Dry-out limit enhancement strategy in sodium heat pipes: Overfilling effect and modified capillary limit model

被引:1
|
作者
Lee, Dong Hun [1 ]
Bang, In Cheol [1 ]
机构
[1] Ulsan Natl Inst Sci & Technol UNIST, Dept Nucl Engn, 50 UNIST Gil, Ulsan 44919, South Korea
基金
新加坡国家研究基金会;
关键词
Heat pipe; Capillary limit; Filling ratio; Microreactor; Liquid metal;
D O I
10.1016/j.ijheatmasstransfer.2024.125633
中图分类号
O414.1 [热力学];
学科分类号
摘要
Despite the significant impact of the filling ratio on dry-out of heat pipe, current operating limit models do not adequately address this factor. This study proposes an advanced capillary limit model that incorporates the effect of the filling ratio. An experimental study was conducted to compare the operating limits of sodium heat pipes with filling ratios of 107 % and 246 %. The results showed that the existing capillary model is difficult to predict the operating limits based on filling ratios, leading to significant deviations between theoretical predictions and actual outcomes. Specifically, a heat pipe filled to 107 % experienced dry-out at a point 31.1 % lower than expected, while a heat pipe filled to 246 % reached dry-out at 20.2 % higher than expected. Notably, the overfilled heat pipe maintained a steady state even at 10.5 % above the expected dry out point. The key point of the proposed model, based on optical imaging and temperature data at dry-out, is that the excess liquid in vapor region travels and forms a liquid plug at the end of the condenser, which shortens the length required for capillary transport. Based on this insight, the Chi model was modified to predict the operating limit of overfilled heat pipes more accurately within a 5 % margin of error. The study highlights the critical role of filling ratio in heat pipe design, noting that overfilling can shorten the effective capillary length through liquid plug formation, thereby increasing the dry-out limit. However, these pools also limit the reach of sodium vapor and potentially reduce the effective area of the condenser.
引用
收藏
页数:16
相关论文
共 5 条
  • [1] A model of the capillary limit of a micro heat pipe and prediction of the dry-out length
    Suman, B
    De, S
    DasGupta, S
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2005, 26 (03) : 495 - 505
  • [2] Analysis of porous wick heat pipes, including capillary dry-out limitations
    Rice, Jeremy
    Faghri, Amir
    Proceedings of the ASME Heat Transfer Division 2005, Vol 1, 2005, 376-1 : 595 - 607
  • [3] Analysis of screen wick heat pipes, including capillary dry-out limitations
    Rice, Jeremy
    Fagh, Amir
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2007, 21 (03) : 475 - 486
  • [4] DRY-OUT PHENOMENA IN GRAVITY-ASSIST HEAT PIPES WITH CAPILLARY-FLOW
    BUSSE, CA
    KEMME, JE
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1980, 23 (05) : 643 - 654
  • [5] Effect of localized dry-out on startup and steady-state operation characteristics of ethanol-based oscillating heat pipes
    Ying, Liu
    Yan, Yuhao
    Bao, Kangli
    Wu, Xilei
    Yang, Jialiang
    Ning, Jiang
    Han, Xiaohong
    APPLIED THERMAL ENGINEERING, 2024, 257