Design and Evaluation of a Patellar Tendon-Bearing Brace with Off-Loading Mechanism on Tibia

被引:0
|
作者
Chamani, Vahid [1 ]
Bahramizahed, Mahmood [1 ]
Khosravi, Mobina [2 ]
Biglarian, Akbar [3 ]
Amjad, Gholamreza Ghorbani [4 ]
Mousavi, Seyyed Mohammad Ebrahim [1 ]
Arazpour, Mokhtar [1 ]
机构
[1] Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
[2] Physiotherapy Research Center, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran
[3] Department of Biostatistics and Epidemiology, Social Departments of Health Research Institute, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
[4] Department of Orthopedics, School of Medi-cine, Hamadan University of Medical Sciences, Hamadan, Iran
来源
关键词
Tendons;
D O I
10.31661/jbpe.v0i0.2403-1738
中图分类号
学科分类号
摘要
The current study aimed to design a patellar-tendon-bearing (PTB) brace capable of measuring and quantifying weight offloading on the tibia. The PTB brace was designed with off-loading mechanism on the tibia with features, including ankle joint, vertical sliding adaptor, vertical sliding piece, and upper connector of load cells to PTB brace. Also, the present study investigated the effect of brace on 20 healthy individuals under 8 different off-loading conditions, based on measuring the vertical distance between the calf shells and foot plate through a sliding adapter at 0.5, 1, 1.5, 2, 2.5, 3, and 3.5 cm. The Pedar device and load cells embedded in PTB brace were used to determine the extent of offloading and assess the reliability and validity of brace. Increasing the vertical distance between the calf shells and the footplate can lead to a greater amount of offloading. Ac-cordingly, off-loading ranged from a minimum of 16.5% at 0 cm position to a maximum of 60.48% at 3.5 cm position of sliding adapter. Percentage values of tibia off-loading in 8 conditions were not significantly different in Padar devices and PTB brace. Therefore, PTB brace load cells, as a valid method, can measure off-loading levels. When fabricat-ing a PTB brace, a monitoring system with load cells is essential to measure the amount of tibial offloading, leading to readjustment if limb slides down inside the brace. Ad-ditionally, a component is needed to correctly position limb in off-loading condition. In the current study, sliding adapter of brace can provide that capability. © Journal of Biomedical Physics and Engineering.
引用
收藏
页码:407 / 414
相关论文
共 50 条
  • [1] The effect of the patellar tendon-bearing cast on loading
    Tanaka, H
    Nagata, K
    Goto, T
    Hoshiko, H
    Inoue, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (02): : 228 - 232
  • [2] Efficacy of the patellar tendon-bearing cast
    Sunil, TM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10): : 1511 - 1512
  • [3] The effect of the patellar tendon-bearing cast on loading -: Author's reply
    Goto, T
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (06): : 930 - 930
  • [4] THE PATELLAR TENDON-BEARING BRACE AS TREATMENT FOR NEUROTROPHIC ARTHROPATHY - A DYNAMIC FORCE MONITORING STUDY
    SALTZMAN, CL
    JOHNSON, KA
    GOLDSTEIN, RH
    DONNELLY, RE
    FOOT & ANKLE, 1992, 13 (01): : 14 - 21
  • [5] Treatment of diabetic foot ulcers and charcot neuroarthropathy using the patellar tendon-bearing brace
    Guse, ST
    Alvine, FG
    FOOT & ANKLE INTERNATIONAL, 1997, 18 (10) : 675 - 677
  • [6] Efficacy of the patellar tendon-bearing cast - Reply
    Bhave, A
    Herzenberg, JE
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10): : 1512 - 1512
  • [7] A NEW DIRECTLY MOLDED PATELLAR TENDON-BEARING SOCKET
    BOOT, DA
    YOUNG, NJ
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1985, 9 (02) : 112 - 114
  • [8] EXPERIENCE WITH AN ALL PLASTIC PATELLAR TENDON-BEARING ORTHOSIS
    DEMOPOULOS, JT
    ESCHEN, JE
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1977, 58 (10): : 452 - 456
  • [9] PATELLAR TENDON BEARING BRACE (REPORT OF 16 PATIENTS)
    DAVIS, FJ
    FRY, LR
    LIPPERT, FG
    SIMONS, BC
    REMINGTO.J
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (02): : 421 - 421
  • [10] PATELLAR TENDON BEARING PLASTER CASTS IN FRACTURES OF THE TIBIA
    AHMAD, S
    MAM, MK
    SETHI, TS
    INTERNATIONAL ORTHOPAEDICS, 1989, 13 (04) : 247 - 251