Performance of two-phase ejector in compression/ejection refrigeration cycle

被引:0
|
作者
Wang, Fei [1 ]
Lü, Henglin [1 ]
Feng, Wei [1 ]
Shen, Shengqiang [2 ]
机构
[1] School of Architecture and Engineering, China University of Mining and Technology, Xuzhou 221116, Jiangsu, China
[2] Key Laboratory for Desalination of Liaoning Province, School of Energy and Power Engineering, Dalian University of Technology, Dalian 116024, Liaoning, China
来源
Huagong Xuebao/CIESC Journal | 2012年 / 63卷 / 10期
关键词
Condensation; -; Ejectors; (pumps);
D O I
10.3969/j.issn.0438-1157.2012.10.013
中图分类号
学科分类号
摘要
Taking into account of the phenomena of choking in entrained flow and condensation shock in mixing chamber, a thermodynamic model of two-phase ejector was established by using mass, momentum and energy balances. In the simulation, the mixing area in the mixing chamber is constant. With R141b as refrigerant, the pressure change in the ejector at various mixing pressures was studied, and the effects of mixing pressure on the performance of compression/ejection cycle, the entrainment ratio and exit pressure of ejector were analyzed. The variations of optimum suction chamber pressure drop, the corresponding ejector entrainment ratio, the system optimum performance coefficient and the corresponding performance improvement ratio with condensation temperature and evaporation temperature were presented. The results show that under the operation conditions in this study, no condensation shock occurs in the mixing chamber of two-phase ejector. The constant area model for mixing chamber is more appropriate than constant pressure model. It is important to choose appropriate mixing pressure for optimizing the system performance, and the optimum mixing pressure, at which the ejector has the highest entrainment ratio, is slightly lower than the pressure of entrained flow but far larger than the critical pressure entrained flow.
引用
收藏
页码:3094 / 3100
相关论文
共 50 条
  • [21] Performance analyses of novel two-phase ejector enhanced multi-evaporator refrigeration systems
    Sarkar, Jahar
    APPLIED THERMAL ENGINEERING, 2017, 110 : 1635 - 1642
  • [22] Analysis of application of two-phase injector in ejector refrigeration systems for isobutane
    Smierciew, Kamil
    Butrymowicz, Dariusz
    Kwidzinski, Roman
    Przybylinski, Tomasz
    APPLIED THERMAL ENGINEERING, 2015, 78 : 630 - 639
  • [23] Two-phase radial ejector for transcritical CO2 refrigeration
    Chandran Ramachandran, Jishnu
    Sadasivan, Sreeja
    Arumugam, Senthil Kumar
    Chen, Fei
    PHYSICS OF FLUIDS, 2024, 36 (12)
  • [24] Optimal thermodynamic parameters of two-phase ejector refrigeration system for buses
    Unal, Saban
    Erdinc, Mehmet Tahir
    Kutlu, Cagri
    APPLIED THERMAL ENGINEERING, 2017, 124 : 1354 - 1367
  • [25] A heat transfer model for two-phase flow in an ejector refrigeration system
    Valencia-Canola, Santiago
    Mendez, Federico
    Bustamante, Carlos A.
    APPLIED THERMAL ENGINEERING, 2025, 266
  • [26] Performance evaluation of a modified R290 dual-evaporator refrigeration cycle using two-phase ejector as expansion device
    Gao, Yu
    He, Guogeng
    Cai, Dehua
    Fan, Mingjing
    ENERGY, 2020, 212
  • [27] Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchanger
    Nakagawa, M.
    Marasigan, A. R.
    Matsukawa, T.
    Kurashina, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1604 - 1613
  • [28] The Weak and Strong Oblique Shock Waves Appeared on the Carbon Dioxide Two-phase Flow in the Ejector Refrigeration Cycle
    Kawamura, Y.
    Nakagawa, M.
    IRAGO CONFERENCE 2012, 2013, 433
  • [29] Analysis of a compression/ejection cycle for domestic refrigeration
    Elakdhar, M.
    Nehdi, E.
    Kairouani, L.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2007, 46 (13) : 4639 - 4644
  • [30] Shape optimisation of a two-phase ejector for CO2 refrigeration systems
    Palacz, Michal
    Smolka, Jacek
    Nowak, Andrzej J.
    Banasiak, Krzysztof
    Hafner, Armin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 74 : 212 - 223