Hybrid system of base-isolated structures with tuned tandem mass damper-inerters considering internal friction

被引:2
|
作者
Li, Xin [1 ]
Wang, Zhihao [2 ]
Pan, Hang [1 ]
Cao, Liyuan [1 ]
Li, Chunxiang [1 ]
机构
[1] Shanghai Univ, Sch Mech & Engn Sci, Dept Civil Engn, Shanghai 200444, Peoples R China
[2] North China Univ Water Resources & Elect Power, Sch Civil Engn & Commun, Zhengzhou 450045, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Hybrid system; Base isolation; Tuned tandem mass damper-inerters; Nonlinearities; Optimal design; SEISMIC RESPONSE; OPTIMUM DESIGN; PERFORMANCE; PUSHOVER; SPECTRUM;
D O I
10.1016/j.jobe.2025.111853
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A hybrid system combining base-isolated structures (BIS) with tuned tandem mass damperinerters (TTMDI), named BIS-TTMDI, is presented. This system can reduce base isolation floor (BIF) deformation while achieving superior seismic performance. However, current investigations of TTMDI are limited to the linear assumption of inerters. In practical terms, the inerter demonstrates nonlinear behavior, characterized by internal friction. Neglecting internal friction can potentially causes design errors and unsatisfactory control performance of TTMDI. In order to address this issue, a combined nonlinearity model that considers Coulomb friction and viscous friction is proposed to characterize the internal friction of the inerter. The nonlinear parameters are identified and validated through mechanical performance tests. This proposed nonlinearity model of the inerter is then incorporated into the hybrid system of BIS with TTMDI, referred to as BIS-NTTMDI. Employing the proposed nonlinearity model of the inerter, an optimization design method for NTTMDI is developed to obtain the optimal tuning parameters. The robustness and stroke of NTTMDI are scrutinized and compared with those of TTMDI. Furthermore, a nonlinear response history analysis is conducted to systematically assess the control performance of BISNTTMDI. The results underscore the importance of considering the internal friction of the inerter in designing BIS-NTTMDI to achieve reliable control performance. Employing the proposed nonlinearity model of the inerter, the influence of internal friction can be appropriately compensated for. Compared with BIS, the optimized BIS-NTTMDI has achieved a maximum reduction of 21.5 % in the displacement of the BIF in this study.
引用
收藏
页数:25
相关论文
共 43 条
  • [31] Performance improvement and demand-oriented optimum design of the tuned negative stiffness inerter damper for base-isolated structures
    Gao, Hui
    Xing, Chenxi
    Wang, Hao
    Li, Jian
    Zhang, Yang
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [32] Seismic Response of Double Concave Friction Pendulum Base-Isolated Structures Considering Vertical Component of Earthquake
    Faramarz, Khoshnudian
    Montazar, Rabiei
    ADVANCES IN STRUCTURAL ENGINEERING, 2010, 13 (01) : 1 - 13
  • [33] Semi-Active Fuzzy Control of Tuned Mass Damper to Reduce Base-Isolated Building Response under Harmonic Excitation
    Djedoui, Nassim
    Ounis, Abdelhafid
    Mahdi, Abdeddaim
    Zahrai, Seyed Mehdi
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2018, 12 (03) : 435 - 448
  • [34] Optimal design of Magnetorheological damper for seismic response reduction of Base-Isolated structures considering Soil-Structure interaction
    Abdeddaim, Mahdi
    Djerouni, Salah
    Ounis, Abdelhafid
    Athamnia, Brahim
    Farsangi, Ehsan Noroozinejad
    STRUCTURES, 2022, 38 : 733 - 752
  • [35] Smart structures through nontraditional design of Tuned Mass Damper Inerter for higher control of base isolated systems
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    MECHANICS RESEARCH COMMUNICATIONS, 2020, 105
  • [36] Enhancing base-isolation structures by optimized configurable friction isolator-tuned inerter damper system
    Wang, Yuxiang
    Ye, Kun
    Hu, Liang
    ENGINEERING STRUCTURES, 2025, 329
  • [37] Mechanism of response reduction in hybrid control system of base-isolated building connected to free-wall with damper
    Hayashi K.
    Mitsuda E.
    Fujita K.
    Tsuji M.
    Takewaki I.
    Journal of Structural and Construction Engineering, 2017, 82 (737): : 1023 - 1033
  • [38] Development of a Hybrid Base Isolation-Tuned Mass Damper Inerter System (BI-TMDI) for Seismic Protection of Steel Structures
    Bian, Jing
    Wang, Lin
    Ke, Ke
    Chen, Yonghui
    Chen, Lingyang
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 685 - 691
  • [39] Stochastic seismic analysis of base-isolated structures with electromagnetic inertial mass dampers considering different soil conditions
    Heng Wang
    Wenai Shen
    Hongping Zhu
    Fan Kong
    Songye Zhu
    Bulletin of Earthquake Engineering, 2023, 21 : 1601 - 1626
  • [40] Stochastic seismic analysis of base-isolated structures with electromagnetic inertial mass dampers considering different soil conditions
    Wang, Heng
    Shen, Wenai
    Zhu, Hongping
    Kong, Fan
    Zhu, Songye
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (03) : 1601 - 1626