摘要
Miniaturized optical emission spectrometric (OES) devices based on various microplasma excitation sources provide a reliable tool for in-situ elemental analysis. The key to improving analytical performance is enhancing the excitation capability of the microplasma source in these devices. Here, dielectric barrier discharge (DBD) and point discharge (PD) technologies are combined to construct an enhanced dual-stage excitation source (called DBD-PD), which improves the overall excitation efficiency and OES signal sensitivity. Specifically, DBD serves as a pre-excitation source in a narrow discharge chamber, significantly reducing energy consumption during breakdown discharge gas, while improving the excitation capability of subsequent PD microplasma. The microplasma parameter characteristics were calculated, and the microplasma state during the excitation process was imaged using a fast-gated intensified charge-coupled device (ICCD) camera, revealing the enhancement mechanism of the DBD-PD excitation source. Compared to other microplasma excitation sources such as DBD, PD and PD-DBD, DBD-PD increased Se and As signal intensity by up to 16.0 and 11.6 times, respectively. Under the optimal conditions, the detection limits of Se and As reached 0.8 and 0.2 μg L−1, respectively, and the relative standard deviations (RSDs) were less than 5%. The analysis of certified reference materials (GBW07601a and GBW10023) and actual water samples verified the reliability and practicability of the proposed method. This analysis strategy not only offers significant leap in field performance of miniaturized OES devices but also holds extensive potential for broader applications in elemental analysis. © 2025 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [21] Dual-stage chemical looping of microalgae for methanol production with negative-carbon emission
    Nurdiawati, Anissa
    Zaini, Ilman Nuran
    Aziz, Muhammad
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 842 - 847
  • [22] ANALYTICAL POSSIBILITIES OF A SOURCE FOR THE ELECTRONIC EXCITATION OF ATOMS FOR ATOMIC EMISSION ANALYSIS
    KRYUCHKOV, VM
    KRASILSHCHIK, VZ
    CHUPAKHIN, MS
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (12): : 1631 - 1635
  • [23] Dual-Stage Multiple Parameters Estimation for Low-Margin Elastic Optical Networks
    Wan, Zhiquan
    Yu, Zhenming
    Shu, Liang
    Hu, Shaohua
    Zhang, Jing
    Xu, Kun
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2020, 32 (02) : 109 - 112
  • [24] Microdischarge in Flame as a Source-in-Source for Boosted Excitation of Optical Emission of Chromium
    Li, Peixia
    Hu, Jing
    Zhang, Meng
    He, Lin
    Li, Kai
    Hou, Xiandeng
    Jiang, Xiaoming
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (21) : 7683 - 7691
  • [25] Hardware optimization of dual-stage carrier-phase recovery for coherent optical receivers
    Martins, Celestino S.
    Guiomar, Fernando P.
    Pinto, Armando N.
    [J]. OSA CONTINUUM, 2021, 4 (12): : 3157 - 3175
  • [26] An inverse-kinematic approach to dual-stage servo control for an optical pointing system
    Miller, Eric D.
    [J]. FREE-SPACE LASER COMMUNICATION AND ATMOSPHERIC PROPAGATION XXX, 2018, 10524
  • [27] Low-hump sensitivity function design for dual-stage HDD systems with different microactuators
    Du, C
    Guo, G
    Wu, D
    [J]. IEE PROCEEDINGS-CONTROL THEORY AND APPLICATIONS, 2005, 152 (06): : 655 - 661
  • [28] Advance in the excitation source in glow discharge optical emission spectrometry
    Wagatsuma, K
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2002, 88 (04): : 169 - 179
  • [29] Speed of Sound Estimation for Dual-Stage Virtual Source Ultrasound Beamforming Using Point Scatterers
    Ma, Manyou
    Rohling, Robert
    Lampe, Lutz
    [J]. MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139
  • [30] An excitation emission fluorescence lifetime spectrometer using a frequency doubled supercontinuum laser source
    Melnikau, Dzmitry
    Elcoroaristizabal, Saioa
    Ryder, Alan G.
    [J]. METHODS AND APPLICATIONS IN FLUORESCENCE, 2018, 6 (04):