Design and Evaluation of a Patellar Tendon-Bearing Brace with Off-Loading Mechanism on Tibia

被引:0
|
作者
Chamani, Vahid [1 ]
Bahramizahed, Mahmood [1 ]
Khosravi, Mobina [2 ]
Biglarian, Akbar [3 ]
Amjad, Gholamreza Ghorbani [4 ]
Mousavi, Seyyed Mohammad Ebrahim [1 ]
Arazpour, Mokhtar [1 ]
机构
[1] Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
[2] Physiotherapy Research Center, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran
[3] Department of Biostatistics and Epidemiology, Social Departments of Health Research Institute, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
[4] Department of Orthopedics, School of Medi-cine, Hamadan University of Medical Sciences, Hamadan, Iran
来源
Journal of Biomedical Physics and Engineering | 2024年 / 14卷 / 04期
关键词
Tendons;
D O I
10.31661/jbpe.v0i0.2403-1738
中图分类号
学科分类号
摘要
The current study aimed to design a patellar-tendon-bearing (PTB) brace capable of measuring and quantifying weight offloading on the tibia. The PTB brace was designed with off-loading mechanism on the tibia with features, including ankle joint, vertical sliding adaptor, vertical sliding piece, and upper connector of load cells to PTB brace. Also, the present study investigated the effect of brace on 20 healthy individuals under 8 different off-loading conditions, based on measuring the vertical distance between the calf shells and foot plate through a sliding adapter at 0.5, 1, 1.5, 2, 2.5, 3, and 3.5 cm. The Pedar device and load cells embedded in PTB brace were used to determine the extent of offloading and assess the reliability and validity of brace. Increasing the vertical distance between the calf shells and the footplate can lead to a greater amount of offloading. Ac-cordingly, off-loading ranged from a minimum of 16.5% at 0 cm position to a maximum of 60.48% at 3.5 cm position of sliding adapter. Percentage values of tibia off-loading in 8 conditions were not significantly different in Padar devices and PTB brace. Therefore, PTB brace load cells, as a valid method, can measure off-loading levels. When fabricat-ing a PTB brace, a monitoring system with load cells is essential to measure the amount of tibial offloading, leading to readjustment if limb slides down inside the brace. Ad-ditionally, a component is needed to correctly position limb in off-loading condition. In the current study, sliding adapter of brace can provide that capability. © Journal of Biomedical Physics and Engineering.
引用
收藏
页码:407 / 414
相关论文
共 50 条
  • [41] Function of the extensor mechanism of the knee after using the 'patellar-loop technique' to reconstruct the patellar tendon when replacing the proximal tibia for tumour
    Pilge, H.
    Holzapfel, B. M.
    Rechl, H.
    Prodinger, P. M.
    Lampe, R.
    Saur, U.
    Eisenhart-Rothe, R.
    Gollwitzer, H.
    BONE & JOINT JOURNAL, 2015, 97B (08): : 1063 - 1069
  • [42] Long-Term Contract Design for Traffic Off-Loading in Heterogeneous Cloud Radio Access Networks
    Wang, Min
    Zhang, Biling
    Yu, Jung-Lang
    Han, Zhu
    2019 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM), 2019,
  • [43] Discovery of a Mosaic-Like Biosynthetic Assembly Line with a Decarboxylative Off-Loading Mechanism through a Combination of Genome Mining and Imaging
    Mohseni, Mahsa Mir
    Hoever, Thomas
    Barra, Lena
    Kaiser, Marcel
    Dorrestein, Pieter C.
    Dickschat, Jeroen S.
    Schaeberle, Till F.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (43) : 13611 - 13614
  • [44] Biomechanical comparison of patellar tendon repairs in a cadaver model - An evaluation of gap formation at the repair site with cyclic loading
    Ravalin, RV
    Mazzocca, AD
    Grady-Benson, JC
    Nissen, CW
    Adams, DJ
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (04): : 469 - 473
  • [45] Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis
    Narita, H
    Yokogushi, K
    Shii, S
    Kakizawa, M
    Nosaka, T
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1997, 21 (03) : 175 - 178
  • [46] Mechanical Evaluation of Bone-Patellar Tendon-Bone Graft Fixation to the Tibia in ACL Reconstruction: Bone Plug Tensioning and Fixation System versus Interference Screw
    Iuchi, Ryo
    Shino, Konsei
    Mae, Tatsuo
    Yamakawa, Satoshi
    Nakata, Ken
    JOURNAL OF KNEE SURGERY, 2024, 37 (13) : 894 - 901
  • [47] Conceptual Design Evaluation of Lightweight Load Bearing Structural Assembly for an Automotive Seat Adjuster Mechanism
    Kajtaz, M.
    Subic, A.
    Takla, M.
    SUSTAINABLE AUTOMOTIVE TECHNOLOGIES 2013, 2014, : 151 - 160
  • [48] The damaging mechanism and performance design of the off-wall tunnel under the dynamic and static combined cycling loading model
    Zhao, Jichang, 1600, Journal of Chemical and Pharmaceutical Research, 3/668 Malviya Nagar, Jaipur, Rajasthan, India (06):
  • [49] Design and evaluation of a slave manipulator with roll-pitch-roll wrist and automatic tool loading mechanism in telerobotic surgery
    Kim, Ki-Young
    Lee, Jung-Ju
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2012, 8 (04): : 421 - 435
  • [50] Strength evaluation of continuous curvilinear variable stiffness panels with circular cutouts under biaxial normal loading and off-design conditions
    Arian Nik, Mahdi
    Fayazbakhsh, Kazem
    Khan, Sadben
    Fawaz, Zouheir
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2022, 29 (25) : 3860 - 3870