Method development of comprehensive two-dimensional liquid chromatography: A new metric for preliminary column selection

被引:1
|
作者
Tirapelle, Monica [1 ]
Duanmu, Fanyi [1 ]
Chia, Dian Ning [1 ]
Besenhard, Maximilian O. [1 ]
Mazzei, Luca [1 ]
Sorensen, Eva [1 ]
机构
[1] UCL, Dept Chem Engn, Torrington Pl, London WC1E 7JE, England
基金
英国工程与自然科学研究理事会;
关键词
Two-dimensional liquid chromatography; In-silico method development; Column orthogonality; Multi-objective optimization; Reversed-phase liquid chromatography; REVERSED-PHASE SEPARATIONS; EFFECTIVE PEAK-CAPACITY; ORTHOGONALITY; SYSTEMS; IMPURITIES; IDENTIFICATION; RESOLUTION; SPACE;
D O I
10.1016/j.chroma.2024.465593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To elevate the separation performance, two-dimensional liquid chromatography (2D-LC) uses two chromatographic columns with different stationary phases to diversify solute interactions with the resin, hence providing a second "dimension"to solute-specific separation. Developing methods for 2D-LC starts therefore with preliminary column selection. Selecting columns that yield (metaphorically) orthogonal dimensions is of utmost importance, but remains challenging. Although several metrics exist to quantify column orthogonality, currently there is no established methodology, and none of the existing methods accounts for the non-homogeneity of peak band broadening across each separation dimension. In this work, we propose anew approach to select columns a priori. This approach is based on critical resolution distribution statistics and implicitly accounts for local peak crowding and peak band broadening. Furthermore, we assess the importance of preliminary column selection during in-silico method development and multi-objective optimization of comprehensive 2D-LC. The comparison of the multi-objective Pareto fronts revealed that column pairs selected with our approach provide better separation quality and reduce analysis time compared to column selections via the most established metrics in the literature. Our results prove the importance of preliminary column selection for method development and optimization of 2D-LC systems, and they also show that choosing the right orthogonality metric (such as that proposed here) is crucial.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] LCXLC: Comprehensive two-dimensional liquid chromatography
    Majors, Ronald E.
    LC GC NORTH AMERICA, 2008, : 70 - 73
  • [22] Quantification in Comprehensive Two-Dimensional Liquid Chromatography
    Reichenbach, Stephen E.
    ANALYTICAL CHEMISTRY, 2009, 81 (12) : 5099 - 5101
  • [23] The Modulator in Comprehensive Two-Dimensional Liquid Chromatography
    Egeness, Mari J.
    Breadmore, Michael C.
    Hilder, Emily F.
    Shellie, Robert A.
    LC GC EUROPE, 2016, 29 (05) : 268 - 276
  • [24] Development of on-line comprehensive two-dimensional liquid chromatography method for the separation of biomass compounds
    Le Masle, Agnes
    Angot, David
    Gouin, Cecile
    D'Attoma, Amelie
    Ponthus, Jeremie
    Quignard, Alain
    Heinisch, Sabine
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1340 : 90 - 98
  • [25] Likelihood of total resolution in liquid chromatography: Evaluation of one-dimensional, comprehensive two-dimensional, and selective comprehensive two-dimensional liquid chromatography
    Davis, Joe M.
    Stoll, Dwight R.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1360 : 128 - 142
  • [26] Comprehensive Two-dimensional Liquid Chromatography (LCxLC): A Review
    Kivilompolo, Maarit
    Pol, Jaroslav
    Hyotylainen, Tuulia
    LC GC EUROPE, 2011, 24 (05) : 232 - +
  • [27] Comprehensive two-dimensional liquid chromatography of heavy oil
    van Beek, Fleur T.
    Edam, Rob
    Pirok, Bob W. J.
    Genuit, Wim J. L.
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1564 : 110 - 119
  • [28] A simple method for the determination of peak distribution in comprehensive two-dimensional liquid chromatography
    Dueck, Roman
    Sonderfeld, Hannah
    Schmitz, Oliver J.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1246 : 69 - 75
  • [29] Programmed elution in comprehensive two-dimensional liquid chromatography
    Jandera, Pavel
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 : 112 - 129
  • [30] CHROMATOGRAPHY WITH A TWO-DIMENSIONAL COLUMN
    GUIOCHON, G
    GONNORD, MF
    ZAKARIA, M
    BEAVER, LA
    SIOUFFI, AM
    CHROMATOGRAPHIA, 1983, 17 (03) : 121 - 124