共 50 条
Locally Enhanced Flow and Electric Fields Through a Tip Effect for Efficient Flow-Electrode Capacitive Deionization
被引:6
|作者:
Wang, Ziquan
[1
]
Chen, Xiangfeng
[1
]
Zhang, Yuan
[1
]
Ma, Jie
[2
]
Lin, Zhiqun
[3
]
Abdelkader, Amor
[4
,5
]
Titirici, Maria-Magdalena
[6
]
Deng, Libo
[1
]
机构:
[1] Shenzhen Univ, Coll Chem & Environm Engn, Shenzhen 518060, Peoples R China
[2] Tongji Univ, Coll Environm Sci & Engn, Res Ctr Environm Funct Mat, 1239 Siping Rd, Shanghai 200092, Peoples R China
[3] Natl Univ Singapore, Dept Chem & Biomol Engn, Singapore 117585, Singapore
[4] Bournemouth Univ, Fac Sci & Technol, Dept Engn, Talbot Campus, Poole BH125BB, England
[5] Univ Cote Azur, Inst Chim Nice, UMR CNRS 7272, 28 Ave Valrose, F-06108 Nice, France
[6] Imperial Coll, Dept Chem, South Kensington Campus Exhibit Rd, London SW7 2AY, England
基金:
中国国家自然科学基金;
关键词:
Flow-electrode;
Capacitive deionization;
Current collector;
Tip effect;
Desalination;
WATER DESALINATION;
D O I:
10.1007/s40820-024-01531-0
中图分类号:
TB3 [工程材料学];
学科分类号:
0805 ;
080502 ;
摘要:
Steel tip arrays were used as current collectors to replace planar conductors.Optimal flow and electric fields reduced barriers for electron and ion transport.Desalination performance of flow-electrode capacitive deionization is enhanced by the tip-array current collectors. Low-electrode capacitive deionization (FCDI) is an emerging desalination technology with great potential for removal and/or recycling ions from a range of waters. However, it still suffers from inefficient charge transfer and ion transport kinetics due to weak turbulence and low electric intensity in flow electrodes, both restricted by the current collectors. Herein, a new tip-array current collector (designated as T-CC) was developed to replace the conventional planar current collectors, which intensifies both the charge transfer and ion transport significantly. The effects of tip arrays on flow and electric fields were studied by both computational simulations and electrochemical impedance spectroscopy, which revealed the reduction of ion transport barrier, charge transport barrier and internal resistance. With the voltage increased from 1.0 to 1.5 and 2.0 V, the T-CC-based FCDI system (T-FCDI) exhibited average salt removal rates (ASRR) of 0.18, 0.50, and 0.89 mu mol cm-2 min-1, respectively, which are 1.82, 2.65, and 2.48 folds higher than that of the conventional serpentine current collectors, and 1.48, 1.67, and 1.49 folds higher than that of the planar current collectors. Meanwhile, with the solid content in flow electrodes increased from 1 to 5 wt%, the ASRR for T-FCDI increased from 0.29 to 0.50 mu mol cm-2 min-1, which are 1.70 and 1.67 folds higher than that of the planar current collectors. Additionally, a salt removal efficiency of 99.89% was achieved with T-FCDI and the charge efficiency remained above 95% after 24 h of operation, thus showing its superior long-term stability.
引用
收藏
页数:17
相关论文