Simulation of pre-cooling in a high pressure hydrogen refueling station for operation optimization

被引:0
|
作者
Yang, Xin [1 ]
Wang, Wen [1 ]
Wang, Zhao [2 ]
Ma, Fanhua [3 ]
机构
[1] School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai,200240, China
[2] Jiangsu Guofu Hydrogen Energy Equipment Co Ltd, Zhangjiagang,215600, China
[3] School of Vehicle and Mobility, Tsinghua University, Beijing,100084, China
关键词
Heat exchangers;
D O I
10.1016/j.ijhydene.2024.04.064
中图分类号
学科分类号
摘要
Pre-cooling for refueling high-pressure hydrogen not only avoids safety hazards but also extends the driving range of vehicles. In this paper, a simulation model for hydrogen refueling with a compact heat exchanger is developed to analyze the dynamic process in HRS with three-stage storage tanks. According to the simulated results, the hydrogen temperature at the heat exchanger's outlet is greatly influenced by the mass flow rate and the inlet temperature. The pre-cooling duration is a feasible method to save energy. Moreover, optimization discussions about the pre-cooling temperature and the pre-cooling duration have been carried out for the sake of the low final gas temperature, high SOC, and minimum energy consumption. If the ambient temperature decreases by 10 K, the optimal pre-cooling temperature could be adjusted to increase by 4 K. And if the initial vessel pressure increases by 2 MPa, the optimal pre-cooling duration could be shortened by 10 s. © 2024
引用
收藏
页码:434 / 444
相关论文
共 50 条
  • [21] Numerical analysis on pre-cooling processes of liquefied hydrogen tank
    Lee, Hyunseo
    Yun, Sungho
    Kim, Gildong
    Lee, Dongchan
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [22] Economic analysis of hydrogen refueling station considering different operation modes
    Wu, Ling
    Zhu, Zhentao
    Feng, Yi
    Tan, Wenyi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 52 : 1577 - 1591
  • [23] Simulation of pre-cooling of a liquefied natural gas storage tank
    Kuang, Yiwu
    Zhuan, Rui
    Wang, Wen
    Zhu, Juxiang
    Huagong Xuebao/CIESC Journal, 2015, 66 : 138 - 142
  • [24] The logistics route of a CNGV distribution station and operation simulation: SRM Bucharest refueling station
    Muresan, Constantin-Cristian
    Halafawi, Mohamed
    Dinu, Florinel
    Suditu, Silvian
    Stoicescu, Maria
    PETROLEUM SCIENCE AND TECHNOLOGY, 2024, 42 (04) : 491 - 513
  • [25] Development of efficient hydrogen refueling station by process optimization and control
    Xu, Zhuang
    Dong, Wenping
    Yang, Kang
    Zhao, Yuejing
    He, Guangli
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (56) : 23721 - 23730
  • [26] Numerical simulation of LNG unloading pipeline pre-cooling process
    Zhu, Xiaochun
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2016, 35 (02): : 383 - 388
  • [27] The 3-D Simulation of the LNGC in Pre-cooling Process
    Wang Zhongcheng
    Liu Xiaoyu
    Kan Ankang
    ADVANCED MATERIALS AND COMPUTER SCIENCE, PTS 1-3, 2011, 474-476 : 2146 - +
  • [28] New Technologies of Pressure Pre-cooling Flow Field Uniformity
    Niu, Jianhui
    Tian, Haichuan
    Qin, Junru
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 476 - 480
  • [29] Optimization and Analysis of an Integrated Liquefaction Process for Hydrogen and Natural Gas Utilizing Mixed Refrigerant Pre-Cooling
    Yan, Fengyuan
    Geng, Jinliang
    Rong, Guangxin
    Sun, Heng
    Zhang, Lei
    Li, Jinxu
    ENERGIES, 2023, 16 (10)
  • [30] Simulation analysis of temperature characteristics of the high-pressure hydrogen refueling process
    Yang X.
    Wang W.
    Xu K.
    Ma F.
    Huagong Xuebao/CIESC Journal, 2023, 74 : 280 - 286