Elastic and ductile design of multi-storey crosslam massive wooden buildings under seismic actions

被引:0
|
作者
Department of Architecture, Design and Urban Planning, University of Sassari, Palazzo del Pou Salit, Piazza Duomo 6, 07041 Alghero, Italy [1 ]
不详 [2 ]
机构
来源
Eng. Struct. | / 11卷 / 3043-3053期
关键词
Compendex;
D O I
暂无
中图分类号
学科分类号
摘要
Timber
引用
收藏
相关论文
共 50 条
  • [21] ARCHITECTURAL DESIGN CRITERIA FOR MULTI-STOREY HOUSING BUILDINGS
    Kuan, Yong
    Ahmad, Yahaya
    OPEN HOUSE INTERNATIONAL, 2016, 41 (01) : 67 - 73
  • [22] Consumer housing choices among residents living in wooden multi-storey buildings
    Jussila, J.
    Franzini, F.
    Hayrinen, L.
    Lahtinen, K.
    Nagy, E.
    Mark-Herbert, C.
    Roos, A.
    Toppinen, A.
    Toivonen, R.
    HOUSING STUDIES, 2024, 39 (10) : 2654 - 2679
  • [23] Optimum seismic design of a multi-storey steel frame
    Jármai, K
    Farkas, J
    Kurobane, Y
    ENGINEERING STRUCTURES, 2006, 28 (07) : 1038 - 1048
  • [24] Seismic elastic analysis of light timber-frame multi-storey buildings: Proposal of an iterative approach
    Rossi, Simone
    Casagrande, Daniele
    Tomasi, Roberto
    Piazza, Maurizio
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 102 : 1154 - 1167
  • [25] Numerical modeling of the dynamics of multi-storey buildings with elastoplastic seismic insulators
    Zenkov, E. V.
    Sobolev, V. I.
    MECHANICAL SCIENCE AND TECHNOLOGY UPDATE (MSTU-2018), 2018, 1050
  • [26] Effect of overstrength on the seismic behaviour of multi-storey regularly asymmetric buildings
    De Stefano, Mario
    Marino, Edoardo Michele
    Rossi, Pier Paolo
    BULLETIN OF EARTHQUAKE ENGINEERING, 2006, 4 (01) : 23 - 42
  • [27] Stability of multi-storey braced steel buildings with dissipative INERD connections under seismic loading
    Vayas, I.
    Thanopoulos, P.
    Castiglioni, C.
    BAUINGENIEUR, 2007, 82 : 125 - 133
  • [28] Fire protection demands for multi-storey steel buildings in seismic areas
    Vayas, I.
    Adamopoulou, S.
    Ziogos, P.
    STEEL - A NEW AND TRADITIONAL MATERIAL FOR BUILDING, 2006, : 567 - +
  • [29] Seismic design of floor–wall joints of multi-storey CLT buildings to comply with regularity in elevation
    Davide Trutalli
    Luca Pozza
    Bulletin of Earthquake Engineering, 2018, 16 : 183 - 201
  • [30] Seismic response of irregular multi-storey buildings with flexible inelastic diaphragms
    Masi, A
    Dolce, M
    Caterina, F
    STRUCTURAL DESIGN OF TALL BUILDINGS, 1997, 6 (02): : 99 - 124