Voltammetric Determination of Pyridoxine in Pharmaceutical Samples Using Phosphorus-Doped Copper Oxide Pencil Graphite Electrode

被引:0
|
作者
Acikalin, Merve Yalcin [1 ]
Dokur, Ebrar [1 ]
Uruc, Selen [1 ,2 ]
Gorduk, Ozge [1 ]
Sahin, Yucel [1 ]
机构
[1] Yildiz Tech Univ, Fac Arts & Sci, Dept Chem, TR-34220 Istanbul, Turkiye
[2] Biruni Univ, Fac Pharm, Dept Basic Pharmaceut Sci, Istanbul, Turkiye
关键词
pyridoxine; sensor; differential pulse voltammetry; copper nanoparticles; over-oxidation; GLASSY-CARBON ELECTRODE; VITAMIN-B-6; MELATONIN; SENSOR; ASSAY; ACID;
D O I
10.1149/1945-7111/ad9015
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A phosphorus-doped copper oxide/pencil graphite electrode (P-doped CuO/PGE) was developed to determine pyridoxine selectively. The phosphorus-doped into the copper has revealed a large number of defects that can provide active sites for the reaction to take place, thus contributing to the improvement of the electrical conductivity of copper oxide. Cyclic voltammetry, electrochemical impedance spectroscopy, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy were employed for the characterization of the P-doped CuO/PGE. Surface morphology was analyzed by field emission scanning electron microscopy. Electrochemical measurements were performed by differential pulse voltammetry, and the limit of detection (LOD) and limit of quantification values for pyridoxine were calculated. The LOD value was 0.33 mu mol L-1 with a linear range of 1.0 and 100 mu mol L-1. The developed sensor showed a remarkable anti-interference effect against interference from ascorbic acid, dopamine, glucose, uric acid, and lactate. Potential interference effects of species that may coexist with pyridoxine in pharmacological samples were also investigated. The applicability of the developed sensor to real samples was examined, and satisfactory recovery values were obtained.<br />
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Piroxicam voltammetric determination by ultra low cost pencil graphite electrode
    Lopes de Macedo, Isaac Yves
    Alecrim, Morgana Fernandes
    Oliveira Neto, Jeronimo Raimundo
    Sapateiro Torres, Ieda Maria
    Thomaz, Douglas Vieira
    Gil, Eric de Souza
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 56
  • [22] Anodic stripping voltammetric determination of vardenafil hydrochloride at pencil graphite electrode
    Aydin, Zehra Yazar
    Yaman, Yesim Tugce
    Yasacan, Merve
    Cirak, Tamer
    Abaci, Serdar
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (04) : 803 - 810
  • [23] Anodic stripping voltammetric determination of vardenafil hydrochloride at pencil graphite electrode
    Zehra Yazar Aydın
    Yesim Tugce Yaman
    Merve Yaşacan
    Tamer Çırak
    Serdar Abacı
    Journal of the Iranian Chemical Society, 2017, 14 : 803 - 810
  • [24] Differential Pulse Voltammetric Determination of Levodopa in Pharmaceutical and Biological Samples using NiO/graphene Oxide Nanocomposite Modified Graphite Screen Printed Electrode
    Moghaddam, Hadi Mahmoudi
    Malakootian, Mahsa
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (05): : 520 - 530
  • [25] Voltammetric Determination of Amoxicillin Using a Reduced Graphite Oxide Nanosheet Electrode
    Pham, Thi Hai Yen
    Mai, Thi Trang
    Nguyen, Hoang Anh
    Chu, Thi Thu Hien
    Vu, Thi Thu Ha
    Le, Quoc Hung
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2021, 2021
  • [26] Voltammetric Determination of Acrylamide Using Coal Tar Pitch Modified Pencil Graphite Electrode by SWV
    Şeyma Korkmaz
    Wael Bosnali
    İbrahim Ender Mülazımoğlu
    Ayşen Demir Mülazımoğlu
    Food Analytical Methods, 2023, 16 : 1738 - 1745
  • [27] Voltammetric Determination of Acrylamide Using Coal Tar Pitch Modified Pencil Graphite Electrode by SWV
    Korkmaz, Seyma
    Bosnali, Wael
    Mulazimoglu, Ibrahim Ender
    Mulazimoglu, Aysen Demir
    FOOD ANALYTICAL METHODS, 2023, 16 (11-12) : 1738 - 1745
  • [28] Electrooxidation of thiourea and its square-wave voltammetric determination using pencil graphite electrode
    Levent, Abdulkadir
    Keskin, Ertugrul
    Yardim, Yavuz
    Senturk, Zuhre
    REVIEWS IN ANALYTICAL CHEMISTRY, 2011, 30 (01) : 45 - 51
  • [29] Voltammetric Determination of Hemoglobin Using a Pencil Lead Electrode
    Majidi, Mir Reza
    Saadatirad, Afsaneh
    Alipour, Esmaeel
    ELECTROANALYSIS, 2011, 23 (08) : 1984 - 1990
  • [30] Voltammetric Determination of Boron using Poly Xylenol Orange-Modified Pencil Graphite Electrode
    Liv, Lokman
    Nakiboglu, Nuri
    ANALYTICAL LETTERS, 2018, 51 (1-2) : 170 - 185