Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors

被引:1
|
作者
Yildiz, D. E. [1 ]
Tasaltin, N. [2 ,3 ,4 ]
Karakus, S. [5 ,6 ]
Gursu, G. [2 ,3 ]
Baytemir, G. [2 ,7 ]
Kose, D. A. [8 ]
机构
[1] Hitit Univ, Dept Phys, Corum, Turkiye
[2] Maltepe Univ, Environm & Energy Technol Res Ctr, Istanbul, Turkiye
[3] Maltepe Univ, Dept Basic Sci, Istanbul, Turkiye
[4] Maltepe Univ, Dept Renewable Energy Tech & Management, Istanbul, Turkiye
[5] Istanbul Univ Cerrahpasa, Fac Engn, Dept Chem, Analyt Chem Sect 34320, Istanbul, Turkiye
[6] Hlth Biotechnol Joint Res & Applicat Ctr Excellenc, TR-34220 Esenler, Istanbul, Turkiye
[7] Maltepe Univ, Dept Elect & Elect Engn, Istanbul, Turkiye
[8] Hitit Univ, Dept Chem, Corum, Turkiye
关键词
nanocomposite; sensors; dopamine; polyaniline; Ni(Phala)(2); Zn(Phala)(2); Co(Phala)(2); GRAPHENE OXIDE; NANOCOMPOSITES; ELECTROCATALYST; CARBON;
D O I
10.1149/1945-7111/ad7c80
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This study presents a comparative analysis of non-enzymatic electrochemical voltammetric sensors, utilizing phenylalanine amino acid metal complexes (M: Ni, Zn, and Co) Polyaniline (PANI) nanocomposites (NCs). The PANI: Zn(Phala)2 NCs-based sensor detected dopamine (DA) with a sensitivity of 101.18 mu A mu M-1 cm(-2). The limit of detection (LOD) for the PANI: Zn(Phala)(2) NCs-based sensor was calculated as 0.391 mu M. This exceptional sensitivity makes the PANI: Zn(Phala)(2) NCs-based sensor highly promising for potential integration into biomedical test kits. To gain deeper insights into the structural properties of the PANI NCs, scanning electron microscopy (SEM), artificial-intelligence-based SEM, and Fourier transform infrared spectroscopy (FTIR) were employed for characterization. FTIR characterization provided insights into the functional groups of the NCs. The results of this comparative investigation a significant advancement in the field of PANI-based electrochemical sensors designed for DA sensing. The PANI: Zn(Phala)(2) NCs-based sensor show great promise for a range of advanced sensing applications. The Z value of the PANI: Zn(Phala)(2) NCs-based sensor is the lowest among the tested materials, indicating that the conductivity of the PANI: Zn(Phala)(2) layer is higher than that of other active layers. Consequently, the PANI: Zn(Phala)(2) NCs-based sensor achieved higher sensitivity in DA detection. (c) 2024 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited. All rights, including for text and data mining, AI training, and similar technologies, are reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Nanomaterials based non-enzymatic electrochemical and optical sensors for the detection of carbendazim: A review
    Suresh, Indhu
    Selvaraj, Stalin
    Nesakumar, Noel
    Rayappan, John Bosco Balaguru
    Kulandaiswamy, Arockia Jayalatha
    TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 31
  • [42] Non-Enzymatic Glucose Sensors Composed of Polyaniline Nanofibers with High Electrochemical Performance
    Sobahi, Nebras
    Alam, Md. Mottahir
    Imran, Mohd
    Khan, Mohammad Ehtisham
    Mohammad, Akbar
    Yoon, Taeho
    Mehedi, Ibrahim M.
    Hussain, Mohammad A.
    Abdulaal, Mohammed J.
    Jiman, Ahmad A.
    MOLECULES, 2024, 29 (11):
  • [43] Review of oxygen-vacancies nanomaterials for non-enzymatic electrochemical sensors application
    Gurusamy, Lakshmanan
    Karuppasamy, Lakshmanan
    Anandan, Sambandam
    Barton, Scott C.
    Chuang, Ya-Hui
    Liu, Cheng-Hua
    Wu, Jerry J.
    COORDINATION CHEMISTRY REVIEWS, 2023, 484
  • [44] Non-enzymatic electrochemical sensors based on nanomaterials for detection of organophosphorus pesticide residues
    Zhou, Chuanqin
    Feng, Jinxia
    Tian, Yaling
    Wu, Yiyong
    He, Quanguo
    Li, Guangli
    Liu, Jun
    ENVIRONMENTAL SCIENCE-ADVANCES, 2023, 2 (07): : 933 - 956
  • [45] Advances in nanostructured material-based non-enzymatic electrochemical glucose sensors
    Jiang, Danfeng
    Liu, Tao
    Chu, Zhenyu
    Wang, Yi
    ANALYTICAL METHODS, 2023, 15 (46) : 6344 - 6361
  • [46] Electrochemical Characterization of Modified Glassy Carbon Electrodes for Non-Enzymatic Glucose Sensors
    Mazurkow, Julia Maria
    Kusior, Anna
    Radecka, Marta
    SENSORS, 2021, 21 (23)
  • [47] Non-enzymatic electrochemical immunoassay using noble metal nanoparticles: a review
    Tang, Juan
    Tang, Dianping
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2077 - 2089
  • [48] NON-ENZYMATIC, TETRAHYDROBIOPTERIN-MEDIATED HYDROXYLATION OF PHENYLALANINE
    BLAIR, JA
    PEARSON, AJ
    JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1975, (03): : 245 - 249
  • [49] Recent advances in non-enzymatic electrochemical glucose sensors based on non-precious transition metal materials: opportunities and challenges
    Niu, Xiangheng
    Li, Xin
    Pan, Jianming
    He, Yanfang
    Qiu, Fengxian
    Yan, Yongsheng
    RSC ADVANCES, 2016, 6 (88) : 84893 - 84905
  • [50] Non-enzymatic electrochemical immunoassay using noble metal nanoparticles: a review
    Juan Tang
    Dianping Tang
    Microchimica Acta, 2015, 182 : 2077 - 2089