Nonlinear effect in a thermoacoustic refrigerator

被引:0
|
作者
State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China [1 ]
机构
来源
Kung Cheng Je Wu Li Hsueh Pao | 2008年 / 12卷 / 1990-1992期
关键词
Experimental apparatus - High amplitudes - High harmonics - Nonlinear effect - Thermoacoustic effects - Thermoacoustic refrigeration - Thermoacoustic refrigerators - Wave amplitudes;
D O I
暂无
中图分类号
学科分类号
摘要
Thermoacoustic refrigerators based on thermoacoustic effect generally work with high amplitude sound waves, which could go with intense nonlinearities. In present work, an experimental apparatus of thermoacoustic refrigeration was built up to investigate the effect of stacks on nonlinearities and the effect of nonlinearities on the performance of thermoacoustic refrigerator. Experimental results indicate that while with stacks in the resonator, acoustic wave amplitudes are weakened, pressure ratios are cut down by 5%, high harmonic amplitudes and growth rates are decreased compared with the case of no stacks; nonlinear effect stabilizes the sound wave and causes the production of high harmonics, moreover, both the growth rates of sound wave and high harmonics are tend to be flat; the thermoacoustic effect is obvious while with stacks in the resonator, and no-load temperatures are increased first and decreased then as the acoustic powers are increased, which reach the lowest value 5.1C while the acoustic power is 50 W.
引用
收藏
相关论文
共 50 条
  • [21] Thermoacoustic Refrigerator for High Temperature Gradient
    Mishra, Abhishek
    Choudhary, Ankur Kumar
    Tomar, Taniya
    Korody, Jagannath
    INTERNATIONAL CONFERENCE ON RESEARCH IN MECHANICAL ENGINEERING SCIENCES (RIMES 2017), 2018, 144
  • [22] Thermoelectric power generation in a thermoacoustic refrigerator
    Slaton, WV
    Zeegers, JCH
    APPLIED ACOUSTICS, 2006, 67 (05) : 450 - 460
  • [23] Condensation in a steady-flow thermoacoustic refrigerator
    Hiller, R.A.
    Swift, G.W.
    1600, American Institute of Physics Inc. (108):
  • [24] Influence of stack geometry on the performance of thermoacoustic refrigerator
    B Ramesh Nayak
    G Pundarika
    Bheemsha Arya
    Sādhanā, 2017, 42 : 223 - 230
  • [25] Measurement of performance and heat transport in thermoacoustic refrigerator
    Kim, WT
    Song, KJ
    Choi, MY
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 971 - 976
  • [26] Numerical investigation of thermoacoustic refrigerator at weak and large amplitudes considering cooling effect
    Namdar, Ali
    Kianifar, Ali
    Roohi, Ehsan
    CRYOGENICS, 2015, 67 : 36 - 44
  • [27] The impact of gas blockage on the performance of a thermoacoustic refrigerator
    Akhavanbazaz, Masoud
    Siddiqui, M. H. Kamran
    Bhat, Rama B.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (01) : 231 - 239
  • [28] OPTIMIZATION OF A THERMOACOUSTIC REFRIGERATOR WITH AN EVOLUTIONARY ALGORITHM APPROACH
    Zolpakar, Nor Atiqah
    Mohd-Ghazali, Normah
    JURNAL TEKNOLOGI, 2016, 78 (9-2): : 19 - 24
  • [29] Design and simulation of a small capacity thermoacoustic refrigerator
    Kajurek, Jakub
    Rusowicz, Artur
    Grzebielec, Andrzej
    SN APPLIED SCIENCES, 2019, 1 (06):
  • [30] Optimized Heat Exchanger Unit in a Thermoacoustic Refrigerator
    El-Fawal, Mawahib Hassan
    Mohd-Ghazali, Normah
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 1300 - 1308