Optimization of a large aperture wedge prism support system based on the closed-loop structural-thermal-optical performance method

被引:0
|
作者
Wen, Wansha [1 ,2 ]
Ruan, Ping [1 ,2 ]
Li, Baopeng [1 ]
Lv, Tao [1 ,2 ]
机构
[1] Chinese Acad Sci, Xian Inst Opt & Precis Mech, 17 Xinxi Rd, Xian 710119, Peoples R China
[2] Chinese Acad Sci, Key Lab Space Precis Measurement Technol, 17 Xinxi Rd, Xian 710119, Peoples R China
来源
OPTICS EXPRESS | 2024年 / 32卷 / 23期
基金
中国国家自然科学基金;
关键词
DESIGN;
D O I
10.1364/OE.540266
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the instrument suite of the Thirty Meter Telescope (TMT), the linear atmospheric dispersion corrector (LADC) is positioned at the forefront of the spectrometer to mitigate atmospheric dispersion. The LADC comprises two large aperture wedge prisms, each approximately 1.5 meters in diameter. These prisms, which are transmissive optical elements, are supported radially along their outer circumferences. However, due to the rotational asymmetry of the prisms relative to the optical axis, the support forces do not align with the plane of the center of gravity, leading to a bending moment caused by gravitational and reaction forces. This misalignment results in significant deformation of the prism surfaces. The structural-thermaloptical performance integrated model method is typically employed to evaluate the impact of the support system on prism surface deformation. This process often involves extensive manual iterations and operates in an open-loop manner, making it inefficient and heavily reliant on the analyst's expertise. To address these limitations, this paper proposes a closed-loop integrated interface programs between analysis tools and applying advanced optimization algorithms, the traditional open-loop integrated model analysis process is transformed into a closed-loop system, enabling more efficient and reliable optimization. The closed-loop integrated model method incorporates Optimal Latin Hypercube Design (Opt LHD) and Particle Swarm Optimization (PSO) algorithms to optimize the prism support structure, reducing the analysis time from one week to just two days. Compared to the original support structure, the root mean square (RMS) value of optical surface deformation decreased by 49.3%, from 155.0 nm to 78.6 nm, under gravity and 2 degrees C temperature coupled conditions; and by 62.5%, from 289. 1 nm to 108. 4 nm, under gravity and 42 degrees C temperature coupled conditions. These results demonstrate that the closed-loop integrated model optimization method not only improves efficiency but also achieves significantly better outcomes.
引用
收藏
页码:40453 / 40466
页数:14
相关论文
共 50 条
  • [21] Integrating topology optimization in precision motion system design for optimal closed-loop control performance
    van der Veen, Gijs
    Langelaar, Matthijs
    van der Meulen, Stan
    Laro, Dick
    Aangenent, Wouter
    van Keulen, Fred
    MECHATRONICS, 2017, 47 : 1 - 13
  • [22] Thermal behavior prediction and adaptation analysis of a reelwell drilling method for closed-loop geothermal system
    Yang, Hongwei
    Li, Jun
    Zhang, Hui
    Jiang, Jiwei
    Guo, Boyun
    Gao, Reyu
    Zhang, Geng
    Applied Energy, 2022, 320
  • [23] Thermal behavior prediction and adaptation analysis of a reelwell drilling method for closed-loop geothermal system
    Yang, Hongwei
    Li, Jun
    Zhang, Hui
    Jiang, Jiwei
    Guo, Boyun
    Gao, Reyu
    Zhang, Geng
    APPLIED ENERGY, 2022, 320
  • [24] Optimization of a closed-loop gas system for the operation of Resistive Plate Chambers at the Large Hadron Collider experiments
    Capeans, M.
    Glushkov, I.
    Guida, R.
    Hahn, F.
    Haider, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 : S214 - S221
  • [25] A fuzzy/logic based decision support system for low-flow/closed-loop anaesthesia
    Hooper, B
    Hu, XH
    Jaros, G
    Baker, B
    PROCEEDINGS OF THE SIXTH IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS, VOLS I - III, 1997, : 1615 - 1620
  • [26] A PSO-Based Recurrent Closed-Loop Optimization Method for Multiple Controller Single-Output Thermal Engineering Systems
    Liu, Xingjian
    Pan, Lei
    PROCESSES, 2019, 7 (11)
  • [27] A New Reliability Analysis Method based on Stability Reliability for Closed-Loop Control System
    Guo Xiao-he
    Jiao Zong-xia
    Wang Shao-ping
    ADVANCES IN PRODUCT DEVELOPMENT AND RELIABILITY III, 2012, 544 : 115 - 120
  • [28] Model optimization identification method based on closed-loop operation data and process characteristics parameters
    Geng, Zhiqiang
    Li, Runxue
    Gu, Xiangbai
    Sensors and Transducers, 2014, 163 (01): : 1 - 8
  • [29] Reliability Analysis of Repairable System with Multiple Closed-Loop Feedbacks Based on GO Method
    Mu H.
    Cui Y.
    Hou X.
    Yi X.
    Ma W.
    Liu W.
    Journal of Beijing Institute of Technology (English Edition), 2022, 31 (04): : 431 - 440
  • [30] Reliability Analysis of Repairable System with Multiple Closed-Loop Feedbacks Based on GO Method
    Huina Mu
    Yuhang Cui
    Xinrong Hou
    Xiaojian Yi
    Wentao Ma
    Wei Liu
    JournalofBeijingInstituteofTechnology, 2022, 31 (04) : 431 - 440