VSC with a T-connected transformer-based electronic load controller for an isolated asynchronous generator feeding three-phase four-wire loads in a micro hydro system

被引:0
|
作者
Kasal G.K. [1 ]
Singh B. [1 ]
机构
[1] Department of Electrical Engineering, Indian Institute of Technology, Hauz-Khas
关键词
Stand-alone power generation; T-connected transformer; Voltage and frequency control; Voltage source converter;
D O I
10.1504/IJPELEC.2011.042309
中图分类号
学科分类号
摘要
This paper deals with a novel solid state controller (NSSC) for isolated asynchronous generator (IAG) feeding three-phase four-wire loads driven by constant power prime movers, such as uncontrolled micro hydro turbines. AC capacitor banks are used to meet the reactive power requirement of the asynchronous generator. The proposed NSSC is realised using a set of IGBTs (insulated gate bipolar junction transistors) based current controlled voltage source converter (CC-VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The neutral point of the load is created using a T-configuration of the transformers. The IAG system is modelled in MATLAB along with Simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of isolated generating system consisting of NSSC and IAG driven by uncontrolled micro hydro turbine and feeding three-phase four-wire loads. Copyright © 2011 Inderscience Enterprises Ltd.
引用
收藏
页码:496 / 509
页数:13
相关论文
共 28 条
  • [21] Control of Self-Excited Induction Generator-based Micro-Hydro Power Generation System Feeding Single-Phase and Three-Phase Loads
    Chilipi, Rajasekharareddy
    Al Sumaiti, Ameena
    Singh, Bhim
    2020 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2020,
  • [22] Constant DC Capacitor Voltage Control Based Strategy for Active Load Balancer in Three-phase Four-wire Distribution System
    Win, Tint Soe
    Hiraki, Eiji
    Okamoto, Masayuki
    Lee, Seong Ryong
    Tanaka, Toshihiko
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, : 1560 - 1565
  • [23] A Nonlinear Controller for Neutral Point Piloted (T-Type) Multilevel Inverter-Based Three-Phase Four-Wire DSTATCOM
    Swetha, K.
    Sivachidambaranathan, V.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2022, 2022
  • [24] DSTATCOM with Reduced Switches Using Two-Leg VSC and a Zig-Zag Transformer for Power Quality Improvement in Three-Phase Four-Wire Distribution System
    Singh, Bhim
    Jayaprakash, P.
    Somayajulu, T. R.
    Kothari, D. P.
    2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 97 - +
  • [25] Simple and efficient control of DSTATCOM in three-phase four-wire polluted grid system using MCCF-SOGI based controller
    Chittora, Prakash
    Singh, Alka
    Singh, Madhusudan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (05) : 1213 - 1222
  • [26] Investigation for Harmonic Mitigation in the Line and Neutral Currents of Three-Phase Four-Wire System Feeding Two-Pulse Rectifiers with Balanced and Unbalanced Load using Zig-Zag Transformer
    Arvindan, A. N.
    Sanal, C.
    PROCEEDINGS OF THE 2014 IEEE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENERGY SYSTEMS (ICEES), 2014, : 194 - 201
  • [27] PLL-less active power filter based on one-cycle control for compensating unbalanced loads in three-phase four-wire system
    Hirve, Sachine
    Chatterjee, Kishore
    Femandes, B. G.
    Imayavaramban, M.
    Dwari, Suman
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2457 - 2465
  • [28] Adaptive Interval Type II Fuzzy Logic Controller with Interface Inductor Bank Pulse Generator Based Three-Phase Four-Wire DSTATCOM Device for Power Quality Improvement
    Alsebai M.D.
    Narayanan K.
    Pedapenki K.K.
    Periodica polytechnica Electrical engineering and computer science, 2023, 67 (02): : 113 - 135