heart rate algorithm and multi-channell waveforms engages faster and more accurate heart rate algorithm. In this paper, we found the relation between the arterial pulse waveform and heart rate through nonlinear analysis with return map. With our own arterial pulse inspector, we collected 3-channel arterial pulse waveforms as continuous signal inputs and analyzed the waveforms using nonlinear characteristic analysis for finding the fast heart rate algorithm. Many types of arterial pulse waveform enables many different analysis results and finally we showed that nonlinear characteristics in the 3-channel arterial pulse waveform can reflect the characteristics of the heart rate sufficiently. As the results of analyses, the nonlinear analysis algorithm showed accurate peak detection and it can easily be used on the heart rate analyzer as a fast heart rate algorithm.
引用
收藏
相关论文
共 50 条
  • [31] Nonlinear analysis of heart rate dynamics in hyperthyroidism
    Chen, Jin-Long
    Tseng, Yin-Jiun
    Chiu, Hung-Wen
    Hsiao, Tzu-Chien
    Chu, Woei-Chyn
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (04) : 427 - 437
  • [32] Nonlinear analysis of heart rate and respiratory dynamics
    Hoyer, D.
    Schmidt, K.
    Bauer, R.
    Zwiener, U.
    Köhler, M.
    Lüthke, B.
    Eiselt, M.
    IEEE Engineering in Medicine and Biology Magazine, 16 (01): : 31 - 39
  • [33] Nonlinear analysis of heart rate and respiratory dynamics
    Hoyer, D
    Schmidt, K
    Bauer, R
    Zwiener, U
    Kohler, M
    Luthke, B
    Eiselt, M
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (01): : 31 - 39
  • [34] Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm
    Felbinger, TW
    Reuter, DA
    Eltzschig, HK
    Moerstedt, K
    Goedje, O
    Goetz, AE
    JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (04) : 296 - 301
  • [35] A Stochastic Nonlinear Autoregressive Algorithm Reflects Nonlinear Dynamics of Heart-Rate Fluctuations
    Antonis A. Armoundas
    Kihwan Ju
    Nikhil Iyengar
    Jorgen K. Kanters
    Philip J. Saul
    Richard J. Cohen
    Ki H. Chon
    Annals of Biomedical Engineering, 2002, 30 : 192 - 201
  • [36] A stochastic nonlinear autoregressive algorithm reflects nonlinear dynamics of heart-rate fluctuations
    Armoundas, AA
    Ju, KW
    Iyengar, N
    Kanters, JK
    Saul, PJ
    Cohen, RJ
    Chon, KH
    ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (02) : 192 - 201
  • [37] The effect of heart rate and pulse pressure on mean arterial pressure: the combined formula for calculation of mean arterial pressure
    Kaypakli, Onur
    Ozgeyik, Mehmet
    BLOOD PRESSURE MONITORING, 2021, 26 (05) : 373 - 379
  • [38] Arterial stiffness increases with an increase in paced heart rate as measured by systemic arterial compliance and pulse wave velocity
    Gatzka, C
    Dart, A
    JOURNAL OF HYPERTENSION, 2002, 20 : S255 - S255
  • [39] Heart Rate Dependence of Aortic Pulse Wave Velocity at Different Arterial Pressures in Rats
    Tan, Isabella
    Butlin, Mark
    Liu, Ying Yi
    Keith Ng
    Avolio, Alberto P.
    HYPERTENSION, 2012, 60 (02) : 528 - 533
  • [40] THE EFFECT OF HEART RATE ON AMBULATORY PULSE PRESSURE IS SENSITIVE TO THE VARIATION OF ARTERIAL STIFFNESS WITH PRESSURE
    Gavish, B.
    Bursztyn, M.
    JOURNAL OF HYPERTENSION, 2015, 33 : E37 - E38