Method development of comprehensive two-dimensional liquid chromatography: A new metric for preliminary column selection

被引:1
|
作者
Tirapelle, Monica [1 ]
Duanmu, Fanyi [1 ]
Chia, Dian Ning [1 ]
Besenhard, Maximilian O. [1 ]
Mazzei, Luca [1 ]
Sorensen, Eva [1 ]
机构
[1] UCL, Dept Chem Engn, Torrington Pl, London WC1E 7JE, England
基金
英国工程与自然科学研究理事会;
关键词
Two-dimensional liquid chromatography; In-silico method development; Column orthogonality; Multi-objective optimization; Reversed-phase liquid chromatography; REVERSED-PHASE SEPARATIONS; EFFECTIVE PEAK-CAPACITY; ORTHOGONALITY; SYSTEMS; IMPURITIES; IDENTIFICATION; RESOLUTION; SPACE;
D O I
10.1016/j.chroma.2024.465593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To elevate the separation performance, two-dimensional liquid chromatography (2D-LC) uses two chromatographic columns with different stationary phases to diversify solute interactions with the resin, hence providing a second "dimension"to solute-specific separation. Developing methods for 2D-LC starts therefore with preliminary column selection. Selecting columns that yield (metaphorically) orthogonal dimensions is of utmost importance, but remains challenging. Although several metrics exist to quantify column orthogonality, currently there is no established methodology, and none of the existing methods accounts for the non-homogeneity of peak band broadening across each separation dimension. In this work, we propose anew approach to select columns a priori. This approach is based on critical resolution distribution statistics and implicitly accounts for local peak crowding and peak band broadening. Furthermore, we assess the importance of preliminary column selection during in-silico method development and multi-objective optimization of comprehensive 2D-LC. The comparison of the multi-objective Pareto fronts revealed that column pairs selected with our approach provide better separation quality and reduce analysis time compared to column selections via the most established metrics in the literature. Our results prove the importance of preliminary column selection for method development and optimization of 2D-LC systems, and they also show that choosing the right orthogonality metric (such as that proposed here) is crucial.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A guide of column selection for two-dimensional liquid chromatography method development of natural alkaloids
    Xu, Yang
    Liu, Yanfang
    Zhou, Han
    Wang, Rong
    Yu, Dongping
    Guo, Zhimou
    Liang, Xinmiao
    TALANTA, 2023, 251
  • [2] Development of a resolution metric for comprehensive two-dimensional chromatography
    Peters, Sonja
    Vivo-Truyols, Gabriel
    Marriott, Philip J.
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1146 (02) : 232 - 241
  • [3] Development of a predictive screening method for selection of two-dimensional liquid chromatography column pair combinations
    Lindsey, Rebecca
    Stoll, Dwight
    Carr, Peter
    Siepmann, Joern
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [4] Column selection for comprehensive two-dimensional liquid chromatography using the hydrophobic subtraction model
    Lindsey, Rebecca K.
    Eggimann, Becky L.
    Stoll, Dwight R.
    Carr, Peter W.
    Schure, Mark R.
    Siepmann, J. Ilja
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1589 : 47 - 55
  • [5] Column Selection and Optimization for Comprehensive Two-Dimensional Gas Chromatography: A Review
    Mommers, John
    van der Wal, Sjoerd
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 51 (02) : 183 - 202
  • [6] Theories to support method development in comprehensive two-dimensional liquid chromatography - A review
    Bedani, Filippo
    Schoenmakers, Peter J.
    Janssen, Hans-Gerd
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (14) : 1697 - 1711
  • [7] Comprehensive two-dimensional liquid chromatography
    Mondello, Luigi
    Dugo, Paola
    Donato, Paola
    Herrero, Miguel
    Montero, Lidia
    Schmitz, Oliver J.
    NATURE REVIEWS METHODS PRIMERS, 2023, 3 (01):
  • [8] Comprehensive two-dimensional liquid chromatography
    Nature Reviews Methods Primers, 3 (1):
  • [9] Comprehensive two-dimensional liquid chromatography
    Luigi Mondello
    Paola Dugo
    Paola Donato
    Miguel Herrero
    Lidia Montero
    Oliver J. Schmitz
    Nature Reviews Methods Primers, 3
  • [10] Comprehensive two-dimensional liquid chromatography
    Robert A. Shellie
    Paul R. Haddad
    Analytical and Bioanalytical Chemistry, 2006, 386 : 405 - 415