A one-dimensional position-sensitive ionization chamber has been designed and fabricated. The cathode of this ionization chamber consists of two selfsame units that are insulated from each other and each unit is divided into two-way cleft plates. From current output signals, it can offer the intensity and position of X-ray beam. The ionization chamber was installed on a SSRF macromolecular crystallography beamline and its performance was tested. In the test, a standard ionization chamber was used for thecomparison of beam intensity measurement. The one-dimensional position-sensitive ionization chamber was fixed on a high precision linear motor stage and was driven on horizontal direction to scan the beam position step by step, in which the beam energy was set to be 8 keV and the scanning range to be 10 mm. The position scan was repeated 12 times. The tested specifications were plateau curves, linearity, position resolution and the intensity of beam. The results indicate that the 1-D position-sensitive ionization chamber has a good linearity and its position resolution is better than 20 μm and linear measuring range is 6 mm. Moreover, it will be installed on the beamline of SSRF for monitoring the stability of beam.
引用
收藏
页码:544 / 551
相关论文
共 50 条
  • [31] THE PERFORMANCE OF A POSITION-SENSITIVE WIRE CHAMBER IN THE PRESENCE OF A MAGNETIC-FIELD
    BOWER, CR
    GEBHARD, MW
    HEINZ, RM
    MUSSER, JA
    PITTS, JJ
    MILLER, JL
    MUFSON, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (01): : 37 - 46
  • [32] UTILIZING A POSITION-SENSITIVE WIRE CHAMBER IN SHEET DENSITY-MEASUREMENTS
    LAAKSO, M
    KOPONEN, J
    RITALA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (03): : 459 - 461
  • [33] INTEGRAL TYPE POSITION-SENSITIVE PROPORTIONAL CHAMBER WITH MULTIPLEXER READOUT SYSTEM
    HASEGAWA, K
    MOCHIKI, K
    SEKIGUCHI, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (04) : 3660 - 3664
  • [34] Heavy ion ERD of nitrides with a position-sensitive gas ionization detector
    Timmers, H
    Weijers, TDM
    Elliman, RG
    Ophel, TR
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2001, 576 : 487 - 490
  • [35] Development of a neutron detector based on a position-sensitive photomultiplier
    Hirota, K
    Shinohara, T
    Ikeda, K
    Mishima, K
    Adachi, T
    Morishima, T
    Satoh, S
    Oku, T
    Yamada, S
    Sasao, H
    Suzuki, J
    Shimizu, HM
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2005, 7 (08) : 1836 - 1838
  • [36] Development of position-sensitive proton recoil telescope (PSPRT)
    Miura, T
    Baba, M
    Kawata, N
    Aoki, T
    Hagiwara, M
    Hiroishi, T
    Sanami, T
    Nishitani, T
    Hori, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 493 (1-2): : 99 - 105
  • [37] Development of a position-sensitive detector for TOF-PET
    Moriya, T.
    Omura, T.
    Watanabe, M.
    Yamashita, T.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2842 - 2846
  • [38] Design and development of 1 mm resolution PET detectors with position-sensitive PMTs
    Shao, YP
    Cherry, SR
    Chatziioannou, AF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 486 - 490
  • [39] Development of large area and of position-sensitive timing RPCs
    Blanco, A
    Marques, RF
    Finck, C
    Fonte, P
    Gobbi, A
    Mendiratta, SK
    Monteiro, J
    Policarpo, A
    Rozas, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2): : 170 - 175
  • [40] Development of a position-sensitive detector for UCN Using CCD
    ICEPP, University of Tokyo
    不详
    不详
    KURRI Prog Rep, 2006, (170):