Model Test Study on Deformation and Failure of Metro Shield Tunnel under Normal Faulting

被引:0
|
作者
Li, Hanyuan [1 ,2 ]
Li, Xinggao [1 ,2 ]
Wang, Jie [1 ,2 ]
Yang, Yi [1 ,2 ]
Liu, Hao [3 ]
机构
[1] Key Laboratory of Urban Underground Engineering, Ministry of Education, Beijing Jiaotong University, Beijing,100044, China
[2] School of Civil Engineering, Beijing Jiaotong University, Beijing,100044, China
[3] Jinan Rail Transit Group Co. Ltd., Jinan,250101, China
基金
中国国家自然科学基金;
关键词
Faulting - Fracture - Fracture mechanics - Shielding - Structural design - Tunnel linings;
D O I
10.16339/j.cnki.hdxbzkb.2024049
中图分类号
学科分类号
摘要
To reveal the deformation and failure characteristics of the metro shield tunnel overpassing buried fault, a self-designed loading test device for faulting simulation was used to carry out a 1∶25 geometric scale cross-fault shield tunnel model test. The mechanical response law and deformation failure characteristics of the shield tunnel under normal faulting were analyzed. The test results show that under 2 cm normal faulting, the longitudinal differential deformation of the tunnel shows a nonlinear increasing trend. The opening of the circumferential joint is mainly located at the vault of the footwall tunnel. The arch bottom of the hanging wall tunnel and the peak opening of the circumferential joints have exceeded the waterproof limit of the joints. The diameter convergence deformation of the segment lining at the junction of the fault extension line and the tunnel occurs severely. The stress state of the outer side of the arch waist of the tunnel lining is tensioned, while the outer side of the vault and the arch waist are compressed. The contact pressure between the tunnel and the stratum is greatly affected by the faulting, and there are surrounding rock compression and loosening zones. However, the peak value of contact pressure is relatively limited. Tensile fracture of the circumferential joint, longitudinal cracking of the segment, and joint deformation are the main deformation and failure characteristics of the shield tunnel. The probability of oblique shear failure and local crushing failure is low. Based on the longitudinal deformation and failure characteristics of shield tunnels, the joints deformation and the tensile fracture of the circumferential joint should be taken as the main control indexes to define the structural failure of cross-fault shield tunnels. Based on the deformation and failure characteristics of segmental lining, suggestions on structural design and countermeasures of cross-fault shield tunnel are proposed. © 2024 Hunan University. All rights reserved.
引用
收藏
页码:76 / 87
相关论文
共 50 条
  • [11] Deformation and failure analysis of metro shield tunnel induced by active ground fissure in Xi'an, China
    Li, Chenyang
    Huang, Qiangbing
    Gou, Yuxuan
    Yan, Yufeng
    Miao, Chenyang
    Wang, Youlin
    Jia, Shaochun
    ENGINEERING FAILURE ANALYSIS, 2022, 142
  • [12] Analysis on Influence Factors of Longitudinal Deformation of Metro Shield Tunnel
    Li, Lixin
    Zhao, Fang
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 : 172 - 176
  • [13] Model test of twin-bore metro station constructed with expanding shield tunnel
    Li, Wei
    He, Chuan
    Zhang, Hai-Bo
    Yantu Lixue/Rock and Soil Mechanics, 2008, 29 (12): : 3261 - 3265
  • [14] Model test of twin-bore metro station constructed with expanding shield tunnel
    Li Wei
    He Chuan
    Zhang Hai-bo
    ROCK AND SOIL MECHANICS, 2008, 29 (12) : 3261 - 3265
  • [15] Model test study on failure mode of segment structure of shield tunnel with crack length
    Liu C.
    He C.
    Wang S.
    Ma G.
    Guo W.
    Lu D.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2019, 50 (06): : 1447 - 1456
  • [16] Deformation Characterisation and Distress Diagnosis of a Metro Shield Tunnel by Adjacent Constructions
    Liu, Ting-jin
    Chen, Si-wei
    Liu, Hong-yuan
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [17] Model test for influence of ground fissure profile pattern on deformation of metro tunnel
    Li Kai-ling
    Men Yu-ming
    Liu Yang
    Jiang Rong
    ROCK AND SOIL MECHANICS, 2011, 32 (06) : 1690 - 1696
  • [18] Model test study on the deformation and failure characteristics of mountain tunnel under a strike-slip fault dislocation
    Gao, Jiaqing
    Wang, Qiyao
    Wang, Rui
    Yang, Jun
    Yang, Yawu
    STRUCTURES, 2024, 60
  • [19] Discussion on deformation and failure of segmental metro tunnel linings
    Liu, Xian
    Zhang, Yumeng
    Wang, Rulu
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2020, 53 (05): : 118 - 128
  • [20] Investigation of deformation of shield tunnel based on large-scale model test
    Tsuno, K.
    Kinoshita, K.
    Ushida, T.
    Tunnels and Underground Cities: Engineering and Innovation meet Archaeology, Architecture and Art- Proceedings of the WTC 2019 ITA-AITES World Tunnel Congress, 2019, : 3262 - 3269