A hybrid load prediction method of office buildings based on physical simulation database and LightGBM algorithm

被引:0
|
作者
Lian, Huihui [1 ,2 ]
Ji, Ying [1 ,2 ]
Niu, Menghan [1 ,2 ]
Gu, Jiefan [3 ]
Xie, Jingchao [1 ,2 ]
Liu, Jiaping [1 ,2 ]
机构
[1] Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing,100124, China
[2] College of Architecture and Civil Engineering, Beijing University of Technology, Beijing,100124, China
[3] College of Architecture and Urban Planning, Tongji University, Shanghai,201804, China
基金
中国国家自然科学基金;
关键词
Prediction models;
D O I
10.1016/j.apenergy.2024.124620
中图分类号
学科分类号
摘要
Building load prediction plays an important role in building energy savings and mechanical and electrical system optimization control. The dynamic energy consumption can be accurately calculated using the traditional physical energy simulation method that entails a complex setup and verification process due to the numerous input parameters required. It is also difficult to change the physical model once it has been determined. The data-mining method is fast in calculation and simple to use, but its prediction accuracy is limited by historical data quality. It is difficult to predict the load of new buildings without historical data. To solve these problems, this study proposes a hybrid building load prediction method for office buildings. The proposed method uses EnergyPlus to generate a building load database that includes than 25.14 million data cases, covering 35 types of building geometry and 2870 building examples. Based on the above database, the LightGBM algorithm was selected to extract feature variables that affect the load and build a load prediction model. The training results show that there are 24 key feature variables for office building load prediction. The hourly MAPE of the cooling load prediction model is 6.95 % and RMSE is 4.31 W/m2, and the hourly MAPE of the heating load prediction model is 7.09 % and RMSE is 11.64 W/m2 compared with EnergyPlus model. Two actual office buildings are selected as case studies to validate the model prediction accuracy. Results show that comparing predicted results with measured data, the hourly cooling load of the MAPE is 12.42 %. Coparing predicted results with actual heating load, daily MAPE is 7.97 %. © 2024
引用
收藏
相关论文
共 50 条
  • [31] Application of the hybrid neural network model for energy consumption prediction of office buildings
    Wang, Lize
    Xie, Dong
    Zhou, Lifeng
    Zhang, Zixuan
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [32] An agent-based simulation of occupancy schedule in office buildings
    Norouziasl, Seddigheh
    Jafari, Amirhosein
    Wang, Chao
    BUILDING AND ENVIRONMENT, 2020, 186
  • [33] pmiRScan: a LightGBM based method for prediction of animal pre-miRNAs
    Amrit Venkatesan
    Jolly Basak
    Ranjit Prasad Bahadur
    Functional & Integrative Genomics, 2025, 25 (1)
  • [34] Prediction Method of Heavy Load Wheel/Rail Wear Mechanical Properties Based on GA-BP Hybrid Algorithm
    Xue, Xiao
    Zheng, Yangbing
    Wang, Xin
    EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2022, 31 (03): : 409 - 431
  • [35] Simultaneous Load Identification Method Based on Hybrid Features and Genetic Algorithm for Nonintrusive Load Monitoring
    Yi, Shu-Hui
    Wang, Jian
    Liu, Jun-Jie
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2022, 2022
  • [36] Load Prediction Algorithm Applied with Indoor Environment Sensing in University Buildings
    Kim, Yunho
    Park, Yunha
    Seo, Hyuncheol
    Hwang, Jungha
    ENERGIES, 2023, 16 (02)
  • [37] Hybrid encryption method for biological information database based on AES and hash algorithm
    Yan, Han-Chi
    Su, Chun-Lin
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2024, 54 (10): : 2994 - 2999
  • [38] District heating load forecasting with a hybrid model based on LightGBM and FB-prophet
    Shakeel, Asim
    Chong, Daotong
    Wang, Jinshi
    JOURNAL OF CLEANER PRODUCTION, 2023, 409
  • [39] An assembly-level neutronic calculation method based on LightGBM algorithm
    Cai, Jiejin
    Li, Xuezhong
    Tan, Zhixiong
    Peng, Sitao
    ANNALS OF NUCLEAR ENERGY, 2021, 150
  • [40] Short-term cooling load prediction for office buildings based on feature selection scheme and stacking ensemble model
    Gao, Wenzhong
    Huang, Xingzong
    Lin, Mengya
    Jia, Jing
    Tian, Zhen
    ENGINEERING COMPUTATIONS, 2022, 39 (05) : 2003 - 2029