Effect of localized dry-out on startup and steady-state operation characteristics of ethanol-based oscillating heat pipes

被引:0
|
作者
Ying, Liu [1 ,2 ]
Yan, Yuhao [1 ]
Bao, Kangli [1 ]
Wu, Xilei [1 ]
Yang, Jialiang [1 ]
Ning, Jiang [1 ]
Han, Xiaohong [1 ,2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Zhejiang Key Lab Clean Energy & Carbon Neutral, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat transfer distance; Localized dry-out; Multi-stage operation; Dry-out characteristics; Oscillating heat pipe; THERMAL PERFORMANCE; SECTION;
D O I
10.1016/j.applthermaleng.2024.124420
中图分类号
O414.1 [热力学];
学科分类号
摘要
It's a significant challenge to choose a suitable heat dissipation method in different electronics assembly environments requiring different heat transfer distances. Oscillating heat pipes are promising heat exchangers, but localized dry-out during operation leads to an unstable heat transfer and limits further application of oscillating heat pipes. To extend the applicability of oscillating heat pipes, it is essential to reveal the localized dry-out characteristics under various heat transfer distances. In this study, the impact of localized dry-out on the multi-stage operating characteristics of ethanol-oscillating heat pipes with various heat transfer distances was investigated through partial visualization experiments. The anti-dry-out capacity of ethanol-oscillating heat pipes was quantitatively evaluated and compared with that of water-oscillating heat pipes. The experimental results revealed that the dry-out performance was closely related to the flow motion of the operating fluid. The stagnation of the operating fluid was the primary cause of localized dry-out. Localized dry-out deteriorated the startup and heat transfer performances of oscillating heat pipes. The anti-dry-out capacity first improved and then diminished as the heat transfer distance increased. The results also revealed that ethanol exhibited superior dry-out performance compared to water, especially at long heat transfer distances. Besides, an empirical correlation equation was fitted to evaluate the anti-dry-out capacity of oscillating heat pipes under different heat transfer distances based on the experimental results. The empirical correlation equation about the Ku number could be a reasonable predictor of the anti-dry-out capacity of oscillating heat pipes. The predicted results were in good agreement with the experimental results, with 86 % of the data deviating within +/- 20 % and an average standard deviation of 19.72 %. This research closed the gap in the prediction for the anti-dry-out capacity and provided a valuable reference to broaden the applicability of oscillating heat pipes.
引用
收藏
页数:13
相关论文
共 16 条
  • [1] DRY-OUT CHARACTERISTICS OF HEAT PIPES
    KURAMAE, M
    MATSUMOTO, M
    KAGAKU KOGAKU RONBUNSHU, 1984, 10 (06) : 736 - 743
  • [2] Salt loaded heat pipes: steady-state operation and related heat and mass transport
    Simakin, A
    Ghassemi, A
    EARTH AND PLANETARY SCIENCE LETTERS, 2003, 215 (3-4) : 411 - 424
  • [3] Numerical and experimental investigation of the steady-state performance characteristics of loop heat pipes
    Jazebizadeh, Hooman
    Kaya, Tarik
    APPLIED THERMAL ENGINEERING, 2020, 181 (181)
  • [4] Dry-out limit enhancement strategy in sodium heat pipes: Overfilling effect and modified capillary limit model
    Lee, Dong Hun
    Bang, In Cheol
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 228
  • [5] EFFECT OF LOW WICK PERMEABILITY ON TRANSIENT AND STEADY-STATE PERFORMANCE OF HEAT PIPES
    Chen, Q.
    Huang, Y.
    HEAT TRANSFER RESEARCH, 2019, 50 (13) : 1319 - 1332
  • [6] Experimental study on steady-state operating characteristics of gravity-assisted loop heat pipes
    Bai, Lizhan
    Lin, Guiping
    Zhang, Hongxing
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2008, 29 (05): : 1112 - 1117
  • [7] Steady-state operating characteristics analysis of loop heat pipes with flat-plate evaporator
    Li, Changzheng
    Liu, Zheng
    Zhang, Xiantao
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 28
  • [8] Self-humidification characteristics of steady-state operation and startup for humidifier-free polymer electrolyte membrane fuel cell
    Wang, Ning
    Hu, Baobao
    Pang, Yiheng
    Qu, Zhiguo
    Wang, Yun
    ENERGY, 2025, 320
  • [9] Analytical steady-state model based on Fourier integral transforms for cylindrical heat pipes under axisymetric conditions
    Blet, Nicolas
    Maillet, Denis
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 183
  • [10] A Localized Collocation Method Based on Nonsingular Fundamental Solutions for Steady-State Heat Conduction Analysis in Heterogeneous Materials
    Liu, Shuainan
    Fu, Zhuojia
    Liu, Qingguo
    Zhao, Haitao
    INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS, 2024,