Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter

被引:0
|
作者
Endarko E. [1 ]
Pitaloka A.W. [1 ]
Inayah A.A. [1 ]
Ramadhan F.R. [1 ]
Kardianto K. [2 ]
Rahayuningsih B. [2 ]
机构
[1] Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS-Sukolilo, East Java, Surabaya
[2] Balai Pengamanan Fasilitas Kesehatan Gubeng, East Java, Surabaya
来源
关键词
Calibration; Dosimetry; Phantom; Radiation; Thermoluminescent Dosimetry;
D O I
10.31661/jbpe.v0i0.2109-1401
中图分类号
学科分类号
摘要
Background: Calibration of Thermo Luminescent Dosimetry (TLD) in eye lens dosimeter requires a standard phantom. The use of anthropomorphic phantoms in calibration needs evaluation. Objective: This study aimed to analyze the angular response of the TLD on the fabricated 3D anthropomorphic head phantom and Computerized Imaging Reference Systems (CIRS)-Computed Tomography (CT) dose phantom as a standard phantom irradiated with Cs-137 and to compare the absorbed dose and linear attenuation for both phantoms. Hp (3) analysis, conversion coefficient (hpK (3)), and calibration factor (CF) are also investigated. Material and Methods: In this experimental study, the fabricated 3D printed anthropomorphic head phantom was analyzed using polylactic acid (PLA) with the skull and then filled with the artificial brain and cerebrospinal fluid (CSF) as a test phantom. TLD-700H and TLD Reader Harshaw 6600 plus were used to analyze the angular response of Cs-137 radiation and to determine the absorbed dose and linear attenuation coefficient of test and standard phantoms. Results: The effect of the angle of radiation source towards TLD reading at the anthropomorphic head phantom has a similar value to the standard phantom with a calibration factor ranging from 0.82 to 1. The absorbed dose measurement and the linear attenuation coefficient of the anthropomorphic head phantom with the standard phantom have different values of 2.52 and 3.78%, respectively. Conclusion: The fabricated 3D printed anthropomorphic head phantom has good potential as an alternative to standard phantoms for TLD calibration in eye lens do-simeter. © 2023, Shiraz University of Medical Sciences. All rights reserved.
引用
收藏
页码:193 / 202
页数:9
相关论文
共 50 条
  • [1] Evaluation of a 3D printed OSL eye lens dosimeter for photon dosimetry
    Santos, M. F.
    Filho, W. C., V
    Melo, G. T. P.
    Asfora, V. K.
    Khoury, H. J.
    Barros, V. S. M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1247 - 1257
  • [2] Validation of spine SBRT using a 3D printed Anthropomorphic phantom
    Dekker, K. H.
    Alexander, K. M.
    de Moraes, F. Ynoe
    Olding, T.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [3] Dual-Material 3D Printing of An Anthropomorphic Head Phantom
    Peters, M.
    Craft, D.
    Baltz, G.
    Followill, D.
    Howell, R.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [4] Patient-Specific Partial Volume Corrections Using a 3D Printed Anthropomorphic Head and Neck Phantom
    Adam, D.
    Marsh, I.
    Bradshaw, T.
    Hill, P.
    Cox, B.
    Grudzinski, J.
    Harari, P.
    Bednarz, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E472 - E472
  • [5] Development of level 3 3D dosimetry audit using PRESAGE dosimeter in bespoke anthropomorphic phantom
    Mohyedin, Muhammad Zamir
    Zin, Hafiz
    Rahman, Ahmad Taufek Abdul
    RADIOTHERAPY AND ONCOLOGY, 2024, 197 : S306 - S308
  • [6] A 3D Printed Anthropomorphic Phantom for Validating Quantitative SIRT Imaging in Multicentre Trials
    Gear, J.
    Cummings, C.
    Tapner, M.
    Flux, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S756 - S757
  • [7] A radiopaque 3D printed, anthropomorphic phantom for simulation of CT-guided procedures
    Paul Jahnke
    Felix Benjamin Schwarz
    Marco Ziegert
    Tobias Almasi
    Owais Abdelhadi
    Maximilian Nunninger
    Bernd Hamm
    Michael Scheel
    European Radiology, 2018, 28 : 4818 - 4823
  • [8] A radiopaque 3D printed, anthropomorphic phantom for simulation of CT-guided procedures
    Jahnke, Paul
    Schwarz, Felix Benjamin
    Ziegert, Marco
    Almasi, Tobias
    Abdelhadi, Owais
    Nunninger, Maximilian
    Hamm, Bernd
    Scheel, Michael
    EUROPEAN RADIOLOGY, 2018, 28 (11) : 4818 - 4823
  • [9] Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT
    Hernandez-Giron, Irene
    den Harder, Johan Michiel
    Streekstra, Geert J.
    Geleijns, Jacob
    Veldkamp, Wouter J. H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 47 - 57
  • [10] Study of PRESAGE® dosimeter for end-to-end 3D radiotherapy verification using an anthropomorphic phantom with bespoke dosimeter insert
    Mohyedin, Muhammad Zamir
    Zin, Hafiz Mohd
    Abubakar, Auwal
    Rahman, Ahmad Taufek Abdul
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 955 - 966