Thermodynamic analysis of a solar powered ejector cooling system

被引:0
|
作者
Khennich, Mohammed [1 ]
Galanis, Nicolas [2 ]
Sorin, Mikhail [2 ]
Orfi, Jamel [3 ]
Sarrafi, Ahmadreza [1 ]
Dupuis, Serge [4 ]
机构
[1] Mechanical Engineering Department, Université de Moncton, Moncton,NB, Canada
[2] Mechanical Engineering Department, Université de Sherbrooke, Sherbrooke,QC, Canada
[3] Mechanical Engineering Department, King Saud University, Riyadh, Saudi Arabia
[4] Civil Engineering Department, Université de Moncton, Moncton,NB, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
Collector efficiency - Compressed air - Cooling systems - Ejectors (pumps) - Firedamp - Gas mixtures - Heat exchangers - Heat transfer performance - Industrial heating - Liquefied gases - Solar refrigeration;
D O I
10.1016/j.ijft.2024.100960
中图分类号
学科分类号
摘要
A steady-state model of an ejector cooling system activated by solar heat is presented and applied in response to the increasing demand of cooling in hot-climatic regions. The system comprises three loops connected by heat exchangers. The first loop, or collection sub-system, includes the solar collectors (both cylindrical-parabolic and flat plate collectors are modeled) and the heat transfer fluid (a thermal oil). The second loop also includes an ejector which uses polytropic efficiencies and provides the power necessary to circulate a second low-pressure stream of the refrigerant through the evaporator and an intermediate-pressure condenser. The third loop connects the load to the evaporator using ethylene glycol. In this study, the model is particularly based on the laws of classical and finite size thermodynamics and incorporates experimentally derived relations for the efficiency of the cylindrical-parabolic collectors as well as an ejector model which is based on physical laws rather than on refrigerant specific correlations used in previous studies. The results include a parametric study analysing the effect of the generator superheating and the calorific flow of the heat transfer fluid on the ejector dimensions and the overall system performance. The impact of the solar collector type on the collector surface and the system performance by a fixed incident radiation was investigated. The results illustrate that using parabolic trough collectors, the exergy efficiency of the entire system and the required collector's area are almost constant with the solar radiation intensity. They are approximately 35 % and 35 m2 respectively. It was also shown that further superheating the refrigerant by an additional 10 °C at the generator exit reduces the ejector's total length by 8.1 %, leading to positive economic impacts on raw material acquisition for the solar-powered ejector refrigeration system. Furthermore, doubling the calorific flow reduced the COP by half and increased the ejector length. The economic analysis of the system reveals two key findings: The largest portion of the initial costs is attributed to the solar collector, which is essential for providing the thermal energy required for the system's operation. The main hourly expense of the system is the electricity cost associated with powering the pumps. © 2024
引用
收藏
相关论文
共 50 条
  • [41] On the validity of a design method for a solar-assisted ejector cooling system
    Colle, S.
    Pereira, G. S.
    Vidal Gutierrez, H. R.
    Escobar Moragas, R.
    SOLAR ENERGY, 2009, 83 (02) : 139 - 149
  • [42] Ejector Configuration for Designing a Simple and High Performance Solar Cooling System
    Saito, Yusuke
    Ito, Tatsuya
    Matsuo, Akiko
    Sato, Haruki
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2564 - 2571
  • [43] Performance of a solar ejector cooling-system in the southern region of Turkey
    Ersoy, H. Kursad
    Yalcin, Sakir
    Yapici, Rafet
    Ozgoren, Muammer
    APPLIED ENERGY, 2007, 84 (09) : 971 - 983
  • [44] Solar-Powered Cooling System for Residential Building
    Yaakob, Y.
    Ibrahim, D.
    Awalludin, M. A.
    Moria, H.
    INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND GREEN TECHNOLOGY 2018, 2019, 268
  • [45] Thermodynamic modeling and sensitivity analysis of ejector in refrigeration system
    Liu, Jiapeng
    Wang, Lei
    Jia, Lei
    Wang, Xinli
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 : 485 - 492
  • [46] On the validaty of a design method to estimate the solar fraction for an ejector cooling system
    Colle, Sergio
    Pereira, Guilherme dos Santos
    Gutierrez, Humberto Ricardo Vidal
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 848 - 852
  • [47] Combined cooling and power system with solar-driven ejector refrigeration
    Xu Y.
    Wang H.
    Ge Z.
    Wang J.
    Xia Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (04): : 249 - 255
  • [48] Thermodynamic analysis of a refrigeration system with double evaporators and ejector
    Unal, Saban
    Erdinc, Mehmet Tahir
    Kutlu, Cagri
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2016, 31 (04): : 1039 - 1047
  • [49] Thermodynamic modeling and exergy analysis of a solar adsorption cooling system with cooling tower in Mediterranean conditions
    Koronaki, I. P.
    Papoutsis, E. G.
    Papaefthimiou, V. D.
    APPLIED THERMAL ENGINEERING, 2016, 99 : 1027 - 1038
  • [50] An irreversible-thermodynamic model for solar-powered absorption cooling systems
    Wijeysundera, NE
    SOLAR ENERGY, 2000, 68 (01) : 69 - 75