Vibration measurement in full-scale field test of 6 story wood framework wall system under ambient vibration

被引:0
|
作者
Hamamoto T. [1 ,3 ]
Kunimatsu S. [2 ]
Hirao Y. [4 ]
Kobayashi M. [1 ,3 ]
机构
[1] Tokyo City Univ., Japan
[2] AlST, Japan
[3] Tokyo City Univ, Japan
[4] Kobayashi Institute of Physical Research, Japan
关键词
Ambient vibration; Environmental vibration; Full-scale field test; Vibration characteristics; Vibration measurement; Wood framework wall system;
D O I
10.3130/aijt.25.215
中图分类号
学科分类号
摘要
Vibration measurement has been performed in a full-scale field test of 6 story wood framework wall system. 6 microtremor sensors and 20 MEMS acceleration sensors were installed to understand the dynamic behaviors of the target building considering soil-structure interaction, and to estimate modal properties of the superstructure in translational and torsional vibrations. It is concluded that the overall behaviors of the target building are governed by rocking motion of the foundation subsystem rather than dynamic characteristics of the superstructure subsystem. © 2019 Architectural Institute of Japan. All Rights Reserved.
引用
收藏
页码:215 / 218
页数:3
相关论文
共 50 条
  • [1] Vibration measurement in full-scale field test of 6 story wood framework wall system under external excitation
    Kunimatsu S.
    Hirao Y.
    Hamamoto T.
    Kobayashi M.
    AIJ Journal of Technology and Design, 2019, 25 (59) : 219 - 222
  • [2] Vibration measurement in full-scale field test of 6 story wood framework wall system under real seismic motions
    Hamamoto T.
    Kunimatsu S.
    Kashima T.
    Kobayashi M.
    AIJ Journal of Technology and Design, 2019, 25 (61) : 1061 - 1066
  • [3] Vibration measurement in fullscale field test of 6 story wood framework wall system under internal excitation
    Hamamoto T.
    Kunimatsu S.
    Hirao Y.
    Kobayashi M.
    AIJ Journal of Technology and Design, 2019, 25 (61): : 1149 - 1154
  • [4] Forced vibration of full-scale wall backfill system - Closure
    Elgamal, AW
    Alampalli, S
    Van Laak, P
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1998, 124 (04) : 372 - 373
  • [5] Forced vibration of full-scale wall-backfill system
    Elgamal, AW
    Alampalli, S
    VanLaak, P
    JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1996, 122 (10): : 849 - 858
  • [6] Forced vibration of full-scale wall backfill system - Discussion
    Paruvakat, N
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1998, 124 (04) : 372 - 372
  • [7] An Ambient Vibration Test of an R/C Wall of an 18-Story Wood Building at the UBC Campus
    Kaya, Yavuz
    Ventura, Carlos E.
    Taale, Alireza
    DYNAMICS OF CIVIL STRUCTURES, VOL 2, 2017, : 315 - 320
  • [8] FULL-SCALE TEST OF FRICTION DAMPER FOR CABLE VIBRATION MITIGATION
    Zhou, Hai-Jun
    Sun, Li-Min
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1277 - 1282
  • [9] Full-scale measurement of vibration of Akashi-Kaikyo Bridge
    Katsuchi, H
    Yamada, H
    Hata, K
    Kusuhara, S
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2003, : 1059 - 1065
  • [10] A novel approach for the structural identification and monitoring of a full-scale 17-story building based on ambient vibration measurements
    Nayeri, Reza D.
    Masri, Sami F.
    Ghanem, Roger G.
    Nigbor, Robert L.
    SMART MATERIALS AND STRUCTURES, 2008, 17 (02)