Non-contact imaging of subsurface defects using a scanning laser source

被引:0
|
作者
Hayashi, Takahiro [1 ]
Mori, Naoki [1 ]
Ueno, Tomotake [1 ]
机构
[1] Department of Mechanical Engineering, Graduate School of Engineering, Osaka University, Suita,Osaka,565-0871, Japan
基金
日本学术振兴会;
关键词
Aluminum alloys - Ultrasonic testing - Nondestructive examination - Scanning - Defects - Signal to noise ratio;
D O I
暂无
中图分类号
学科分类号
摘要
The quality of additive manufacturing (AM) components must be guaranteed to ensure wide applicability, and a nondestructive inspection technology is required in this regard. Therefore, this study examined a method for detecting subsurface defects using ultrasonic waves excited by a laser. Fundamental experiments showed that wideband ultrasonic waves can be excited with a suitable signal-to-noise ratio using high-repetition laser pulses. Images of subsurface defects were appropriately obtained using a scanning laser source (SLS) with broadband waves for an aluminum alloy flat plate with artificial defects. The imaging experiments showed that the acquisition condition depends on the local defect resonant (LDR) frequency in the defective part. The imaging technique also enabled to detect subsurface circular defects created by AM with the diameter below 1.0 mm that were undetectably small in our previous study using the SLS. Based on results of these experiments and a finite element analysis, the following guideline is proposed: the LDR frequencies of targeted defects must be included in the tested frequency range. © 2021
引用
收藏
相关论文
共 50 条
  • [21] Non-contact ultra-widefield imaging of retinopathy of prematurity using the Optos dual wavelength scanning laser ophthalmoscope
    C K Patel
    T H M Fung
    M M K Muqit
    D J Mordant
    J Brett
    L Smith
    E Adams
    Eye, 2013, 27 : 589 - 596
  • [22] Non-contact ultra-widefield imaging of retinopathy of prematurity using the Optos dual wavelength scanning laser ophthalmoscope
    Patel, C. K.
    Fung, T. H. M.
    Muqit, M. M. K.
    Mordant, D. J.
    Brett, J.
    Smith, L.
    Adams, E.
    EYE, 2013, 27 (05) : 589 - 596
  • [23] Quantitative sub-surface and non-contact imaging using scanning microwave microscopy
    Gramse, Georg
    Brinciotti, Enrico
    Lucibello, Andrea
    Patil, Samadhan B.
    Kasper, Manuel
    Rankl, Christian
    Giridharagopal, Rajiv
    Hinterdorfer, Peter
    Marcelli, Romolo
    Kienberger, Ferry
    NANOTECHNOLOGY, 2015, 26 (13)
  • [24] Non-contact ultrasonic characterization of defects using EMATs
    Edwards, RS
    Dixon, S
    Jian, X
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 24A AND 24B, 2005, 760 : 1568 - 1575
  • [25] Non-contact tonometry using laser interferometry
    Drescher, J
    Stork, W
    Hey, S
    Gundlach, A
    Glaser, KDM
    Kreiner, C
    MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, CARDIOLOGY, OPHTHALMOLOGY, AND DENTISTRY II, PROCEEDINGS OF, 1999, 3564 : 122 - 130
  • [26] Non-contact detection of subsurface defects in metallic bars with small diameter using laser-generated Rayleigh waves: From localization to quantification
    Zhang, Yanjie
    Xu, Zhiqi
    Wang, Tao
    Chen, Dan
    Wang, Wei
    Liang, Mengting
    Li, Jiadong
    JOURNAL OF MANUFACTURING PROCESSES, 2024, 124 : 1410 - 1421
  • [27] Non-contact physical stress measurement using thermal imaging and blind source separation
    Hong, Kan
    OPTICAL REVIEW, 2020, 27 (01) : 116 - 125
  • [28] Non-contact physical stress measurement using thermal imaging and blind source separation
    Kan Hong
    Optical Review, 2020, 27 : 116 - 125
  • [29] Imaging and non-contact profile analysis of Nd:YAG laser-irradiated teeth by scanning electron microscopy and confocal laser scanning microscopy
    Yamada, MK
    Watari, F
    DENTAL MATERIALS JOURNAL, 2003, 22 (04) : 556 - 568
  • [30] Non-contact in vivo diffuse optical imaging using a time-gated scanning system
    Mazurenka, M.
    Di Sieno, L.
    Boso, G.
    Contini, D.
    Pifferi, A.
    Dalla Mora, A.
    Tosi, A.
    Wabnitz, H.
    Macdonald, R.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (10): : 2257 - 2268