Active noise control in a semi-closed aircraft cabin

被引:2
|
作者
Kochan K. [1 ]
Kletschkowski T. [1 ]
Sachau D. [1 ]
Breitbach H. [2 ]
机构
[1] Department of Mechatronics, Helmut-Schmidt-University, University of the Federal Armed Forces, Hamburg, Holstenhofweg 85
[2] Airbus Deutschland GmBH, Hamburg, Kreetslag 10
来源
Noise and Vibration Worldwide | 2010年 / 41卷 / 03期
关键词
Fighter aircraft - Flight control systems - Acoustic noise - Controllers - Vibration analysis - Aircraft control - Active noise control;
D O I
10.1260/0957-4565.41.3.8
中图分类号
学科分类号
摘要
An active noise control system is developed for the loadmaster area of a propeller driven transport aircraft. The loadmaster area is a small semi-enclosed volume connected to the large cargo hold. This coupling of a small room with a large room yields to new questions when an active noise control system is designed: Which effects does the coupling have on the noise field inside the small loadmaster area? Which influence do these effects have on the active noise control system? How complex is the uncertainty induced by the coupling to the large cargo? The analysis of this coupling was done in two ways. The first one, an energy based method, is used to analyze the acoustical energy flow between the loadmaster area and the cargo hold. The second one, a substructure technique, is used to study the influence on the eigenfrequencies and eigenmodes of such a coupled system. Afterwards, the theoretic results were confirmed with an experimental forced vibration analysis. The most important result is that the shape of the noise field inside the loadmaster area is less sensitive in spite of the large cargo hold. Moreover, an active noise controller was developed to handle the controller tasks. First experimental control results are given in the last section. These results have shown successful noise reduction up to 23 dB without any controller optimization.
引用
收藏
相关论文
共 50 条
  • [21] Application of active noise control to an elevator cabin
    Landaluze, J
    Portilla, I
    Pagalday, JM
    Martínez, A
    Reyero, R
    CONTROL ENGINEERING PRACTICE, 2003, 11 (12) : 1423 - 1431
  • [22] Ammonia control by ventilation in semi-closed type poultry house
    Nishina, H
    Aono, T
    Maruyama, K
    Hashimoto, Y
    AMMONIA AND ODOUR EMISSIONS FROM ANIMAL PRODUCTION FACILITIES, PROCEEDINGS, VOLS 1 AND 2, 1997, : 627 - 630
  • [23] Application of active noise control for engine related cabin noise
    Tamamura, Manpei
    Shibata, Eiji
    JSAE review, 1996, 17 (01): : 37 - 43
  • [24] Short-term annoyance reduction evoked by active noise control method on turboprop regional aircraft cabin noise
    Kiseop Yoon
    Dongwook Kim
    Soogab Lee
    Journal of Mechanical Science and Technology, 2019, 33 : 1573 - 1584
  • [25] Optimization of piezoelectric actuator grouping for aircraft cabin noise control
    Grewal, A
    Tse, D
    COLLECTION OF THE 41ST AIAA/ASME /ASCE/AHS/ASC STRUCTURES, STRUCTURAL DYNAMICS, AND MATERIALS CONFERENCE AND EXHIBIT, VOL 2, 2000, : 135 - 149
  • [26] A comparison of actuation and sensing techniques for aircraft cabin noise control
    Rossetti, DJ
    Norris, MA
    NOISE CONTROL ENGINEERING JOURNAL, 1996, 44 (01) : 53 - 58
  • [27] Short-term annoyance reduction evoked by active noise control method on turboprop regional aircraft cabin noise
    Yoon, Kiseop
    Kim, Dongwook
    Lee, Soogab
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (04) : 1573 - 1584
  • [28] Local active noise attenuation in a small piston engine aircraft cabin
    Romeu, J.
    Pamies, T.
    Genesca, M.
    Cardona, J.
    NOISE CONTROL ENGINEERING JOURNAL, 2007, 55 (06) : 516 - 525
  • [29] On the efficiency of semi-closed blast inhibitors
    Gelfand, B. E.
    Silnikov, M. V.
    Chernyshov, M. V.
    SHOCK WAVES, 2010, 20 (04) : 317 - 321
  • [30] CORE EXCITATION IN SEMI-CLOSED NUCLEI
    GOETZ, U
    HADERMAN.J
    HELVETICA PHYSICA ACTA, 1969, 42 (03): : 389 - &