In this study, a new method is proposed for developing an effective calibration object by using commonly available papers. The proposed method uses a pyramid-shaped solid paper as a calibration object for foot scanners with two sensors. The design of this calibration object allows simultaneous scanning of its inner and outer surfaces. The three-dimensional (3D) shape information collected from the two sensors is used to derive an initial 3D transformation relationship between the two sensors. Next, the intersections between the four facets of the pyramid-shaped object are used in conjunction with a minimization algorithm to improve the precision of the 3D transformation relationship. The proposed method is applied to an actual foot scanning system to calibrate the upper and lower 3D sensors of the foot scanner, and the 3D model is reconstructed. The performance of this method is verified by comparing the reconstructed models with ground truth models. The calibration error between the two sensors was less than 0.6 mm on average when using the proposed calibration method. The proposed method offers the advantage of simple operation as it uses a single sheet of paper, thus avoiding the difficulties encountered in conventional calibration methods. © ICROS 2023.
引用
收藏
页码:380 / 389
页数:9
相关论文
共 50 条
  • [41] Comparing 3D foot scanning with conventional measurement methods
    Lee, Yu-Chi
    Lin, Gloria
    Wang, Mao-Jiun J.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2014, 7
  • [42] Extrinsic Calibration for a Modular 3D Scanning Quality Validation Platform with a 3D Checkerboard
    Kaiser, Mirko
    Brusa, Tobia
    Bertsch, Martin
    Wyss, Marco
    Cukovic, Sasa
    Meixner, Gerrit
    Koch, Volker M.
    SENSORS, 2024, 24 (05)
  • [43] Mutual Calibration of Sensors for Multispectral 3D Scanning of Surface
    Chromy, Adam
    2017 9TH INTERNATIONAL CONGRESS ON ULTRA MODERN TELECOMMUNICATIONS AND CONTROL SYSTEMS AND WORKSHOPS (ICUMT), 2017, : 199 - 204
  • [44] ANALYSIS OF METHODS FOR CAMERA CALIBRATION IN 3D SCANNING SYSTEMS
    Suriansky, Jozef
    Cmarada, Michal
    ANNALS OF DAAAM FOR 2012 & PROCEEDINGS OF THE 23RD INTERNATIONAL DAAAM SYMPOSIUM - INTELLIGENT MANUFACTURING AND AUTOMATION - FOCUS ON SUSTAINABILITY, 2012, 23 : 365 - 368
  • [45] Analysis of Object Deformations Printed by Extrusion of Concrete Mixtures Using 3D Scanning
    Mendricky, Radomir
    Keller, Petr
    BUILDINGS, 2023, 13 (01)
  • [46] A Dynamic 3D Foot Reconstruction System
    Thabet, Ali K.
    Trucco, Emanuele
    Salvi, Joaquim
    Wang, Weijie
    Abboud, Rami J.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 599 - 602
  • [47] CREATING THE SOLID 3D MODEL OF A BUILDING USING LASER SCANNING TECHNOLOGY
    Mihai, Doru
    Marinescu, Catalin Ciprian
    SCIENTIFIC PAPERS-SERIES E-LAND RECLAMATION EARTH OBSERVATION & SURVEYING ENVIRONMENTAL ENGINEERING, 2014, 3 : 111 - 114
  • [48] A prototype system for 3D measurement using flexible calibration method
    Fukuda, Masanori
    Miyasaka, Takeo
    Araki, Kazuo
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS VII, 2006, 6056
  • [49] 3D OBJECT MATCHING BASED ON SPHERICAL HILBERT SCANNING
    Tong, Can
    Kamata, Sei-ichiro
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 2941 - 2944
  • [50] Losing our Senses, an Exploration of 3D Object Scanning
    Eve, Stuart
    OPEN ARCHAEOLOGY, 2018, 4 (01): : 114 - 122